Ilya Astrouski

Dr. Ilya Astrouski

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Applied Thermal Engineering
Verified
Journal Article
Closed access
IKIvo Krásný
Ivo Krásný
IAIlya Astrouski
Ilya Astrouski
MRMiroslav Raudenský
Miroslav Raudenský

1 February 2017 in Applied Thermal Engineering
Verified
Journal Article
Closed access
MRMiroslav Raudenský
Miroslav Raudenský
IAIlya Astrouski
Ilya Astrouski
MDMiroslav Dohnal
Miroslav Dohnal

6 April 2021 in Polymers
Verified
Journal Article
Open access
PDF file
TKTereza Kroulikova
Tereza Kroulikova
TKTereza Kudelova
Tereza Kudelova
Erik BartuliErik Bartuli
Erik Bartuli
Jan VančuraJan Vančura
Jan Vančura
IAIlya Astrouski
Ilya Astrouski
A novel heat exchanger for automotive applications developed by the Heat Transfer and Fluid Flow Laboratory at the Brno University of Technology, Czech Republic, is compared with a conventional commercially available metal radiator. The heat transfer surface of this heat exchanger is composed of polymeric hollow fibers made from polyamide 612 by DuPont (Zytel LC6159). The cross-section of the polymeric radiator is identical to the aluminum radiator (louvered fins on flat tubes) in a Skoda Octavia and measures 720 × 480 mm. The goal of the study is to compare the functionality and performance parameters of both radiators based on the results of tests in a calibrated air wind tunnel. During testing, both heat exchangers were tested in conventional conditions used for car radiators with different air flow and coolant (50% ethylene glycol) rates. The polymeric hollow fiber heat exchanger demonstrated about 20% higher thermal performance for the same air flow. The efficiency of the polymeric radiator was in the range 80–93% and the efficiency of the aluminum radiator was in the range 64–84%. The polymeric radiator is 30% lighter than its conventional metal competitor. Both tested radiators had very similar pressure loss on the liquid side, but the polymeric radiator featured higher air pressure loss.

1 April 2016 in Applied Solar Energy
Verified
Journal Article
Closed access
PDF file
MSMichaela Schmidt
Michaela Schmidt
IAIlya Astrouski
Ilya Astrouski
MRMarcus Reppich
Marcus Reppich
MRMiroslav Raudensky
Miroslav Raudensky

2 November 2020 in Materials
Verified
Journal Article
Open access
PDF file
IAIlya Astrouski
Ilya Astrouski
HBHana Bellerova
Hana Bellerova
TKTereza Kudelova
Tereza Kudelova
TKTereza Kroulikova
Tereza Kroulikova
Currently, liquid-to-gas heat exchangers in buildings, domestic appliances and the automotive industry are mainly made of copper and aluminum. Using plastic instead of metal can be very beneficial from an economic and environmental point of view. However, it is required that a successful plastic design meets all the requirements of metal heat exchangers. The polymeric hollow fiber heat exchanger studied in this work is completive to common metal finned heat exchangers. Due to its unique design (the use of thousands of thin-walled microtubes connected in parallel), it achieves a high level of compactness and thermal performance, low pressure drops and high operation pressure. This paper focuses on an important aspect of heat exchanger operation—its fouling in conditions relevant to building and domestic application. In heating, ventilation and air conditioning (HVAC) and automotive and domestic appliances, outdoor and domestic dust are the main source of fouling. In this study, a heat exchanger made of polymeric hollow fibers was tested in conditions typical for indoor HVAC equipment, namely with the 20 °C room air flowing through the hot water coil (water inlet 50 °C) with air velocity of 1.5 m/s. ASHRAE test dust was used as a foulant to model domestic dust. A polymeric heat exchanger with fibers with an outer diameter of 0.6 mm (1960 fibers arranged into 14 layers in total) and a heat transfer area of 0.89 m2 was tested. It was proven that the smooth polypropylene surface of hollow fibers has a favorable antifouling characteristic. Fouling evolution on the metallic heat transfer surfaces of a similar surface density was about twice as quick as on the plastic one. The experimental results on the plastic heat exchanger showed a 38% decrease in the heat transfer rate and a 91% increase in pressure drops after eighteen days of the experiment when a total of 4000 g/m2 of the test dust had been injected into the air duct. The decrease in the heat transfer rate of the heat exchanger was influenced mainly by clogging in the frontal area because the first layers were fouled significantly more than the deeper layers.

1 August 2021 in Energy
Verified
Journal Article
Closed access
JBJan Bohacek
Jan Bohacek
HBHana Bellerova
Hana Bellerova
IAIlya Astrouski
Ilya Astrouski
EKEbrahim Karimi-Sibaki
Ebrahim Karimi-Sibaki