Marcos Rojas-Cardenas

Marcos Rojas-Cardenas

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2011 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
MRMarcos Rojas-Cardenas
Marcos Rojas-Cardenas
IGIrina Graur
Irina Graur
PPPierre Perrier
Pierre Perrier
JMJ. Gilbert Meolans
J. Gilbert Meolans
Thermal transpiration is the macroscopic movement of rarefied gas molecules induced by a temperature gradient. The gas moves from the lower to the higher temperature zone. An original method is proposed here to measure the mean macroscopic movement of gas in the case of a long circular cross-section glass microtube onto which a gradient of temperature is applied. The mass flow rate and the thermomolecular pressure difference have been measured by monitoring the absolute pressure evolution in time at both ends of the capillary using high-speed response pressure gauges. Two gases, nitrogen and helium, are studied and three different temperature differences of 50, 60, and 70 °C are applied to the tube. The analyzed gas rarefaction conditions vary from transitional to slip regime.

1 July 2013 in Physics of Fluids
Verified
Journal Article
Closed access
MRMarcos Rojas-Cardenas
Marcos Rojas-Cardenas
IGIrina Graur
Irina Graur
PPPierre Perrier
Pierre Perrier
JMJ. Gilbert Méolans
J. Gilbert Méolans
Thermal transpiration is the macroscopic movement induced in a rarefied gas by a temperature gradient. The gas moves from the lower to the higher temperature zone. An original method is proposed here to measure the stationary mass flow rate of gas created by thermal transpiration in a micro-tube heated at its outlet. In addition, by means of a time-dependent study, parameters such as the pressure variation, the pressure variation speed, and the characteristic time of the system are analyzed. The experimental system is composed of a glass tube of circular cross section and two reservoirs positioned one at the inlet and one at the outlet of the capillary. The reservoirs are connected to two fast response time capacitance diaphragm gauges. By monitoring the pressure variation with time inside both reservoirs, it is possible to measure the macroscopic movement of the gas along the tube. Three gases, nitrogen, argon, and helium, are studied and three temperature differences ΔT = 37, 53.5, and 71 K are applied to the tube. The analyzed gas rarefaction conditions vary from near free molecular to slip regime. Finally, Poiseuille counter flows consistent with the experimental zero flow conditions of the thermal transpiration process are proved to be possible.

10 April 2014 in Journal of Fluid Mechanics
Verified
Journal Article
Closed access
PDF file
HYHiroki Yamaguchi
Hiroki Yamaguchi
MRMarcos Rojas-Cardenas
Marcos Rojas-Cardenas
PPPierre Perrier
Pierre Perrier
IGIrina Graur
Irina Graur
TNTomohide Niimi
Tomohide Niimi
A thermal transpiration flow through a single rectangular micro-channel was studied experimentally for various gas species, including all rare gases, in order to investigate the influence of gas species on the flow properties. The final equilibrium flow characteristics and relaxation time of the pressure variation were evaluated as functions of the rarefaction parameter. The thermal molecular pressure difference was well fitted by the log-normal distribution function, and its magnitude was found to be strongly dependent on the gas species: a larger pressure difference was obtained for molecules of smaller diameter. However, for the thermal molecular pressure ratio and the thermal molecular pressure exponent, which are dimensionless quantities, the dependence on the gas species was negligible. The relaxation time of the pressure variation was well normalized by the characteristic time of the system. The influence of the geometry was evaluated by comparing the present results, obtained for the case of a rectangular channel, with already published data obtained for the case of a circular cross-section tube. The comparison showed that these two geometrical configurations influence the fluid flow in equal manner, if appropriate geometrical parameters are used for their representation.

19 April 2017 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
MRMarcos Rojas-Cardenas
Marcos Rojas-Cardenas
ESErnane Silva
Ernane Silva
MHMinh-Tuan Ho
Minh-Tuan Ho
CDCesar J. Deschamps
Cesar J. Deschamps
Irina A. GraurIrina A. Graur
Irina A. Graur

13 May 2017 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
GTGiorgos Tatsios
Giorgos Tatsios
GQG. Lopez Quesada
G. Lopez Quesada
MRMarcos Rojas-Cardenas
Marcos Rojas-Cardenas
Lucien BaldasLucien Baldas
Lucien Baldas
Stéphane ColinStéphane Colin
Stéphane Colin
DVDimitris Valougeorgis
Dimitris Valougeorgis

1 May 2018 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
ESErnane Silva
Ernane Silva
CDCesar J. Deschamps
Cesar J. Deschamps
MRMarcos Rojas-Cardenas
Marcos Rojas-Cardenas
CBChristine Barrot-Lattes
Christine Barrot-Lattes
Lucien BaldasLucien Baldas
Lucien Baldas
Stéphane ColinStéphane Colin
Stéphane Colin