Shengbai Xie

Dr. Shengbai Xie


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

30 May 2017 in Boundary-Layer Meteorology
Verified
Journal Article
Closed access
PDF file
SXShengbai Xie
Shengbai Xie
CACristina Archer
Cristina Archer

3 February 2021 in Wind Energy
Verified
Journal Article
Open access
PDF file
SXShengbai Xie
Shengbai Xie
A new approach is proposed to do the velocity sampling for actuator‐line models (ALM). Unlike the conventional spatial averaging approaches, the velocity sampling is performed in a Lagrangian averaging way along flow paths with a time scale depending on the local flow patterns. The new approach is evaluated by large‐eddy simulations of a utility‐scale National Renewable Energy Laboratory (NREL)‐5MW wind turbine. The results show that the Lagrangian approach of velocity sampling is effective to reduce the spurious numerical oscillations in the modeling results. The good match with the benchmark data indicates that correct free upwind velocity can be obtained with a careful determination of the associated time scale. Also, a piecewise function is proposed to replace the Gaussian function for the force projection process.

2 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
Ihor ShchurIhor Shchur
Ihor Shchur
VKVolodymyr Klymko
Volodymyr Klymko
SXShengbai Xie
Shengbai Xie
DSDavid Schmidt
David Schmidt
In this paper, dual-rotor counter-rotating (CR) configurations of vertical axis wind turbines (VAWTs) are briefly inspected and divided into three types. This investigation was focused on one of these types—the CR-VAWT with co-axial rotors, in which two equal rotors are placed on the same shaft, displaced from each other along it and rotated in opposite directions. For this CR-VAWT with three-blade H-Darrieus rotors, the properties of the design in terms of aerodynamics, mechanical transmission and electric generator, as well as control system, are analyzed. A new direct-driven dual-rotor permanent magnet synchronous generator was proposed, in which two built-in low-power PM electric machines have been added. They perform two functions—starting-up and overclocking of the rotors to the angular velocity at which the lifting force of the blades is generated, and stabilizing the CR-VAWT work as wind gusts act on the two rotors. Detailed in this paper is the evaluation of the aerodynamic performance of the CR-VAWT via 3D computational fluid dynamics simulations. The evaluation was conducted using the CONVERGE CFD software with the inclusion of the actuator line model for the rotor aerodynamics, which significantly reduces the computational effort. Obtained results show that both rotors, while they rotate in opposite directions, had a positive impact on each other. At the optimal distance between the rotors of 0.3 from a rotor height, the power coefficients of the upper and lower rotors in the CR-VAWT increased, respectively, by 5.5% and 13.3% simultaneously with some increase in their optimal tip-speed ratio compared to the single-rotor VAWT.

17 December 2024 in Wind Energy
Verified
Journal Article
Open access
HDHannah Darling
Hannah Darling
DSDavid Schmidt
David Schmidt
SXShengbai Xie
Shengbai Xie
JSJasim Sadique
Jasim Sadique
AKArjen Koop
Arjen Koop
TTThanh Toan Tran
Thanh Toan Tran
With only a few floating offshore wind turbine (FOWT) farms deployed anywhere in the world, FOWT technology is still in its infancy, building on a modicum of real‐world experience to advance the nascent industry. To support further development, engineers rely heavily on modeling tools to accurately portray the behavior of these complex systems under realistic environmental conditions. This reliance creates a need for verification and validation of such tools to improve reliability of load and dynamic response prediction and analysis capabilities of FOWT systems. The Offshore Code Comparison Collaboration, Continued with Correlation and unCertainty (OC6) project was created under the framework of the International Energy Agency to address this need and considers a three‐sided verification and validation between engineering level models, computational fluid dynamics (CFD), and experimental results. In this paper, a novel floating offshore wind platform, the Stiesdal TetraSpar, is simulated using CFD under the load conditions defined by Phase IV of the OC6 project. The comparison of these CFD results against the experimental results demonstrated the ability to predict the platform response to waves when imposing the measured wave signals as input. Although validation versus experiment was largely successful, the damping behavior was impacted by uncertainties likely originating from the mooring system and sensor umbilical cable. This extensive comparison effort with multiple CFD practitioners offers insight into best practices to achieve reliable results.