High time resolution in scattering analysis of thin films allows for determination of thermal conductivity by transient pump-probe detection of dissipation of laser-induced heating, TDXTS. We describe an approach that analyses the picosecond-resolved lattice parameter reaction of a gold transducer layer on pulsed laser heating to determine the thermal conductivity of layered structures below the transducer. A detailed modeling of the cooling kinetics by a Laplace-domain approach allows for discerning effects of conductivity and thermal interface resistance as well as basic depth information. The thermal expansion of the clamped gold film can be calibrated to absolute temperature change and effects of plastic deformation are discriminated. The method is demonstrated on two extreme examples of phononic barriers, isotopically modulated silicon multilayers with very small acoustic impedance mismatch and silicon-molybdenum multilayers, which show a high resistivity.
23 July 2005 in Acta Crystallographica Section E Structure Reports Online
MgCO3·MgCl2·7H2O is the only known neutral magnesium carbonate containing chloride ions at ambient conditions. According to the literature, only small and twinned crystals of this double salt could be synthesised in a concentrated solution of MgCl2. For the crystal structure solution, single-crystal diffraction was carried out at a synchrotron radiation source. The monoclinic crystal structure (space group Cc) exhibits double chains of MgO octahedra linked by corners, connected by carbonate units and water molecules. The chloride ions are positioned between these double chains parallel to the (100) plane. Dry MgCO3·MgCl2·7H2O decomposes in the air to chlorartinite, Mg2(OH)Cl(CO3)·nH2O (n = 2 or 3). This work includes an extensive characterization of the title compound by powder X-ray diffraction, thermal analysis, SEM and vibrational spectroscopy.
22 March 2013 in Journal of Physics: Conference Series
Different methods have been proposed to calculate the vertical position of the photon beam centroid from the four blade currents of staggered pair X-ray beam position monitors (XBPMs) at bending magnet beamlines since they emerged about 15 years ago. The original difference-over-sum method introduced by Peatman and Holldack is still widely used, even though it has been proven to be rather inaccurate at large beam displacements. By systematically generating bumps in the electron orbit of the ANKA storage ring and comparing synchronized data from electron BPMs and XBPM blade currents, we have been able to show that the log-ratio method by S. F. Lin, B.G. Sun et al. is superior (meaning the characteristic being closer to linear) to the ratio method, which in turn is superior to the difference over sum method. These findings are supported by simulations of the XBPM response to changes of the beam centroid. The heuristic basis for each of the methods is investigated. The implications on using XBPM readings for orbit correction are discussed