The durability of concrete structures is often reduced owing to the corrosion of reinforcement in an aggressive environment. Ordinary reinforcement methods, such as wrapping section steel or steel plate, are also vulnerable to corrosion. Using 6061-T6 aluminium alloy as near-surface reinforcement of the concrete structure is a feasible method. In this study, the corrosion resistance of 6061-T6 aluminium alloy bars was studied by simulating the coastal environment, atmospheric environment, and concrete internal environment with chloride solution, simulated acid rain solution, and saturated Ca(OH)2 solution. The corrosion rate of the 6061-T6 aluminium alloy in the above environments was tested using a weight loss method, and its corrosion resistance was evaluated using the metal corrosion resistance classification standard. Based on the electrochemical reaction mechanism, the polarisation properties and AC impedance spectra of steel and 6061-T6 aluminium alloy were compared, and the corrosion resistance mechanisms of steel and the 6061-T6 aluminium alloy in the above corrosive environments were obtained. The results show that the 6061-T6 aluminium alloy has better corrosion resistance than steel bars in chloride and atmospheric environments, with corrosion currents of 0.012 and 0.037 µA·cm−2, and 8-day corrosion rates of 0.051 and 0.031 mm·a−1, respectively. However, owing to the activity of the aluminium alloy, its corrosion resistance in an alkaline environment inside concrete is poor; the corrosion current is 0.22 µA·cm−2 and the 8-day corrosion rate is 16.166 mm·a−1. The research results can provide a reference for applying aluminium alloy bars as external prestressed concrete bars and near-surface steel bars.
This study explores the flexural behavior of reinforced concrete (RC) columns strengthened with near surface mounted (NSM) shape memory alloy (SMA) bars or carbon fiber reinforced polymer (CFRP) bars. Seven RC column specimens were designed and fabricated to study the influence of different variables on the flexural response of the strengthened columns. These parameters include type of NSM reinforcement (SMA bars or CFRP bars), ratio of NSM reinforcement, and effect of CFRP jacketing. The columns were tested under cyclic lateral loading with constant axial force. The flexural behavior of each specimen was examined in terms of peak load, failure load, drift ratios, displacement ductility, stiffness degradation, energy dissipation, and seismic damage index. The experimental results indicate that strengthening of RC columns with NSM SMA or CFRP bars improves the flexural behavior of the columns through increasing the lateral load capacity, reducing the stiffness degradation and increasing the cumulative energy absorption up to failure. Further enhancement in the lateral response of RC columns was obtained by combining NSM bars and CFRP jacketing as the later provides an additional confinement to the critical sections of the test specimens.