DANIELA MAFFIODO

DANIELA MAFFIODO

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2009 in The International Journal of Robotics Research
Verified
Journal Article
Closed access
giuseppe quagliagiuseppe quaglia
giuseppe quaglia
DMDANIELA MAFFIODO
DANIELA MAFFIODO
WFW. Franco
W. Franco
SAS. Appendino
S. Appendino
ROR. Oderio
R. Oderio
In this paper we propose an innovative solution for a small size hybrid mobile robot called Epi.q-1. Overall dimensions are about 160 mm x 360 mm x 280 mm (height x length x width). The Epi.q-1 robot moves on flat, steep or uneven ground. It can climb over obstacles or steps, even if they are non-uniform in size. Its operating mode adapts to ground conditions and changes accordingly: from rolling (on wheels) to stepping (on legs); thanks to its great mobility it can follow complex routes. It is easy to control with just a few actuators. Robot locomotion drive-generating units employ an original driving mechanism, where degrees of freedom (DOFs) can be limited to some extent according to the operating conditions or thanks to a switching device. Locomotion units consist of a motor linked to a gear (double epicyclical chain) and an axial device (mini-motor and lead screw system) able to lock or unlock some DOFs of the kinematic chain. Moreover, the robot locomotion unit can change its size, from small to large and vice versa, in order to be able to reach restricted spaces and to overcome even quite tall obstacles. It was experimentally tested on flat ground and slopes. It can overcome 90 mm obstacles, that are 72% of the height of the locomotion unit, and climb stairs.

1 December 2017 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
AMAlessandro Messere
Alessandro Messere
GCGianluca Ceravolo
Gianluca Ceravolo
WFWalter Franco
Walter Franco
DMDANIELA MAFFIODO
DANIELA MAFFIODO
CFCarlo Ferraresi
Carlo Ferraresi
Silvestro RoattaSilvestro Roatta
Silvestro Roatta
The rapid hyperemia evoked by muscle compression is short lived and was recently shown to undergo a rapid decrease even in spite of continuing mechanical stimulation. The present study aims at investigating the mechanisms underlying this attenuation, which include local metabolic mechanisms, desensitization of mechanosensitive pathways, and reduced efficacy of the muscle pump. In 10 healthy subjects, short sequences of mechanical compressions (n = 3–6; 150 mmHg) of the lower leg were delivered at different interstimulus intervals (ranging from 20 to 160 s) through a customized pneumatic device. Hemodynamic monitoring included near-infrared spectroscopy, detecting tissue oxygenation and blood volume in calf muscles, and simultaneous echo-Doppler measurement of arterial (superficial femoral artery) and venous (femoral vein) blood flow. The results indicate that 1) a long-lasting (>100 s) increase in local tissue oxygenation follows compression-induced hyperemia, 2) compression-induced hyperemia exhibits different patterns of attenuation depending on the interstimulus interval, 3) the amplitude of the hyperemia is not correlated with the amount of blood volume displaced by the compression, and 4) the extent of attenuation negatively correlates with tissue oxygenation (r = −0,78, P < 0.05). Increased tissue oxygenation appears to be the key factor for the attenuation of hyperemia upon repetitive compressive stimulation. Tissue oxygenation monitoring is suggested as a useful integration in medical treatments aimed at improving local circulation by repetitive tissue compression. NEW & NOTEWORTHY This study shows that 1) the hyperemia induced by muscle compression produces a long-lasting increase in tissue oxygenation, 2) the hyperemia produced by subsequent muscle compressions exhibits different patterns of attenuation at different interstimulus intervals, and 3) the extent of attenuation of the compression-induced hyperemia is proportional to the level of oxygenation achieved in the tissue. The results support the concept that tissue oxygenation is a key variable in blood flow regulation.

18 December 2013 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
Carlo FERRARESICarlo FERRARESI
Carlo FERRARESI
DMDANIELA MAFFIODO
DANIELA MAFFIODO
HHHamidreza Hajimirzaalian
Hamidreza Hajimirzaalian
Intermittent pneumatic compression is a well-known technique, which can be used for several therapeutic treatments like sports recovery, lymphoedema drainage, deep vein thrombosis prevention or others, which may require very different operating characteristics as regards the desired pressure values and the operating velocity. The performance and the effectiveness of the device are often difficult to predict and must be usually optimized through empirical adjustments. This article presents a general method based on the mathematical modelling of a generic IPC system, aimed at studying and developing such a device with physical and dynamical characteristics suitable for the intended application.

1 March 1999 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
Carlo FERRARESICarlo FERRARESI
Carlo FERRARESI
ABA. Manuello Bertetto
A. Manuello Bertetto
LML. Mazza
L. Mazza
DMDANIELA MAFFIODO
DANIELA MAFFIODO
WFW. Franco
W. Franco

28 April 2017 in International Journal of Automation Technology
Verified
Journal Article
Closed access
DMDANIELA MAFFIODO
DANIELA MAFFIODO
TRTerenziano Raparelli
Terenziano Raparelli
A three-fingered gripper with flexure hinges actuated by shape memory alloy (SMA) wires was designed and prototyped. The aim of the work was the manipulation of small, almost cylindrical objects, e.g. test tubes, by a device having small overall dimensions. A parametric study of four different, but similar, fingers was conducted with the aim of obtaining a solution with a good amplification ratio and a gripping force almost constant during closure. The use of flexure hinges simplifies the design, but limits the finger range of motion. Moreover, it was possible to find a configuration with sufficient work space. Once the finger geometry was defined, the whole hand was then designed with the aim of producing a compact hand contained in a cylindrical volume (φ 65×h 65 mm), and the first prototype was built. Preliminary tests demonstrated its good dimensioning and the success of some technological solutions. The experimental transmission ratio was almost the same as the theoretical one. Some drawbacks have been highlighted, such as a reduced range of motion and incomplete backstroke; future studies will deal with them.

10 June 2019 in Machines
Verified
Journal Article
Open access
PDF file
DMDANIELA MAFFIODO
DANIELA MAFFIODO
Terenziano RaparelliTerenziano Raparelli
Terenziano Raparelli
To meet the needs of present-day robotics, a family of gripping flexible fingers has been designed. Each of them consists of a number of independent and flexible modules that can be assembled in different configurations. Each module consists of a body with a flexible central rod and three longitudinally positioned shape memory alloy (SMA) wires. When heated by the Joule effect, one to two SMA wires shorten, allowing the module to bend. The return to undeformed conditions is achieved in calm air and is guaranteed by the elastic bias force exerted by the central rod. This article presents the basic concept of the module and a simple mathematical model for the design of the device. Experimental tests were carried out on three prototypes with bodies made of different materials. The results of these tests confirm the need to reduce the antagonistic action of the inactive SMA wires and led to the realization of a fourth prototype equipped with an additional SMA wire-driven locking/unlocking device for these wires. The preliminary results of this last prototype are encouraging.