Mohd Yaacob

Dr. Mohd Yaacob


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2009 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
MYMohd Yaacob
Mohd Yaacob
MBMichael Breedon
Michael Breedon
KKK. Kalantar-Zadeh
K. Kalantar-Zadeh
WWW. Wlodarski
W. Wlodarski

1 November 2017 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
MRMohammad Bagher Rahmani
Mohammad Bagher Rahmani
MYMohd Yaacob
Mohd Yaacob
Ylias SabriYlias Sabri
Ylias Sabri

9 March 2011 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
Jian Zhen OuJian Zhen Ou
Jian Zhen Ou
MYMohd Yaacob
Mohd Yaacob
MBMichael Breedon
Michael Breedon
HZH. D. Zheng
H. D. Zheng
JCJ. L. Campbell
J. L. Campbell
KKK. Kalantar-Zadeh
K. Kalantar-Zadeh
It is well known that WO3 interacts efficiently with H2 gas in the presence of noble metals (such as Pd, Pt and Au) at elevated temperatures, changing its optical behaviors; and that its crystallinity plays an important role in these interactions. For the first time, we investigated the in situRaman spectra changes of WO3 films of different crystal phases, while incorporating Pd catalysts, at elevated temperatures in the presence of H2. The Pd/WO3 films were prepared using RF sputtering and subsequently annealed at 300, 400 and 500 °C in air in order to alter the dominant crystal phase. The films were then characterized using SEM, XRD, XPS, and both UV-VIS and Raman spectroscopy. In order to fundamentally study the process, the measurements were conducted when films were interacting with 1% H2 in synthetic air at elevated sample temperatures (20, 60, 100 and 140 °C). We suggest that the changes of Raman spectra under such conditions to be mainly a function of the crystal phase, transforming from monoclinic to a mix phase of monoclinic and orthorhombic achieved via increasing the annealing temperature. The as-deposited sample consistently shows similar Raman spectra responses at different operating conditions upon H2 exposure. However, increasing the annealing temperature to 500 °C tunes the optimum H2 response operating temperature to 60 °C.

1 May 2014 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
NLNurul Fariha Lokman
Nurul Fariha Lokman
ABAhmad Ashrif A Bakar
Ahmad Ashrif A Bakar
FSFatihah Suja
Fatihah Suja
HAHuda Abdullah
Huda Abdullah
WRWan Baihaqi Wan Ab Rahman
Wan Baihaqi Wan Ab Rahman
MYMohd Yaacob
Mohd Yaacob

1 June 2017 in Electrochimica Acta
Verified
Journal Article
Closed access
SLS.C. Lau
S.C. Lau
HLHong Ngee Lim
Hong Ngee Lim
TRT.B.S.A. Ravoof
T.B.S.A. Ravoof
MYMohd Yaacob
Mohd Yaacob
David GrantDavid Grant
David Grant
NHN.M. Huang
N.M. Huang

1 January 2015 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
AAAziz A.
Aziz A.
HLHong Ngee Lim
Hong Ngee Lim
SGSaad Hayatu Girei
Saad Hayatu Girei
MYMohd Yaacob
Mohd Yaacob
MMMahdi M.A.
Mahdi M.A.
PAPandikumar A.
Pandikumar A.