The study goal was to determine if on-site wastewater systems (OSWWS) installed in coastal areas were effective at reducing indicator bacteria densities before discharge to groundwater. Groundwater Escherichia coli (E. coli) densities and groundwater levels adjacent to 16 OSWWS in three different soil groups (sand, sandy loam, and sandy clay loam) were monitored and compared to background groundwater conditions on four occasions between March 2007 and February 2008 in coastal North Carolina. Groundwater beneath OSWWS had significantly (p≤0.05) lower densities of E. coli than septic tank effluent, but significantly higher densities of E. coli than background conditions for each soil type. Twenty three percent of all groundwater samples near OSWWS had E. coli densities that exceeded the EPA freshwater contact standards (single sample 235 cfu/100 mL) for surface waters. Groundwater E. coli densities near OSWWS were highest during shallow water table periods. The results indicate that increasing the required vertical separation distance from drainfield trenches to seasonal high water table could improve shallow groundwater quality.
On-site wastewater treatment systems (OWS) are a potentially significant non-point source of nutrients to groundwater and surface waters, and are extensively used in coastal North Carolina. The goal of this study was to determine the treatment efficiency of four OWS in reducing total dissolved nitrogen (TDN) and dissolved organic carbon (DOC) concentrations before discharge to groundwater and/or adjacent surface water. Piezometers were installed for groundwater sample collection and nutrient analysis at four separate residences that use OWS. Septic tank effluent, groundwater, and surface water samples (from an adjacent stream) were collected four times during 2012 for TDN and DOC analysis and pH, temperature, electrical conductivity, and dissolved oxygen measurements. Treatment efficiencies from the tank to the groundwater beneath the drainfields ranged from 33 to 95% for TDN and 45 to 82% for DOC, although dilution accounted for most of the concentration reductions. There was a significant positive correlation between nitrate concentration and separation distance from trench bottom to water table and a significant negative correlation between DOC concentration and separation distance. The TDN and DOC transport (>15 m) from two OWS with groundwater saturated drainfield trenches was significant.
The goal of this study was to determine if onsite wastewater treatment systems (OWS) were influencing groundwater and surface water Escherichia coli concentrations in a coastal plain watershed. Piezometers for groundwater monitoring were installed at four residences served by OWS and five residences served by a municipal wastewater treatment system (MWS). The residences were located in two different, but nearby (<3 km), watersheds. Effluent from the four septic tanks, groundwater from piezometers, and the streams draining the OWS and MWS watersheds were sampled on five dates between September 2011 and May 2012. Groundwater E. coli concentrations and specific conductivity were elevated within the flow path of the OWS and near the stream, relative to other groundwater sampling locations in the two watersheds. Groundwater discharge in the OWS watershed could be a contributor of E. coli to the stream because E. coli concentrations in groundwater at the stream bank and in the stream were similar. Stream E. coli concentrations were higher for the OWS in relation to MWS watersheds on each sampling date. Water quality could be improved by ensuring OWS are installed and operated to maintain adequate separation distances to water resources.