In order to improve the performance of X-band dual-polarization radars, it is necessary to conduct attenuation correction before using the X-band radar data. This study analyzes a variety of attenuation correction methods for the X-band radar reflectivity, and proposes a high-resolution slide self-consistency correction (SSCC) method, which is an improvement of Kim et al.’s method based on Bringi et al.’s original method. The new method is comprehensively evaluated with the observational data of convective cloud, stratiform cloud, and the stratiform cloud with embedded convection. Comparing with the intrinsic reflectivity at X-band calculated from the reflectivity at S-band, it is found that the new method can effectively reduce the correction errors when calculating differential propagation shift increments using the conventional self-consistency attenuation correction method. This method can efficiently correct the X-band dual-polarization radar reflectivity, in particular, for the echoes with reflectivity greater than 35 dBZ.
10 April 2020 in IEEE Transactions on Geoscience and Remote Sensing
An inverse mapping table (IMT) method is proposed in this article to retrieve the raindrop size distribution (RSD) parameters from X-band polarimetric weather radar data. In the IMT method, a forward mapping database from three parameters of a gamma-type RSD to polarimetric radar variables is first built based on the scattering simulations under ideal atmospheric conditions, and then an inverse mapping database is derived. In particular, given a fixed shape parameter (μ) of RSD, the intersection of horizontal reflectivity (ZH) and differential reflectivity (ZDR) contour lines is first obtained in the domain of total number concentration (NT) and median volume diameter (MVD) D₀; and the inverse mapping relationship between ZH and ZDR to NT and D₀ at a fixed μ value is derived to form a single layer of IMT. Then, the monotonic relationship between μ and the specific differential propagation phase shift (KDP) or backscatter differential phase (δCO) can aid in determining μ and a single layer of IMT. Thus, the inverse mapping database from polarimetric observations to the three gamma-type RSD parameters μ, NT, and D₀ can be established. Demonstration studies during a convective rainfall event and a large-scale rainfall event which occurred in northeastern China are carried out to examine the performance of this IMT method compared to a constrained-gamma (C-G) method that uses empirical relations between RSD parameters. The results show that the IMT method has a better performance in the convective case and similar performance in the large-scale continuous rainfall case.
A convective cell storm containing two differential reflectivity (ZDR) columns was observed with a dual-polarization phased-array radar (X-PAR) in Xixian County. Since a ZDR column is believed to correspond to a strong updraft and a single convective cell is considered to have a simple dynamic structure with one updraft core, how these two ZDR columns form and coexist is the focus of this study. The dynamic and microphysical structures around the two ZDR columns are studied under the mutual confirmation of the X-PAR observations and a cloud model simulation. The main ZDR column forms and maintains in an updraft whose bottom corresponds to a convergence of low-level and mid-level flow; it lasts from the early stages to the later stages. The secondary ZDR column emerges at the rear of the horizontal reflectivity (ZH) core relative to the moving direction of the cell; it forms in the middle stages and lasts for a shorter period, and its formation is under an air lifting forced by the divergent outflow of precipitation. Therefore, the secondary ZDR column is only a by-product in the middle stages of the convection rather than an indicator of a new or enhanced convection.
A uniformity index for the axis ratios (Uar) derived from dual polarization weather radar data is proposed for raindrop area identification and analysis. The derivation of this new parameter is based on radar scattering simulations and assumptions. Uar is between 0 and 1 and can be calculated from the differential reflectivity (ZDR) and the copolar correlation coefficient (ρhv), which reflects the uniformity of the axis ratio (r) of the particle group. For raindrops, Uar is close to 1 under ideal conditions, but is clearly different from that of ice particles whose value is close to 0. Studies conducted during two convective weather events observed by X-band and S-band radar are presented to show the Uar features. In convective areas, high Uar presents a U-shaped vertical structure. One branch corresponds to the ZDR column, while the other branch is located at the rear of the convective cloud zone and is lower in altitude, representing the process of ice particles melting into raindrops and then being transported upward by a strong updraft. In stratiform cloud areas, a more than 95% overall identification ratio is obtained when the threshold of Uar is set to 0.2~0.3 for discriminating rain layers.
A nonlinear grid transformation (NGT) method is proposed for weather radar convective echo extrapolation prediction. The change in continuous echo images is regarded as a nonlinear transformation process of the grid. This process can be reproduced by defining and solving a 2 × 6 transformation matrix, and this approach can be applied to image prediction. In ideal experiments with numerical and path changes of the target, NGT produces a prediction result closer to the target than does a conventional optical flow (OF) method. In the presence of convection lines in real cases, NGT is superior to OF: the critical success index (CSI) for 40 dBZ of the echo prediction at 60 min is approximately 0.2 higher. This is due to the better estimation of the movement of the whole cloud system in the NGT results since it reflects the continuous change in the historical images. For the case with a mesoscale convective complex, the NGT results are better than the OF results, and a deep learning result is cited from a previous study for the same case for 20 and 30 dBZ. However, the result is the opposite for 40 dBZ, where the deep learning method may produce an overestimation of the stronger echo.
25 July 2026 in Journal of Geophysical Research: Atmospheres
We developed an innovative balloon‐borne observation system based on China's BeiDou sounding platform that integrates a three‐axis electric field sensor for in‐cloud measurements of thunderstorm electrification. On 13 May 2025, this system was deployed during a severe convective storm over Beijing. In combination with multisource observations, including S‐band dual‐polarization radar, lightning location networks, and surface electric field meters, we analyzed the charge structure, microphysics, and lightning activity. Multiple electric field peaks, including one with a sustained maximum of 333 kV m −1 at altitudes from 7 to 8 km, were sampled via balloon sounding. The retrieved vertical charge structure comprised a thin negative–positive–negative stack at altitudes from 4 to 5 km (≈0.25–0.30‐km thick) and a main three‐layer system above 4.9 km, comprising a lower positive region (+2.5 nC m −3 , 4.9–6.2 km, −10°C to −20°C), a middle negative region (−7.2 nC m −3 , 6.2–6.9 km, −20°C to −25°C), and an upper positive region (+1.1 nC m −3 , 6.9–9.6 km, near −40°C). Although the sensor was designed to measure three‐dimensional electric fields, the horizontal electric field components ( Ex and Ey ) were found to be dominated by cross‐talk from Ez during this flight and therefore cannot be interpreted as independent horizontal electric fields. Consequently, the physical interpretation in this study is based solely on the vertical electric field and the charge structure inferred from it. Lightning was dominated by short, multipulse IC flashes in the convective cores. The balloon traversed the main updraft and mixed‐phase zone (0°C to −40°C), thus confirming that the profiles captured key features of storm core electrification.