Xu Qingwen

Mr. Xu Qingwen

Key Laboratory of Power System Intelligent Dispatch and Control of the Ministry of Education, Shandong University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XQXu Qingwen
Xu Qingwen
Yongji CaoYongji Cao
Yongji Cao
Hengxu ZhangHengxu Zhang
Hengxu Zhang
Wen ZhangWen Zhang
Wen Zhang
VTVladimir Terzija
Vladimir Terzija
Non-synchronous renewable energy sources (RESs) have strong volatility and low inertia, which brings about great challenges on the accommodation of RESs and the security and stability of power systems. This paper proposes a bi-level power system dispatch and control architecture based on the grid-friendly virtual power plant (GVPP), so as to accommodate RESs flexibly and securely. The typical dispatch and control system of the power system in China is presented, and the particular challenges stemming from non-synchronous RESs are analyzed. The functional requirements, concept, and fundamental design of the GVPP are provided, which is distinguished from traditional virtual power plants (VPPs) for its active participation in power system stability control. Based on the cloud platform, a bi-level dispatch and control architecture considering two objectives is established. First, in the inner level, the GVPP operates to promote the accommodation of RESs under normal condition. Then, from the perspective of out-level power systems, GVPPs serve as spinning reserves for power support under contingencies. Besides, the key problems to be solved in the development of the GVPP-based architecture are summarized. Although the architecture is proposed for the power system in China, it can be applied to any power systems with similar challenges.

10 October 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XQXu Qingwen
Xu Qingwen
Hengxu ZhangHengxu Zhang
Hengxu Zhang
Yongji CaoYongji Cao
Yongji Cao
HQHao Qin
Hao Qin
ZGZhimin Gao
Zhimin Gao
The transmission line parameters vary with the change of temperature, which has a significant impact on power system state estimation (SE). Based on the theory of electro-thermal coordination (ETC), this paper proposes two ETC-SE approaches with the consideration of transmission line temperature. The heat balance equation (HBE) is combined with the conventional weighted least square SE for establishing an ETC-SE model. Moreover, an augmented Jacobian ETC-SE approach is developed by integrating the HBE into pseudo measurements and the line temperature into state vectors. The Jacobian matrix is augmented correspondingly and the partial differential coefficients of measurements to line temperature are provided, which enables to calculate line temperature and voltage phasors simultaneously. Furthermore, in order to accelerate the solving process, an improved two-step ETC-SE algorithm is proposed, in which the SE and temperature estimation are decoupled and solved via alternate iteration. The effectiveness of the proposed ETC-SE approaches is verified by the IEEE 14-, 39-, and 118-bus systems. The results show that the proposed ETC-SE approach is effective to reduce the calculation errors and possesses good convergence performance with varying environmental circumstances and ill-conditioned branches.