Zhang Dong

Dr. Zhang Dong


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ZDZhang Dong
Zhang Dong
LYLiyin Yuan
Liyin Yuan
SWShengwei Wang
Shengwei Wang
HYHongxuan Yu
Hongxuan Yu
CZChangxing Zhang
Changxing Zhang
Yueming WangYueming Wang
Yueming Wang
Wide Swath and High Resolution Airborne Pushbroom Hyperspectral Imager (WiSHiRaPHI) is the new-generation airborne hyperspectral imager instrument of China, aimed at acquiring accurate spectral curve of target on the ground with both high spatial resolution and high spectral resolution. The spectral sampling interval of WiSHiRaPHI is 2.4 nm and the spectral resolution is 3.5 nm (FWHM), integrating 256 channels coving from 400 nm to 1000 nm. The instrument has a 40-degree field of view (FOV), 0.125 mrad instantaneous field of view (IFOV) and can work in high spectral resolution mode, high spatial resolution mode and high sensitivity mode for different applications, which can adapt to the Velocity to Height Ratio (VHR) lower than 0.04. The integration has been finished, and several airborne flight validation experiments have been conducted. The results showed the system’s excellent performance and high efficiency.

16 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
HLHonglin Liu
Honglin Liu
ZDZhang Dong
Zhang Dong
Yueming WangYueming Wang
Yueming Wang
Due to the strong absorption of water vapor at wavelengths of 1350–1420 nm and 1820–1940 nm, under normal atmospheric conditions, the actual digital number (DN) response curve of a hyperspectral imager deviates from the Gaussian shape, which leads to a decrease in the calibration accuracy of an instrument’s spectral response functions (SRF). The higher the calibration uncertainty of SRF, the worse the retrieval accuracy of the spectral characteristics of the targets. In this paper, an improved spectral calibration method based on a monochromator and the spectral absorptive characteristics of water vapor in the laboratory is presented. The water vapor spectral calibration method (WVSCM) uses the difference function to calculate the intrinsic DN response functions of the spectral channels located in the absorptive wavelength range of water vapor and corrects the wavelength offset of the monochromator via the least-square procedure to achieve spectral calibration throughout the full spectral responsive range of the hyper-spectrometer. The absolute spectral calibration uncertainty is ±0.125 nm. We validated the effectiveness of the WVSCM with two tunable semiconductor lasers, and the spectral wavelength positions calibrated by lasers and the WVSCM showed a good degree of consistency.

26 August 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YWYin Wu
Yin Wu
MWMaoXing Wen
MaoXing Wen
ZDZhang Dong
Zhang Dong
YYYi Yao
Yi Yao
CZChangxing Zhang
Changxing Zhang
Yueming WangYueming Wang
Yueming Wang
Visible–near-infrared (VNIR) hyperspectral imaging provides a non-contact approach for cultural heritage examination. This study presents the design and calibration of a compact finite-conjugate VNIR pushbroom hyperspectral camera for close-range mural imaging. Operating over 400–1000 nm at a nominal working distance of 404 mm, the system provides a mean spectral sampling interval of 4.85 nm and an object-space sampling interval of approximately 82.4 μm/pixel. An integrated calibration workflow was established for wavelength assignment, spectral response characterization, geometric correction, radiometric calibration, and scan synchronization. The experimental results yielded a modulation transfer function (MTF) of 0.34 at the effective detector Nyquist frequency, a mean spectral response function full width at half maximum (FWHM) of 6.3 nm, a maximum absolute wavelength residual below 0.90 nm, residual smile and keystone errors below 0.3 pixels, a residual radiometric nonuniformity of 0.71%, and a mean signal-to-noise ratio (SNR) of 339. Measurements of Potala Palace mural samples demonstrate the acquisition of spatially detailed, radiometrically corrected hyperspectral data under close-range conditions.