Isotopes of some metals are used in medical applications like diagnosis/treatment of cancer, arthritis and other illnesses and in nuclear reactors for neutron shielding. Although Atomic Vapor Laser Isotope Separation (AVLIS) route for separation of these isotopes is preferred, production of desired isotope at high quantity and quality (enrichment) is a challenge. Generally, in AVLIS process, for efficient collection of ions produced by laser, collector plate is kept at high voltage of about -3 kV. So, the collected ions hit the plates at kinetic energy of ~3 keV and in turn sputter out the previously deposited atoms (sputtering yield is ~2 to 3). So, maximum quantity of product that can be produced by the process is only a few layers of atoms on the plate. In addition, since the ion collector plate is kept close to the plasma for generating sufficient electric field for extraction of ions, the plate collects some undesired isotopes scattered from the vapor stream diluting the enrichment of the product. To avoid these problems of sputtering by collected ions (limiting quantity of product) and scattering of undesired atoms onto the plate (limiting quality), we design a new ion collection geometry using a combination of grid and plate structure. We derive analytical expressions to theoretically evaluate the performance of our ion collection geometry and compare it with performance of conventional geometry. Both quantity and quality of product in our design are found to be significantly better than that of conventional method.
1 January 2022 in Review of Scientific Instruments
Electrode geometry plays a vital role in metal vapor laser performance. It has been observed that by modifying the electrode geometry, the electric field enhancement near the electrode can be reduced. Reduction in the localized electric field causes reduction in the phantom current in the metal vapor laser. On replacing the electrode geometry having eight pins with an electrode having the zero-pin configuration, a 10% decrease in the phantom current and a 23% increase in optical output power are observed. The low phantom current is responsible for higher efficiencies, large specific average output power, and improved beam characteristics of that laser in reference to a conventional copper vapor laser. It was also observed that reduction in field enhancement causes reduction in the thermal loading at the cathode fall and in the probability of thermal instability, thereby improving the discharge stability and jitter in metal vapor lasers. This simple and effective technique can also be applied to the systems requiring high current and high-volume stable discharge.
One of the most important problems in astronomy is the cosmological constant problem in which conventional calculation of vacuum energy density using quantum mechanics leads to a value which is ~10 123 times more than the vacuum energy estimated from astronomical observations of expanding universe. The cosmic coincidence problem questions why matter energy density is of the same order of magnitude as the vacuum energy density at present time. Finally, the mechanism responsible for spatial flatness is not clearly understood. In this paper, by taking the vacuum as a finite and closed quantum oscillator, we solve all of the above-mentioned problems. At first, by using the purely quantum mechanical approach, we predict that the dark energy density is c4 /( GR2 ) = 5.27×10 −10 J/m 3 (where R is radius of 3-sphere of the universe) and matter energy density is c4 /(2 GR2 ) = 2.6×10 −10 J/m 3 which match well with astronomical observations. We also prove that dark energy has always been ~66.7% and matter energy has been ~33.3% of the total energy and thus solve the cosmic coincidence problem. Next, we show how flatness of space could be maintained since the early stage of the universe. Finally, using our model, we derive the expression for age and radius of the universe which match well with the astronomical data.
15 June 2016 in Measurement Science and Technology
The atomic vapor generated by electron beam heating is partially ionized due to atom–atom collisions (Saha ionization) and electron impact ionization, which depend upon the source temperature and area of evaporation as compared to the area of electron beam bombardment on the target. When electron beam evaporation is carried out by inserting the target inside an insulating liner to reduce conductive heat loss, it is expected that the area of evaporation becomes significantly more than the area of electron beam bombardment on the target, resulting in reduced electron impact ionization. To assess this effect and to quantify the parameters of evaporation, such as temperature and area of evaporation, we have carried out experiments using zirconium, tin and aluminum as a target. By measuring the ion content using a Langmuir probe, in addition to measuring the atomic vapor flux at a specific height, and by combining the experimental data with theoretical expressions, we have established a method for simultaneously inferring the source temperature, evaporation area and ion fraction. This assumes significance because the temperature cannot be reliably measured by an optical pyrometer due to the wavelength dependent source emissivity and reflectivity of thin film mirrors. In addition, it also cannot be inferred from only the atomic flux data at a certain height as the area of evaporation is unknown (it can be much more than the area of electron bombardment, especially when the target is placed in a liner). Finally, the reason for the lower observed electron temperatures of the plasma for all the three cases is found to be the energy loss due to electron impact excitation of the atomic vapor during its expansion from the source.
In this paper, we design and demonstrate a compact laser-based sensor for measurement of the position of a target placed at a long standoff distance. To make the sensor compact, beam-folding technique was used in the path of the converging light from the lens, which ultimately falls on the position-sensing detector (PSD). Position resolution of 1 mm at a standoff distance of ~1000 mm between the target and light collecting lens was achieved for the developed sensor. The calibration of the sensor was done based on the output voltage obtained at PSD with near and far displaced position of the target. The sensor output was found to be linearly varying with the target position. The sensor performance was tested for different target roughness and ± 10° variation in angle between laser and target surface. The effect of temperature on the output of developed sensor was also studied and the error in measurement was found to be within the sensor resolution. The developed sensor has many potential applications in industrial environments where the position has to be measured for targets having different surface roughness and variable ambient temperature.
1 September 2008 in Review of Scientific Instruments
State resolved atom population of metal vapor having low-lying metastable states departs from equilibrium value. It needs to be experimentally investigated. This paper reports the use of hollow cathode lamp based atomic absorption spectroscopy technique to measure online the state resolved atom density (ground and metastable) of metal vapor in an atomic beam produced by a high power electron gun. In particular, the advantage of availability of multiwavelength emission in hollow cathode lamp is used to determine the atom density in different states. Here, several transitions pertaining to a given state have also been invoked to obtain the mean value of atom density thereby providing an opportunity for in situ averaging. It is observed that at higher source temperatures the atoms from metastable state relax to the ground state. This is ascribed to competing processes of atom-atom and electron-atom collisions. The formation of collision induced virtual source is inferred from measurement of atom density distribution profile along the width of the atomic beam. The total line-of-sight average atom density measured by absorption technique using hollow cathode lamp is compared to that measured by atomic vapor deposition method. The presence of collisions is further supported by determination of beaming exponent by numerically fitting the data.