While modern low-power microcontrollers are a cornerstone of wearable physiological sensors, their limited on-chip storage typically makes peripheral storage devices a requirement for long-term physiological sensing—significantly increasing both size and power consumption. Here, a wearable biosensor system capable of long-term recording of physiological signals using a single, 64 kB microcontroller to minimize sensor size and improve energy performance is described. Electrodermal (EDA) signals were sampled and compressed using a multiresolution wavelet transformation to achieve long-term storage within the limited memory of a 16-bit microcontroller. The distortion of the compressed signal and errors in extracting common EDA features is evaluated across 253 independent EDA signals acquired from human volunteers. At a compression ratio (CR) of 23.3×, the root mean square error (RMSErr) is below 0.016 S and the percent root-mean-square difference (PRD) is below 1%. Tonic EDA features are preserved at a CR = 23.3× while phasic EDA features are more prone to reconstruction errors at CRs > 8.8×. This compression method is shown to be competitive with other compressive sensing-based approaches for EDA measurement while enabling on-board access to raw EDA data and efficient signal reconstructions. The system and compression method provided improves the functionality of low-resource microcontrollers by limiting the need for external memory devices and wireless connectivity to advance the miniaturization of wearable biosensors for mobile applications.
This study presents an ultra-low resource platform for physiological sensing that uses on-chip wavelet compression to enable long-term recording of electrodermal activity (EDA) within a 64kB microcontroller. The design is implemented on a wearable platform and provides improvements in size and power compared to existing wearable technologies and was used in a lab setting to monitor EDA of 27 participants throughout a stress induction protocol. We demonstrate the device's sensitivity to stress induction by providing descriptive statistics of 8 common EDA signal features for each stressor of the experiment. To the best of our knowledge, this is the first time a generic, 16-bit microcontroller (MCU) has been used to record real-time physiological signals on a wearable platform without the use of external memory chips or wireless transmission for extended periods of time. The compression techniques described can lead to reductions in size, power, and cost of wearable biosensors with little or no modifications to existing sensor hardware and could be valuable for applications interested in monitoring long-term physiological trends at lower data rates and memory requirements.