This article analyzes the feasibility of using construction and demolition waste (expanded polystyrene, ceramic, and concrete waste) in a gypsum matrix to manufacture plaster for interior coatings or for prefabricated elements for interior partitions. To do this, several gypsum specimens were prepared (4 × 4 × 16 cm) incorporating different percentages of waste based on the weight of the gypsum (25%, 50%, and 75% of ceramic, concrete, and a mixture of both). Reference samples were also produced (without additions) to compare the results obtained. The compounds with the best performance were selected and lightened by preparing other samples in which 1/3 and 2/3 of the volume of ceramic, concrete, and mixed waste were replaced with expanded polystyrene (EPS). All samples were tested in the laboratory and the following physical and mechanical characteristics were determined: density, surface hardness, flexural strength, compressive strength, capillary water absorption, and thermal conductivity. Several applications were proposed for the selected compounds. A gypsum block with a sandwich configuration was obtained (40 × 20 × 10 cm) using the optimum compound. The block was further tested regarding its density and compression strength. A comparative analysis showed that it is possible to produce materials with a gypsum matrix by adding ceramic, concrete, and EPS waste, improving the behavior of the traditional gypsum and enabling them to be applied in various construction applications. These applications have a lower environmental impact than ordinary ones because they use less primary raw material, due to the reuse of waste.
Análisis del comportamiento térmico del Sistema SATE: Edificio rehabilitado en Madrid =Analysis of the thermal behaviour of the ETICS system: Rehabilitated building in Madrid
This study emerged from the necessity to analyze the most effective energy-saving strategies within the current real estate market and substantiate their application with empirical data. Undoubtedly, the adoption of External Thermal Insulation Composite Systems (ETICSs) stands out as one of the prevalent approaches. This article presents temperature-monitoring data collected on-site from the facades of two single-family homes initially constructed with identical compositions, materials, construction dates, locations, and orientations. The thermal envelope of one home underwent rehabilitation using the ETICS, while the other remained in its original state. Continuous temperature recordings on the southern and northwestern facades of both homes were conducted using thermocouples over a 15-day period. The data analysis yielded insights into facade performance before and after this rehabilitation approach. The findings suggest that the implementation of ETICS results in more stable interior temperatures, significantly reducing indoor temperatures in comparison to outdoor conditions, leading to a notable decrease in heat energy loss. Consequently, this research underscores the tangible benefits of employing ETICS in building rehabilitation, emphasizing its role as a passive energy-saving strategy. By demonstrating the positive impact on thermal performance and energy efficiency, this study reinforces the vital connection between research endeavors and sustainability objectives.
Se estudia la estructura de un chorro no isotérmico introducido en el interior de una celda de geometría sencilla, que representa una habitación a escala real, y el intercambio de calor por transporte turbulento asociado al chorro. Utilizando una base de datos de velocidad obtenida con anemómetros sónico y de hilo caliente, así como de temperatura con termopares, se calcula el número de Arquímedes (Ar), la anchura térmica del flujo (l m) y los números adimensionales de Rayleigh (Ra) y Nusselt (Nu). Se determina la intensidad de turbulencia y los flujos de momento y calor, realizando el análisis de la varianza con el objetivo de contrastar la dependencia considerada, entre estos parámetros, según criterios de significación estadística. Los resultados muestran el comportamiento de las fuerzas de origen térmico y de inercia están asociados al chorro y al transporte de calor de origen turbulento en el interior de la celda.