The accuracy of piezoelectric test system has a direct influence on the accuracy of the vector force detection. Piezoelectric sensor parameters are obtained by calibration system calibrated through orthogonal calibration method. Accuracy of the application of field test lacks the corresponding theoretical basis, resulting in test system test accuracy is questioned. In this paper, piezoelectric force test system is used as the research object. In order to verify accuracy of piezoelectric test system through calibration of orthogonal calibration method, a variable angle deflection loading device was designed. An incremental calibration method for thrust test is put forward by applying vector force at different angles. Based on vector force coordinate transformation matrix, a deflection load test and analysis model are established. The vector force coordinates transformation matrix is used to calculate the experimental data obtained from the deviation angle test system, and the deviation of the vector force value is obtained. Finally, the accuracy, effectiveness and rationality of piezoelectric test system through the orthogonal calibration method are verified.

10 October 2019 in Journal of Dynamic Systems, Measurement, and Control
Verified
Journal Article
Closed access
PDF file
JZJun Zhang
Jun Zhang
JSJun Shao
Jun Shao
ZRZongjin Ren
Zongjin Ren
JYJing Yu
Jing Yu
XLXinyang Li
Xinyang Li
ZJZhenyuan Jia
Zhenyuan Jia
High-accuracy measurement of force affects real-time control and process adjustment of industrial production. Piezoelectric sensor can be applied to measure force with the characteristics of high frequency and stiffness, great dynamic response and resistance to harsh conditions. As an important part of test, calibration determines sensitivity coefficient which directly affects test accuracy. To improve the calibration accuracy of offset loading force for multisensor piezoelectric dynamometer, a novel calibration method using sensor sensitivity difference is proposed in this paper. The calibration experiments of four sensors are performed to obtain the axial sensitivities and the force-to-electricity conversion coefficients. The multiple loading-point (MLP) calibration experiments of dynamometer are carried out, and the calibration results prove that the sensitivity difference of four sensors is the main reason affecting the calibration accuracy. The sensitivity difference calibration method (SDCM) is applied to the MLP calibration experiments, and the results show that the average resultant force deviations are reduced from 418.79 N (8.38% full scare (FS) to 24.16 N (0.61% FS) under a loading force of 5000 N, which proves high accuracy and reliability of SDCM. The calibration method will provide guidance for improving the calibration accuracy of dynamometer.