Eman Frag

Dr. Eman Frag


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

20 October 2010 in The Analyst
Verified
Journal Article
Closed access
PDF file
EFEman Frag
Eman Frag
GMGehad G Mohamed
Gehad G Mohamed
FEF. A. Nour El-Dien
F. A. Nour El-Dien
MMMarwa E. Mohamed
Marwa E. Mohamed
This paper describes the development of screen-printed (SPE) and carbon paste (CPE) sensors for the rapid and sensitive quantification of naphazoline hydrochloride (NPZ) in pharmaceutical formulations. This work compares the electroactivity of conventional carbon paste and screen-printed carbon paste electrodes towards potentiometric titration of NPZ. The repeatability and accuracy of measurements performed in the analysis of these pharmaceutical matrices using new screen printed sensors were evaluated. The influence of the electrode composition, conditioning time of the electrode and pH of the test solution, on the electrode performance were investigated. The drug electrode showed Nernstain responses in the concentration range from 1 × 10−6 to 1 × 10−2 mol L−1 with slopes of 57.5 ± 1.3 and 55.9 ± 1.6 mV per decade for SPE and CPE, respectively, and was found to be very precise and usable within the pH range 3–8. These sensors exhibited a fast response time (about 3 s for both SPE and CPE, respectively), a low detection limit (3.5 × 10−6 and 1.5 × 10−6 M for SPE and CPE, respectively), a long lifetime (3 and 2 months for SPE and CPE, respectively) and good stability. The selectivity of the electrode toward a large number of inorganic cations, sugars and amino acids was tested. It was applied to potentiometric determination of NPZ in pure state and pharmaceutical preparation under batch conditions. The percentage recovery values for the assay of NPZ in tablets (relative standard deviations ≤0.3% for n = 4) were compared well with those obtained by the official method.


31 March 2020 in Journal of Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
EFEman Frag
Eman Frag
MMMarwa E. Mohamed
Marwa E. Mohamed
MEMohamed O. Elhassan
Mohamed O. Elhassan
In this study, electroactivity and performance characteristics of in situ screen printed (ISPEs) and carbon paste (ICPEs) electrodes with different types of ion pairing agents were studied in order to evaluate ramipril (RAM) concentrations in pure solutions, pharmaceutical formulations and biological fluids. The surface analysis of the electrodes was carried out using scanning electron microscopy and energy dispersive X-ray analyzer. The electrodes showed linear responses with good Nernstian slopes of 59.6 ± 0.6 and 58.8 ± 0.8 mV/decade over the concentration range from 5 × 10–7 to 1 × 10–2 M for ISPE and ICPE modified with phosphomolybdic acid (PMA) (electrodes I and III), respectively. At the same time, for ISPE and ICPE modified with phosphotungstic acid (PTA) (electrodes II and IV) slope values of 59.3 ± 0.9 and 58.3 ± 0.9 mV/decade, respectively, were obtained. Also, the two types of electrodes modified with PMA and PTA provided response times of about 5 s for ISPEs and 6 s for ICPEs and exhibited lifetimes of 99 and 92 days for electrodes I and II, respectively, and 68 days for the both paste electrodes (III and IV) in the pH range from 2 to 5 for all the proposed electrodes. They showed high thermal stability where the isothermal coefficients were found to be 0.5 × 10–3 and 1.0 × 10–3 V/grad for electrodes I and II, respectively, and 0.8 × 10–3 and 0.9 × 10–3 V/grad for electrodes III and IV, respectively. Selectivity coefficients of RAM sensors relative to a number of potential interfering materials were investigated. The direct potentiometric determination of ramipril using the prepared sensors gave recoveries between 99.4−99.6, 99.5−99.8, 99.3−99.5 and 99.5−99.6% using electrodes I, II, III and IV, respectively. The developed method was found to be simple, precise and accurate when compared to the reported methods. Method validation parameters were optimized according to IUPAC recommendations.

1 September 2018 in Journal of the Iranian Chemical Society
Verified
Journal Article
Closed access
PDF file
NENahed A. Abd El-Ghany
Nahed A. Abd El-Ghany
EFEman Frag
Eman Frag
MFMohammed Abd El Fattah
Mohammed Abd El Fattah

4 May 2019 in Analytical Chemistry Letters
Verified
Journal Article
Closed access
GMGehad G. Mohamed
Gehad G. Mohamed
EFEman Frag
Eman Frag
MMMarwa El Mohamed
Marwa El Mohamed
MEMohamed O. Elhassan
Mohamed O. Elhassan
Ramipril was a prodrug and it was an angiotensin converting enzyme (ACE) inhibitor which can be used to treat congestive heart failure and hypertension. In this study, the electro activity and the performance characteristics of modified screen-printed (MSPEs) and carbon paste (MCPEs) electrodes with different types of ion pairs had been studied in order to determine ramipril (RAM) drug in pure solution, pharmaceutical formulations and biological fluid samples. The ion pair formation between RAM and phosphomolybdic acid (PMA) or phosphotungstic acid (PTA) or sodium teteraphenyl borate (Na-TPB) was the basis of preparation of modified ion selective electrodes used in this study. The surface analysis of the electrodes was studied using scanning electron microscope (SEM) and X-ray diffraction (XRD). The electrodes showed linear response with good Nernstian slope of 58.50±1.08, 59.00±0.96, 59.60±0.73 mV decade-1 for MSPEs modified with RAM-TPB, RAM-PMA and RAM-PTA ion pairs, respectively, and 59.20±0.96, 58.90±1.01 mV decade-1 for MCPEs modified with RAM-TPB and RAM-PTA ion pairs, respectively, over the concentration range from 5.0 x 10-7 to 1.0 x 10-2 mol L-1. Although, the two types of electrodes provided response time of about 4 s for MSPEs and 5 s for MCPEs and exhibited lifetimes of 99 to 92 days for MSPE electrodes and 67 days for both electrodes of MCPEs on pH range from 2 to 5 for MSPEs and 2 to 4 for MCPEs. They showed high thermal stability according to the isothermal coefficients values. Selectivity coefficients of RAM sensors relative to a number of potential interfering materials were investigated. The developed method was found to be simple, precise and accurate when compared with the reported method.