Alicja Wiora

Dr. Alicja Wiora

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2020 in Symmetry
Verified
Journal Article
Open access
PDF file
JWJózef Wiora
Józef Wiora
AWAlicja Wiora
Alicja Wiora
Fractional-order (FO) differential equations are more and more frequently applied to describe real-world applications or models of phenomena. Despite such models exhibiting high flexibility and good fits to experimental data, they introduce their inherent inaccuracy related to the order of approximation. This article shows that the chosen model influences the dynamic properties of signals. First, we calculated symbolically the steady-state values of an FO inertia using three variants of the Oustaloup filter approximation. Then, we showed how the models influence the Nyquist plots in the frequency domain. The unit step responses calculated using different models also have different plots. An example of FO control system evidenced different trajectories dependent on applied models. We concluded that publicized parameters of FO models should also consist of the name of the model used in calculations in order to correctly reproduce described phenomena. For this reason, the inappropriate use of FO models may lead to drawing incorrect conclusions about the described system.

12 June 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JWJózef Wiora
Józef Wiora
AWAlicja Wiora
Alicja Wiora
An assessment of measurement uncertainty is a task, which has to be the final step of every chemical assay. Apart from a commonly applied typical assessment method, Monte Carlo (MC) simulations may be used. The simulations are frequently performed by a computer program, which has to be written, and therefore some programming skills are required. It is also possible to use a commonly known spreadsheet and perform such simulations without writing any code. Commercial programs dedicated for the purpose are also available. In order to show the advantages and disadvantages of the ways of uncertainty evaluation, i.e., the typical method, the MC method implemented in a program and in a spreadsheet, and commercial programs, a case of pH measurement after two-point calibration is considered in this article. The ways differ in the required mathematical transformations, degrees of software usage, the time spent for the uncertainty calculations, and cost of software. Since analysts may have different mathematical and coding skills and practice, it is impossible to point out the best way of uncertainty assessment—all of them are just as good and give comparable assessments.

23 November 2018 in Sensors
Verified
Journal Article
Open access
PDF file
AWAlicja Wiora
Alicja Wiora
JWJózef Wiora
Józef Wiora
Glass pH electrodes are still successfully applied in the chemical and environmental industry. During their long-term use, periodic calibration is required to maintain the required accuracy of measurements because the parameters of the electrodes change over time. This work presents an aging of 11 pH electrodes within approximately 600 days in tap water. During this period, potentials of all electrodes in five buffer solutions were measured 44 times. This allowed determining the aging models of the electrodes. Models in other mediums might be different. Changes in slope, standard potential, hysteresis, and linearity of the characteristics were the objects of observations. A method for predicting electrode parameters is proposed. Furthermore, the procedure for estimating the uncertainty of pH measurements considering the aging of the electrodes is described. As a result of this work, a model of the aging process of pH electrodes in tap water can be constructed and subsequently, the measurement accuracy in the periods between calibrations can be improved.

22 June 2012 in Talanta
Verified
Journal Article
Closed access
AKAndrzej Kozyra
Andrzej Kozyra
JWJózef Wiora
Józef Wiora
AWAlicja Wiora
Alicja Wiora


30 October 2006 in Proceedings of SPIE
Verified
Conference Paper
Closed access
PDF file
JWJózef Wiora
Józef Wiora
AWAlicja Wiora
Alicja Wiora
The plot of ion-selective electrode's potential vs. ion concentration in a solution is non-linear and very complex. In the paper, a set-up is described which allows to determine the plot using multiple dilution method in an automatic way. The set-up is not expensive and the presence of experimenter in the laboratory is not necessary during the test of the electrode. Additionally, the system allows for simultaneous investigation of several electrodes.