Zhong Ji

Dr. Zhong Ji


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SCShuo Chen
Shuo Chen
ZJZhong Ji
Zhong Ji
HWHaiyan Wu
Haiyan Wu
YXYingchao Xu
Yingchao Xu
Considering the existing issues of traditional blood pressure (BP) measurement methods and non-invasive continuous BP measurement techniques, this study aims to establish the systolic BP and diastolic BP estimation models based on machine learning using pulse transit time and characteristics of pulse waveform. In the process of model construction, the mean impact value method was introduced to investigate the impact of each feature on the models and the genetic algorithm was introduced to implement parameter optimization. The experimental results showed that the proposed models could effectively describe the nonlinear relationship between the features and BP and had higher accuracy than the traditional methods with the error of 3.27 ± 5.52 mmHg for systolic BP and 1.16 ± 1.97 mmHg for diastolic BP. Moreover, the estimation errors met the requirements of the Advancement of Medical Instrumentation and British Hypertension Society criteria. In conclusion, this study was helpful in promoting the practical application of methods for non-invasive continuous BP estimation models.

26 August 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
WZWentao Zhong
Wentao Zhong
ZJZhong Ji
Zhong Ji
CSChanglong Sun
Changlong Sun
In recent years, cerebral blood oxygen saturation has become a key indicator during the perioperative period. Cerebral blood oxygen saturation monitoring is conducive to the early diagnosis and treatment of cerebral ischemia and hypoxia. The present study discusses the three most extensively used clinical methods for cerebral blood oxygen saturation monitoring from different aspects: working principles, relevant parameters, current situations of research, commonly used equipment, and relative advantages of different methods. Furthermore, through comprehensive comparisons of the methods, we find that near-infrared spectroscopy (NIRS) technology has significant potentials and broad applications prospects in terms of cerebral oxygen saturation monitoring. Despite the current NIRS technology, the only bedside non-invasive cerebral oxygen saturation monitoring technology, still has many defects, it is more in line with the future development trend in the field of medical and health, and will become the main method gradually.

1 January 2018 in Technology and Health Care
Verified
Journal Article
Open access
PDF file
XTXia Tan
Xia Tan
ZJZhong Ji
Zhong Ji
YZYadan Zhang
Yadan Zhang
BACKGROUND: Non-invasive continuous blood pressure monitoring can provide an important reference and guidance for doctors wishing to analyze the physiological and pathological status of patients and to prevent and diagnose cardiovascular diseases in the clinical setting. Therefore, it is very important to explore a more accurate method of non-invasive continuous blood pressure measurement. OBJECTIVE: To address the shortcomings of existing blood pressure measurement models based on pulse wave transit time or pulse wave parameters, a new method of non-invasive continuous blood pressure measurement – the GA-MIV-BP neural network model – is presented. METHOD: The mean impact value (MIV) method is used to select the factors that greatly influence blood pressure from the extracted pulse wave transit time and pulse wave parameters. These factors are used as inputs, and the actual blood pressure values as outputs, to train the BP neural network model. The individual parameters are then optimized using a genetic algorithm (GA) to establish the GA-MIV-BP neural network model. RESULTS: Bland-Altman consistency analysis indicated that the measured and predicted blood pressure values were consistent and interchangeable. CONCLUSIONS: Therefore, this algorithm is of great significance to promote the clinical application of a non-invasive continuous blood pressure monitoring method.

23 July 2024 in APL Bioengineering
Verified
Journal Article
Open access
PDF file
GCGang Chen
Gang Chen
LZLinglin Zou
Linglin Zou
ZJZhong Ji
Zhong Ji
The demand for ambulatory blood pressure monitoring (ABPM) is increasing due to the global rise in cardiovascular disease patients. However, conventional ABPM methods are discontinuous and can disrupt daily activities and sleep patterns. Photoplethysmography (PPG) is gaining attention from researchers due to its simplicity, portability, affordability, and ease of signal acquisition. This paper critically examines the advancements achieved in the technology of PPG-guided noninvasive blood pressure (BP) monitoring and explores future opportunities. We have performed a literature search using the Web of Science and PubMed search engines, from January 2018 to October 2023, for PPG signal quality assessment (SQA), cuffless BP estimation using single PPG, and associations between circadian rhythm and BP. Based on this foundation, we first examine the impact of PPG signal quality on blood pressure estimation results while focusing on methods for assessing PPG signal quality. Subsequently, the methods documented for estimating cuff-free BP from PPG signals are summarized. Furthermore, the study examines how individual differences affect the accuracy of BP estimation, incorporating the factors that influence arterial blood pressure (ABP) and elucidating the impact of circadian rhythm on blood pressure. Finally, there will be a summary of the study's findings and suggestions for future research directions.

1 January 2018 in Technology and Health Care
Verified
Journal Article
Open access
PDF file
JDJuan Dai
Juan Dai
ZJZhong Ji
Zhong Ji
YDYubao Du
Yubao Du
SCShuo Chen
Shuo Chen
BACKGROUND: To improving the nursing level of diabetics, it is necessary to develop noninvasive blood glucose method. OBJECTIVE: In order to reduce the number of the near-infrared signal, consider the nonlinear relationship between the blood glucose concentration and near-infrared signal, and correct the individual difference and physiological glucose dynamic, 2 artificial neural networks (2ANN) combined with particle swarm optimization (PSO), named as PSO-2ANN, is proposed. METHOD: Two artificial neural networks (ANNs) are employed as the basic structure of the PSO-ANN model, and the weight coefficients of the two ANNs which represent the difference of individual and daily physiological rule are optimized by particle swarm optimization (PSO). RESULTS: Clarke error grid shows the blood glucose predictions are distributed in regions A and B, Bland-Altman analysis show that the predictions and measurements are in good agreement. CONCLUSIONS: The PSO-2ANN model is a nonlinear calibration strategy with accuracy and robustness using 1550-nm spectroscopy, which can correct the individual difference and physiological glucose dynamics.

15 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
HWHaiyan Wu
Haiyan Wu
ZJZhong Ji
Zhong Ji
MLMengze Li
Mengze Li
Blood pressure is an extremely important blood hemodynamic parameter. The pulse wave contains abundant blood-pressure information, and the convenience and non-invasivity of its measurement make it ideal for non-invasive continuous monitoring of blood pressure. Based on combined photoplethysmography and electrocardiogram signals, this study aimed to extract the waveform information, introduce individual characteristics, and construct systolic and diastolic blood-pressure (SBP and DBP) estimation models using the back-propagation error (BP) neural network. During the model construction process, the mean impact value method was employed to investigate the impact of each feature on the model output and reduce feature redundancy. Moreover, the multiple population genetic algorithm was applied to optimize the BP neural network and determine the initial weights and threshold of the network. Finally, the models were integrated for further optimization to generate the final individualized continuous blood-pressure monitoring models. The results showed that the predicted values of the model in this study correlated significantly with the measured values of the electronic sphygmomanometer. The estimation errors of the model met the Association for the Advancement of Medical Instrumentation (AAMI) criteria (the SBP error was 2.5909 ± 3.4148 mmHg, and the DBP error was 2.6890 ± 3.3117 mmHg) and the Grade A British Hypertension Society criteria.