Yukitaka Ohashi

Dr. Yukitaka Ohashi

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2007 in Journal of Applied Meteorology and Climatology
Verified
Journal Article
Open access
PDF file
YOYukitaka Ohashi
Yukitaka Ohashi
YGYutaka Genchi
Yutaka Genchi
HKHiroaki Kondo
Hiroaki Kondo
YKYukihiro Kikegawa
Yukihiro Kikegawa
HYHiroshi Yoshikado
Hiroshi Yoshikado
YHYujiro Hirano
Yujiro Hirano
A coupled model consisting of a multilayer urban canopy model and a building energy analysis model has been developed to investigate the diurnal variations of outdoor air temperature in the office areas of Tokyo, Japan. Observations and numerical experiments have been performed for the two office areas in Tokyo. The main results obtained in this study are as follows. The coupled model has accurately simulated the air temperature for a weekday case in which released waste heat has been calculated from the energy consumption and cooling load in the buildings. The model has also simulated the air temperature for a holiday case. However, the waste heat from the buildings has little influence on the outdoor temperatures and can be neglected because of the low working activity in the buildings. The waste heat from the air conditioners has caused a temperature rise of 1°–2°C or more on weekdays in the Tokyo office areas. This heating promotes the heat-island phenomenon in Tokyo on weekdays. Thus, it is shown that the energy consumption process (mainly with air conditioning) in buildings should be included in the modeling of summertime air temperature on weekdays in urban areas.

1 January 2020 in Environmental Research Communications
Verified
Journal Article
Open access
PDF file
YTYuya Takane
Yuya Takane
YOYukitaka Ohashi
Yukitaka Ohashi
CGC Sue B Grimmond
C Sue B Grimmond
MHMasayuki Hara
Masayuki Hara
YKYukihiro Kikegawa
Yukihiro Kikegawa
Future heat stress under six future global warming (ΔT GW ) scenarios (IPCC RCP8.5) in an Asian megacity (Osaka) is estimated using a regional climate model with an urban canopy and air-conditioning (AC). An urban heat ‘stress’ island is projected in all six scenarios (ΔT GW = +0.5 to +3.0 °C in 0.5 °C steps). Under ΔT GW = +3.0 °C conditions, people outdoors experience ‘extreme’ heat stress, which could result in dangerously high increases in human body core temperature. AC-induced feedback increases heat stress roughly linearly as ΔT GW increases, reaching 0.6 °C (or 12% of the heat stress increase). As this increase is similar to current possible heat island mitigation techniques, this feedback needs to be considered in urban climate projections, especially where AC use is large.

30 March 2018 in International Journal of Biometeorology
Verified
Journal Article
Closed access
YOYukitaka Ohashi
Yukitaka Ohashi
TKTakumi Katsuta
Takumi Katsuta
HTHaruka Tani
Haruka Tani
TOTaiki Okabayashi
Taiki Okabayashi
SMSatoshi Miyahara
Satoshi Miyahara
RMRyoji Miyashita
Ryoji Miyashita

29 September 2011 in International Journal of Biometeorology
Verified
Journal Article
Closed access
PDF file
YOYukitaka Ohashi
Yukitaka Ohashi
HKHiroshi Kawakami
Hiroshi Kawakami
YSYoshinori Shigeta
Yoshinori Shigeta
HIHiroshi Ikeda
Hiroshi Ikeda
NYNobuko Yamamoto
Nobuko Yamamoto

29 October 2021 in Geohazards
Verified
Journal Article
Open access
PDF file
YIYuki Iwamoto
Yuki Iwamoto
YOYukitaka Ohashi
Yukitaka Ohashi
This study provides a decade-long link between summer heatstroke incidence and certain heat stress indices in 47 prefectures of Japan. The results for each prefecture were determined from the age-adjusted heatstroke incidence rate (TRadj) with heatstroke patients transported by ambulance, as well as from the daily maximum temperature (TEMPmax), maximum wet-bulb globe temperature (WBGTmax), and maximum universal thermal climate index (UTCImax) recorded from July to September of 2010–2019. The UTCImax relatively increased the vulnerability in many prefectures of northern Japan more distinctly than the other indices. In the following analysis, the ratio of the TRadj of the hottest to coolest months using the UTCImax was defined as the heatstroke risk of the hottest to coolest (HRHC). Overall, the HRHC varied approximately from 20 to 40 in many prefectures in the past decade. In contrast, for the same analysis performed in each month, HRHC ratios in July and August fell within 2–4 in many prefectures, whereas in September, the average and maximum HRHC ratios for all prefectures were 7.0 and 32.4, respectively. This difference can be related to the large difference in UTCImax between the maximum and minimum for a decade.

1 August 2013 in Journal of Applied Meteorology and Climatology
Verified
Journal Article
Open access
YTYuya Takane
Yuya Takane
YOYukitaka Ohashi
Yukitaka Ohashi
HKHiroyuki Kusaka
Hiroyuki Kusaka
YSYoshinori Shigeta
Yoshinori Shigeta
YKYukihiro Kikegawa
Yukihiro Kikegawa
The actual conditions of mesoscale summer high temperatures (HTs) recorded in the Osaka–Kyoto urban area of Japan were investigated using an observation network. The daytime temperatures observed on 10 HT events in this area were the highest in the southern area of Kyoto [area with no Automated Meteorological Data Acquisition System (AMeDAS) observation sites]. To quantitatively evaluate the formation mechanisms of HT events, a heat budget analysis on an atmospheric column was conducted using the Weather Research and Forecasting (WRF) model. The results showed that over the HT area the daytime column temperature increased as a result of sensible-heat diffusion generated from the urban surface at the contribution rate of 54% and as a result of the sensible-heat advection and diffusion supplied from the sides and at the top of the column at the rate of 46% of all sensible heat supplied. To clarify previously unreported effects of synoptic-scale winds under typical summer pressure patterns on the HT events, a sensitivity experiment with no surface heat fluxes, backward trajectory analysis, and Euler forward tracer analysis was performed. These analyses yielded the following findings: 1) sensible heat at the synoptic scale and/or mesoscale was transported from the tropics by circulation patterns along the edge of the Pacific high as well as from tropical cyclones that were present in the vicinity of Japan and 2) airflow over the Kii Mountains also contributes to the HT events.