Aykut Arif Topcu

Dr. Aykut Arif Topcu

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2017 in Journal of Biomaterials Science, Polymer Edition
Verified
Journal Article
Closed access
PÖPınar Öncel
Pınar Öncel
KÇKemal Çetin
Kemal Çetin
ATAykut Arif Topcu
Aykut Arif Topcu
HYHandan Yavuz
Handan Yavuz
Adil DenizliAdil Denizli
Adil Denizli
In this study, cryogel-based implantable molecularly imprinted drug delivery systems were designed for the delivery of antineoplastic agent. Mitomycin C imprinted poly(2-hydroxyethyl methacrylate-N-methacryloyl-l-glutamic acid) cryogel membranes were produced by free-radical bulk polymerization under partially frozen conditions. The membranes were characterized by swelling tests, Fourier transform infrared spectroscopy, scanning electron microscopy, surface area measurements and in vitro hemocompatibility tests. In vitro delivery studies were carried out to examine the effects of cross-linker ratio and template content. Mitomycin C imprinted cryogel membranes have megaporous structure (10–100 μm in diameter). The cumulative release of mitomycin C was decreased with increasing cross-linking agent ratio and increased with the amount of template in the cryogel structure. The nature of transport mechanism of the mitomycin C from the membranes was non-Fickian.

1 May 2019 in Materials Science and Engineering: B
Verified
Journal Article
Closed access
ATAykut Arif Topcu
Aykut Arif Topcu
EÖErdoğan Özgür
Erdoğan Özgür
FYFatma Yılmaz
Fatma Yılmaz
NBNilay Bereli
Nilay Bereli
ADAdil Denizli
Adil Denizli

29 January 2020 in Gels
Verified
Journal Article
Open access
PDF file
MBMonireh Bakhshpour-Yucel
Monireh Bakhshpour-Yucel
ATAykut Arif Topcu
Aykut Arif Topcu
NBNilay Bereli
Nilay Bereli
MAMehmet Hüseyin Alkan
Mehmet Hüseyin Alkan
Adil DenizliAdil Denizli
Adil Denizli
Human immunoglobulin M (hIgM) antibodies are considered as hopeful tools for diseases therapy. Therefore, chromatography approaches are used to purify hIgM with a single step. In this study, we prepared a poly(hydroxyethyl methacrylate) based immunoaffinity p(HEMA-I) cryogel column by using cyanamide to immobilize antihuman immunoglobulin on the p(HEMA) cryogel for purification of hIgM in aqueous solution and artificial human plasma. The characterization of the p(HEMA) cryogel column was performed by using a scanning electron microscope (SEM), micro-computerized tomography (µ-CT), Fourier transform infrared spectroscopy (FTIR), swelling degree and macro-porosity. Further, the optimizations of various parameters were performed such as, pH, ionic strength, temperature and concentration of hIgM in aqueous solutions. In addition, the Langmuir adsorption model was supported by experimental results. Maximum adsorbed amount of hIgM corresponded to 11.1 mg/g at pH 5.75 [morpholino ethanesulfonic acid (MES buffer)]. Our results indicated that the p(HEMA-I) cryogel column can be reused at least 10 times without significant loss in adsorption capacity. As a natural source, artificial human plasma was selected for hIgM adsorption and the purity of hIgM was evaluated using sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE).

10 September 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
NBNilay Bereli
Nilay Bereli
MBMonireh Bakhshpour-Yucel
Monireh Bakhshpour-Yucel
ATAykut Arif Topcu
Aykut Arif Topcu
Adil DenizliAdil Denizli
Adil Denizli
In this work, a surface plasmon resonance (SPR) based immunosensor was prepared by the immobilization of the amine-functionalized gold nanoparticles (N-AuNPs) on the sensing surface to sense immunoglobulin M (IgM) antibodies in the aqueous solution and artificial plasma. The characterization studies of SPR based immunosensor for IgM detection were performed with scanning electron microscope (SEM), contact angle measurements, and ellipsometry. Kinetic studies for the IgM immunosensor were carried out in the range of 1.0 to 200 ng/mL IgM concentrations in an aqueous solution. The total IgM analysis time including adsorption, desorption, and regeneration cycles was nearly 10 min for the prepared immunosensor. The limit of detection (LOD) and limit of quantification (LOQ) were found as 0.08 and 0.26 ng/mL, respectively. The reusability of the proposed immunosensor was tested with 6 consecutive adsorption-desorption, and regeneration cycles. Also, enzyme-linked immunosorbent assay (ELISA) method was utilized in the validation of the immunosensor.

6 February 2015 in Industrial & Engineering Chemistry Research
Verified
Journal Article
Closed access
BTBekir Tabaklı
Bekir Tabaklı
ATAykut Arif Topcu
Aykut Arif Topcu
SDSerhat Döker
Serhat Döker
LULokman Uzun
Lokman Uzun

13 July 2017 in Journal of Macromolecular Science, Part A
Verified
Journal Article
Closed access
ATAykut Arif Topcu
Aykut Arif Topcu
NBNilay Bereli
Nilay Bereli
IAİrfan Albayrak
İrfan Albayrak
Adil DenizliAdil Denizli
Adil Denizli
Creatinine imprinted cryogel (MIP) cartridge was prepared with functional monomer N-methacryloyl-(L)-histidinemethylester (MAH) under frozen conditions. Creatinine adsorption studies and selectivity of MIP cryogel were evaluated in aqueous solution and artificial urine sample. Maximum adsorbed amount of creatinine was calculated as 6.83 mg/g polymer for MIP cryogel. Langmuir and Freundlich adsorption isotherm models were used to investigate the adsorption behaviour of creatinine. In the artificial urine sample; recovery amounts of creatinine were found 34.7–46.2%. Creatinine imprinted cryogel (MIP) cartridge recognized creatinine, 4.58 and 4.37 times greater competitive molecules. MIP cryogel catridge was repeatedly used many times for adsorption desorption cycles.