Different types of corrosion may arise in steel reinforcement, such as general corrosion, pitting corrosion, hydrogen embrittlement, stress corrosion cracking and corrosion fatigue. However, corrosion of steel reinforcement in reinforced concrete (RC) structures can be classified into two categories: general (uniform) corrosion and pitting (localised) corrosion. In general, concrete researchers use uniform corrosion to study the effect of corrosion on RC structures. This approach is not accurate for concrete structures subjected to chloride attack, which usually experiences pitting corrosion. This paper describes an accelerated corrosion test used to obtain statistical parameters of maximum pit-depths distribution of corroded steel in a RC structure. Using probabilistic analysis, these statistical parameters are combined with statistical parameters of RC beams (i.e. beam dimensions, concrete strength, steel yield strength, cover thickness, workmanship quality, in situ strength factor, model error for flexure and shear and also corrosion rate) to determine the effect of corrosion on flexural and shear strength of RC beams. Using the proposed pitting corrosion model improves service life prediction of RC structures in a chloride environment.
The present paper describes accelerated corrosion test results and the development of a probabilistic model to predict the depth and variability of pitting for pretensioned prestressing wires and strands subject to pitting corrosion. From the accelerated corrosion tests in a chloride-concrete environment the mode of wire failure is studied, and the spatial distribution of maximum pit depth along wires for various lengths is obtained. The analysis shows that the maximum pit-depth distribution of prestressing wires can be represented by the Gumbel extreme value distribution. This model can be extended to predict the distribution of maximum pit depth for any length of wire, corrosion rate and time of exposure in real concrete structures. This information can be used to predict minimum cross-sectional area of a corroded wire, wire capacity and the effect of pitting corrosion on the safety of pretensioned prestressed concrete structures.
This paper deals with the behavior of a geopolymer concrete beam (GCB) under shear load using high calcium content fly ash (FA). The effect of the marine environment on the shear strength of GCB was considered by curing the specimen in a sea splashing zone for 28 days. Destructive and non-destructive tests were carried out to determine the properties of geopolymer concrete in different curing environments. Geopolymer concretes cured at room temperature showed higher compressive strength, slightly lower porosity, and higher concrete resistivity than that of those cured in sea water. From the loading test of the GCB under shear load, there was no effect of a sea environment on the crack pattern and crack development of the beam. The shear strength of the GCB generally exceeded the predicted shear strength based on the American Concrete Institute (ACI) Code.
30 November 2016 in The Open Civil Engineering Journal
This paper presents a study of the flexural strength of geopolymer concrete beam using high calcium content fly ash (FA) in marine environment, without high heat curing. Two series of beam specimens were loaded to failure to study the effect of chloride environment on the flexural strength of geopolymer concrete beams. Series I specimens were subjected to sea environment, whereas series II were kept at room temperature. Tests performed on concrete cylinders show that the sea water has no effect on compressive and splitting tensile stress of high calcium content FA based geopolymer concrete. However, the ratio of splitting and compressive strength for both series was approximately 44%, almost double than that of normal concrete. In addition, the flexural test of concrete beams shows that the average cracking load for series I specimens was 275% higher than that of series II. However, the ultimate load, crack pattern and deflection characteristic for both series were very similar.