Han Wang

Prof. Han Wang

Tsinghua University, Beijing, China
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MYMuqun Yang
Muqun Yang
HWHan Wang
Han Wang
PLPeng Liu
Peng Liu
JCJing Cheng
Jing Cheng

31 January 2024 in Cell Reports Physical Science
Verified
Journal Article
Open access
XWXueqi Wang
Xueqi Wang
JZJianhua Zhou
Jianhua Zhou
HWHan Wang
Han Wang

31 March 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
MLMingyang Liu
Mingyang Liu
MYMuqun Yang
Muqun Yang
MWMuxue Wang
Muxue Wang
HWHan Wang
Han Wang
JCJing Cheng
Jing Cheng
Electrochemical biosensors have been widely applied in the development of metabolite detection systems for disease management. However, conventional intravenous and fingertip blood tests are invasive and cannot track dynamic trends of multiple metabolites. Among various body fluids, saliva can be easily accessed and is regarded as a promising candidate for non-invasive metabolite detection. Recent works on the development of electrochemical biosensors for monitoring salivary metabolites have demonstrated high sensitivity and wide linear range. However, most of this research has been focused on salivary detection of a single metabolite. Here, we present a dual-channel electrochemical biosensor for simultaneous detection of lactate and glucose in saliva based on a flexible screen-printed electrode with two working electrodes. The sensitivities of glucose and lactate channels were 18.7 μA/(mM·cm2) and 21.8 μA/(mM·cm2), respectively. The dual-channel biosensor exhibited wide linear ranges of 0–1500 μM for the glucose channel and 0–2000 μM for the lactate channel and the cross-talk between the two detection channels was negligible, which made it adequately suitable for sensing low-level salivary metabolites. Such attractive characteristics demonstrate the potential of this dual-analyte biosensor in the development of wearable devices for monitoring disease progression and fitness.

16 December 2024 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
XWXueqi Wang
Xueqi Wang
JCJing Cheng
Jing Cheng
HWHan Wang
Han Wang
Chronic wounds, which require prolonged healing periods, pose significant impacts on individuals with diabetes, vascular diseases, and high blood pressure. Simultaneous drainage and monitoring of wound exudate are vital for advanced wound management. However, recently reported smart dressings either lack integration of wound cleaning and monitoring functions or fail to achieve dynamic in situ monitoring of wound status, which hinders their ability to meet the demands of wound care. In this study, a smart bandage is introduced, which integrates a biocompatible liquid diode membrane with an ultrasensitive 3D polyaniline mesh (M-PANI)-based pH biosensor. The smart bandage allows for unidirectional drainage of wound exudate while dynamically sensing the wound pH environment. Specifically, the proposed smart bandage effectively cleans excessive wound exudate while providing real-time information on the wound status during the drainage process. The M-PANI-based pH biosensor demonstrates a high sensitivity of 61.5 mV/pH and a wide pH detection range from 4.0 to 10.0, encompassing the pH range of normal and infected wounds. Moreover, the sensing module exhibits excellent stability after 48 hours of dynamic testing and 28 days of storage, with only a 4.8% decline in the detected signal, and high repeatability with a device-to-device relative standard deviation (RSD) of 3.1%. To evaluate the practicality of this smart bandage, simulated skin and rats have been employed, and the results indicate the immense potential of this smart bandage for clinical applications. In conclusion, the present smart bandage demonstrates considerable promise for wound exudate cleaning and monitoring in advanced wound care and offers a promising method for home-based wound management.

10 January 2019 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
HWHan Wang
Han Wang
ZLZhongzheng Liu
Zhongzheng Liu
DSDong M. Shin
Dong M. Shin
ZCZhuo G. Chen
Zhuo G. Chen
Young Hak ChoYoung Hak Cho
Young Hak Cho
Arum HanArum Han
Arum Han
A continuous-flow single-cell mechanotyping method which can decouple the cell size-dependent effect from the cell compressibility-dependent effect is presented.

13 September 2022 in ACS Nano
Verified
Journal Article
Closed access
HWHan Wang
Han Wang
XWXueqi Wang
Xueqi Wang
JCJing Cheng
Jing Cheng