Claire Turner

Dr. Claire Turner

School of Life, Health & Chemical Sciences, Open University, Milton Keynes, UK

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2014 in Metabolites
Verified
Journal Article
Open access
PDF file
Célia LourençoCélia Lourenço
Célia Lourenço
Claire TurnerClaire Turner
Claire Turner
Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. “Breath fingerprinting”, indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles.

18 June 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CBClaire A Batty
Claire A Batty
MCMichael Cauchi
Michael Cauchi
Célia LourençoCélia Lourenço
Célia Lourenço
JHJohn O Hunter
John O Hunter
Claire TurnerClaire Turner
Claire Turner
Diagnosis of colorectal cancer is an invasive and expensive colonoscopy, which is usually carried out after a positive screening test. Unfortunately, existing screening tests lack specificity and sensitivity, hence many unnecessary colonoscopies are performed. Here we report on a potential new screening test for colorectal cancer based on the analysis of volatile organic compounds (VOCs) in the headspace of faecal samples. Faecal samples were obtained from subjects who had a positive faecal occult blood sample (FOBT). Subjects subsequently had colonoscopies performed to classify them into low risk (non-cancer) and high risk (colorectal cancer) groups. Volatile organic compounds were analysed by selected ion flow tube mass spectrometry (SIFT-MS) and then data were analysed using both univariate and multivariate statistical methods. Ions most likely from hydrogen sulphide, dimethyl sulphide and dimethyl disulphide are statistically significantly higher in samples from high risk rather than low risk subjects. Results using multivariate methods show that the test gives a correct classification of 75% with 78% specificity and 72% sensitivity on FOBT positive samples, offering a potentially effective alternative to FOBT.

1 April 2019 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Open access
ASAmy Smart
Amy Smart
BCBen De Lacy Costello
Ben De Lacy Costello
PWPaul White
Paul White
MAMatthew Avison
Matthew Avison
CBClaire Batty
Claire Batty
Norman RatcliffeNorman Ratcliffe
Norman Ratcliffe
Antibiotic resistance is set to be an unprecedented threat to modern medicine. 'Sniffing' bacteria potentially offers a rapid way to determine susceptibility. A successful proof-of-principle study is described, using thermal desorption-gas chromatography-mass spectrometry (TDGCMS) to 'smell' cephalexin and ciprofloxacin resistant and sensitive Urinary Tract Infection (UTI)-causing bacteria. 578 peaks at unique retention times were detected from 86 chromatograms of 18 bacterial isolates (E. coli, K. pneumoniae and P. aeruginosa). The isolates were grown with and without the presence of antibiotic. Chi-square analysis found 9 compounds that differed significantly between cephalexin sensitive and resistant isolates, and 22 compounds that differed significantly between ciprofloxacin sensitive and resistant isolates, at p ≤ 0.05. When antibiotic was added to the media, more differences were found in the cephalexin group, attributed to lysis, but not in the ciprofloxacin group. Further work with large sample sizes will potentially enable the development of diagnostic algorithms using presence/absence of particular compounds of interest.

1 October 2017 in International Journal of Mass Spectrometry
Verified
Journal Article
Open access
DMDušan Materić
Dušan Materić
MLMatteo Lanza
Matteo Lanza
PSPhilipp Sulzer
Philipp Sulzer
JHJens Herbig
Jens Herbig
DBDan Bruhn
Dan Bruhn
Claire TurnerClaire Turner
Claire Turner

15 March 2016 in Bioanalysis
Verified
Journal Article
Open access
Claire TurnerClaire Turner
Claire Turner
Analysis of volatile organic compounds (VOCs) from breath or clinical samples for disease diagnosis is an attractive proposition because it is noninvasive and rapid. There are numerous studies showing its potential, yet there are barriers to its development. Sampling and sample handling is difficult, and when coupled with a variety of analytical instrumentation, the same samples can give different results. Background air and the environment a person has been exposed to can greatly affect the VOCs emitted by the body; however, this is not an easy problem to solve. This review investigates the use of VOCs in disease diagnosis, the analytical techniques employed and the problems associated with sample handling and standardization. It then suggests the barriers to future development.

11 December 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Célia LourençoCélia Lourenço
Célia Lourenço
DKDarren Kelly
Darren Kelly
JCJack Cantillon
Jack Cantillon
MCMichael Cauchi
Michael Cauchi
MYMarianne A. Yon
Marianne A. Yon
Claire TurnerClaire Turner
Claire Turner
The analysis of volatile organic compounds (VOCs) as a non-invasive method for disease monitoring, such as type 2 diabetes (T2D) has shown potential over the years although not yet set in clinical practice. Longitudinal studies to date are limited and the understanding of the underlying VOC emission over the age is poorly understood. This study investigated longitudinal changes in VOCs present in faecal headspace in two mouse models of T2D – Cushing’s syndrome and single Afmid knockout mice. Longitudinal changes in bodyweight, blood glucose levels and plasma insulin concentration were also reported. Faecal headspace analysis was carried out using selected ion flow tube mass spectrometry (SIFT-MS) and thermal desorption coupled to gas chromatography-mass spectrometry (TD-GC-MS). Multivariate data analysis of the VOC profile showed differences mainly in acetic acid and butyric acid able to discriminate the groups Afmid and Cushing’s mice. Moreover, multivariate data analysis revealed statistically significant differences in VOCs between Cushing’s mice/wild-type (WT) littermates, mainly short-chain fatty acids (SCFAs), ketones, and alcohols, and longitudinal differences mainly attributed to methanol, ethanol and acetone. Afmid mice did not present statistically significant differences in their volatile faecal metabolome when compared to their respective WT littermates. The findings suggested that mice developed a diabetic phenotype and that the altered VOC profile may imply a related change in gut microbiota, particularly in Cushing’s mice. Furthermore, this study provided major evidence of age-related changes on the volatile profile of diabetic mice.