Audrey Bouchet

Dr. Audrey Bouchet

UA8 INSERM Unit "Radiation: Defense, Health Environment", Bât Cheney A 1er étage - 28 Rue Laennec, 69008 Lyon, France
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
PMPierre Montay-Gruel
Pierre Montay-Gruel
ABAudrey Bouchet
Audrey Bouchet
MJMaud Jaccard
Maud Jaccard
DPDavid Patin
David Patin
RSRaphael Serduc
Raphael Serduc
MVMarie-Catherine Vozenin
Marie-Catherine Vozenin

31 October 2011 in ACS Nano
Verified
Journal Article
Closed access
GDGéraldine Le Duc
Géraldine Le Duc
IMImen Miladi
Imen Miladi
CAChristophe Alric
Christophe Alric
PMPierre Mowat
Pierre Mowat
EBElke Bräuer-Krisch
Elke Bräuer-Krisch
OTOlivier Tillement
Olivier Tillement

1 December 2010 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
ABAudrey Bouchet
Audrey Bouchet
BLBenjamin Lemasson
Benjamin Lemasson
GDGéraldine Le Duc
Géraldine Le Duc
CMCécile Maisin
Cécile Maisin
EBElke Bräuer-Krisch
Elke Bräuer-Krisch
RSRaphael Serduc
Raphael Serduc

1 September 2015 in Physica Medica
Verified
Journal Article
Open access
ABAudrey Bouchet
Audrey Bouchet
RSRaphael Serduc
Raphael Serduc
JLJean Albert Laissue
Jean Albert Laissue
Valentin DjonovValentin Djonov
Valentin Djonov
Microbeam radiation therapy (MRT) is a new form of preclinical radiotherapy using quasi-parallel arrays of synchrotron X-ray microbeams. While the deposition of several hundred Grays in the microbeam paths, the normal brain tissues presents a high tolerance which is accompanied by the permanence of apparently normal vessels. Conversely, the efficiency of MRT on tumor growth control is thought to be related to a preferential damaging of tumor blood vessels. The high resistance of the healthy vascular network was demonstrated in different animal models by in vivo biphoton microscopy, magnetic resonance imaging, and histological studies. While a transient increase in permeability was shown, the structure of the vessels remained intact. The use of a chick chorioallantoic membrane at different stages of development showed that the damages induced by microbeams depend on vessel maturation. In vivo and ultrastructural observations showed negligible effects of microbeams on the mature vasculature at late stages of development; nevertheless a complete destruction of the immature capillary plexus was found in the microbeam paths. The use of MRT in rodent models revealed a preferential effect on tumor vessels. Although no major modification was observed in the vasculature of normal brain tissue, tumors showed a denudation of capillaries accompanied by transient increased permeability followed by reduced tumor perfusion and finally, a decrease in number of tumor vessels. Thus, MRT is a very promising treatment strategy with pronounced tumor control effects most likely based on the anti-vascular effects of MRT.

20 October 2009 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
RSRaphael Serduc
Raphael Serduc
ABAudrey Bouchet
Audrey Bouchet
EBElke Bräuer-Krisch
Elke Bräuer-Krisch
JLJean A Laissue
Jean A Laissue
JSJenny Spiga
Jenny Spiga
GDGéraldine Le Duc
Géraldine Le Duc
To analyze the effects of the microbeam width (25, 50 and 75 mu m) on the survival of 9L gliosarcoma tumor-bearing rats and on toxicity in normal tissues in normal rats after microbeam radiation therapy (MRT), 9L gliosarcomas implanted in rat brains, as well as in normal rat brains, were irradiated in the MRT mode. Three configurations (MRT25, MRT50, MRT75), each using two orthogonally intersecting arrays of either 25, 50 or 75 mu m wide microbeams, all spaced 211 mu m on center, were tested. For each configuration, peak entrance doses of 860, 480 and 320 Gy, respectively, were calculated to produce an identical valley dose of 18 Gy per individual array at the center of the tumor. Two, 7 and 14 days after radiation treatment, 42 rats were killed to evaluate histopathologically the extent of tumor necrosis, and the presence of proliferating tumors cells and tumor vessels. The median survival times of the normal rats were 4.5, 68 and 48 days for MRT25, 50 and 75, respectively. The combination of the highest entrance doses (860 Gy per array) with 25 mu m wide beams (MRT25) resulted in a cumulative valley dose of 36 Gy and was excessively toxic, as it led to early death of all normal rats and of similar to 50% of tumor-bearing rats. The short survival times, particularly of rats in the MRT25 group, restricted adequate observance of the therapeutic effect of the method on tumor-bearing rats. However, microbeams of 50 mu m width led to the best median survival time after 9L gliosarcoma MRT treatment and appeared as the better compromise between tumor control and normal brain toxicity compared with 75 mu m or 25 mu m widths when used with a 211 mu m on-center distance. Despite very high radiation doses, the tumors were not sterilized; viable proliferating tumor cells remained present at the tumor margin. This study shows that microbeam width and peak entrance doses strongly influence tumor responses and normal brain toxicity, even if valley doses are kept constant in all groups. The use of 50 mu m wide microbeams combined with moderate peak doses resulted in a higher therapeutic ratio.

1 July 2013 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
ABAudrey Bouchet
Audrey Bouchet
BLBenjamin Lemasson
Benjamin Lemasson
TCThomas Christen
Thomas Christen
MPMarine Potez
Marine Potez
CRClaire ROME
Claire ROME
RSRaphael Serduc
Raphael Serduc