Background: A novel flash glucose monitoring system (FGMS) (FreeStyle Libre, Abbott, UK) was recently developed for humans. It continuously measures the interstitial glucose (IG) concentrations for 14 days. Objectives: To assess the clinical and analytical accuracy of the FGMS in diabetic dogs. Animals: Ten client-owned diabetic dogs on insulin treatment. Methods: Prospective and observational study. The FGMS was placed on the neck for up to 14 days. During the 1st–2nd, 6–7th, and 13–14th days from application, the IG measurements were compared with the plasma (EDTA) glucose (PG) concentrations analyzed by a reference hexokinase based method. Results: The application and the use of the FGMS were apparently painless, easy, and well tolerated by all dogs. Mild erythema at the site of the application was found in 5/10 dogs at the end of the wearing period. A good correlation between IG and PG concentrations (rho = 0.94; P < .001) was found. The FGMS was 93, 99, and 99% accurate at low, normal, and high blood glucose concentrations. Mean ± standard deviation difference from the reference method was 2.3 ± 46.8 mg/dL. Conclusion and clinical importance: The FGMS is easy to use and is accurate for IG glucose measurement in diabetic dogs.
Background A factory‐calibrated flash glucose monitoring system (FGMS; FreeStyle Libre) recently was evaluated in dogs with uncomplicated diabetes mellitus. It is not known if this system is reliable during diabetic ketoacidosis (DKA). Objectives To assess the performance of the FGMS in dogs with DKA and to determine the effect of severity of ketosis and acidosis, lactate concentration, body condition score (BCS), and time wearing the sensor on the accuracy of the device. Animals Fourteen client‐owned dogs with DKA. Methods The interstitial glucose (IG) measurements were compared with blood glucose (BG) measurements obtained using a validated portable glucometer. The influence of changes in metabolic variables (β‐hydroxybutyrate, pH, bicarbonate, and lactate) and the effect of BCS and time wearing on sensor performance were evaluated. Accuracy was determined by fulfillment of ISO15197:2013 criteria. Results Metabolic variables, BCS, and time wearing were not associated with the accuracy of the sensor. Good agreement between IG measurements and BG was obtained both before and after DKA resolution (r = .88 and r = .93, respectively). Analytical accuracy was not achieved, whereas clinical accuracy was demonstrated with 100% and 99.6% of results in zones A + B of the Parkes consensus error grid analysis before and after DKA resolution, respectively. Conclusions and Clinical Importance Changes in metabolic variables, BCS, and time wearing do not seem to affect agreement between IG and BG. Despite not fulfilling the ISO requirements, the FGMS provides clinically accurate estimates of BG in dogs with DKA.
30 October 2020 in Journal of Veterinary Internal Medicine
Background: Flash glucose monitoring system (FGMS; FreeStyle Libre) was recently validated for use in diabetic dogs (DD). It is not known if this system is clinically useful in monitoring DD. Objective: To compare the clinical utility of FGMS against blood glucose curves (BGCs) obtained with a portable blood glucose meter (PBGM) in monitoring DD. Animals: Twenty dogs with diabetes mellitus. Methods: Prospective study. Dogs with diabetes mellitus on insulin treatment for at least 1 month were included. Comparisons of insulin dose recommendations based on the in-hospital GCs acquired using FGMS and a PBGM, consecutive-day interstitial GCs (IGCs) acquired at home using the FGMS, and consecutive-day, home vs hospital IGCs acquired using the FGMS were made using concordance analysis. Results: There was good concordance between insulin dose recommendations based on FGMS and PBGM generated GCs and IGCs obtained in the 2 different environments on 2 consecutive days, but almost absent concordance between IGCs obtained on 2 consecutive days at home. Glucose nadirs were detected in 34/43 (79%) of Ambulatory Glucose Profile (AGP) reports of the FGMS. In comparison, concordant glucose nadirs were identified in 14/34 (41%) BGCs using PBGM. The individual FGMS scans and PBGM identified 60% and 9% of low IG/hypoglycemic episodes, respectively. Conclusions and Clinical Importance: Insulin dose adjustments based on BGCs can be suboptimal. The FGMS allows a more accurate identification of the glucose nadirs and hypoglycemic episodes compared to the use of a PBGM and assessment of day-to-day variations in glycemic control.
23 February 2021 in Journal of Veterinary Internal Medicine
Background: Successful treatment of cats with hypersomatotropism by transsphenoidal hypophysectomy is described in small numbers of cats. Objectives: To describe the endocrine profile, survival, and remission rates of hypersomatotropism and diabetes mellitus in a cohort of cats with hypersomatotropism that underwent hypophysectomy between 2008 and 2020. Animals: Twenty-five client-owned cats with spontaneous hypersomatotropism. Methods: Retrospective study. Diagnosis of hypersomatotropism was based on clinical signs, plasma insulin-like growth factor-1 (IGF-1) concentration, and imaging of the pituitary gland. Growth hormone (GH) and IGF-1 concentrations were measured repeatedly after surgery. Survival times were calculated based on follow-up information from owners and referring veterinarians. Results: Median postoperative hospital stay was 7 days (range, 3-18 days). One cat died within 4 weeks of surgery. Median plasma GH concentration decreased significantly from 51.0 ng/mL (range, 5.0-101.0 ng/mL) before surgery to 3.8 ng/mL (range, 0.6-13.0 ng/mL) at 5 hours after surgery. Remission of hypersomatotropism, defined as normalization of plasma IGF-1 concentration, occurred in 23/24 cats (median, 34 ng/mL; range, 14-240 ng/mL) and 22/24 cats entered diabetic remission. Median survival time was 1347 days (95% confidence interval, 900-1794 days; range, 11-3180 days) and the overall 1-, 2-, and 3-year all-cause survival rates were 76%, 76%, and 52%, respectively. Conclusions and Clinical Importance: This study shows the beneficial outcome of hypophysectomy in cats with hypersomatotropism, marked by low death rate and a high percentage of diabetic remission and definitive cure.
1 May 2021 in Journal of Veterinary Internal Medicine
Background The FreeStyle Libre (Abbott Laboratories) is a flash glucose monitoring system (FGMS) that measures interstitial glucose concentration (IG). The system is factory-calibrated, easy to use, inexpensive, and could be useful for monitoring diabetic cats. Objectives To evaluate the analytical and clinical accuracy of the FGMS in cats and establish the lag-time between IG and blood glucose concentration (BG). Animals Twenty client-owned diabetic cats and 7 purpose-bred healthy cats. Methods Prospective study. Blood glucose concentration was measured using a portable glucose meter validated for use in cats that served as a reference method for IG, as measured by FGMS. In diabetic cats, data were collected for sensor wearing time with different methods of application and accuracy across glycemic ranges. Accuracy was determined by fulfillment of ISO15197:2013 criteria. In healthy cats, lag-time between IG and BG was established after IV administration of exogenous glucose. Results Good agreement between IG and BG was obtained (r = .93). Analytical accuracy was not achieved, whereas clinical accuracy was demonstrated with 100% of the results in zones A + B of the Parkes consensus error grid analysis. In the immediate 30 minutes after an IV bolus of glucose, when BG was increasing rapidly (approximately 2%/min), IG increased slowly, resulting in a difference of as much as 579 mg/dL, and no positive correlation between BG and IG was found. Conclusions and Clinical Importance The FGMS did not fulfill ISO requirements but is sufficiently accurate for glucose monitoring in cats, while considering the lag between IG and BG during periods of rapid changes in BG.