Longzhen Zheng

Prof. Longzhen Zheng


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Analytica Chimica Acta
Verified
Journal Article
Closed access
LZLongzhen Zheng
Longzhen Zheng
DYDan Ye
Dan Ye
LXLeyan Xiong
Leyan Xiong
JXJingpeng Xu
Jingpeng Xu
KTKun Tao
Kun Tao
JXJian Xia
Jian Xia

1 July 2011 in Talanta
Verified
Journal Article
Closed access
LZLongzhen Zheng
Longzhen Zheng
LXLeyan Xiong
Leyan Xiong
DZDan Zheng
Dan Zheng
YLYindi Li
Yindi Li
QLQiang Liu
Qiang Liu
JXJian Xia
Jian Xia

30 March 2010 in The Analyst
Verified
Journal Article
Closed access
PDF file
LZLongzhen Zheng
Longzhen Zheng
JLJunhua Li
Junhua Li
JXJingpeng Xu
Jingpeng Xu
LXLeyan Xiong
Leyan Xiong
DZDan Zheng
Dan Zheng
JXJian Xia
Jian Xia
A novel glucose biosensor was constructed by using ferrocene-carbonyl-β-cyclodextrin (FcCD) inclusive complex as electron-transfer mediator and carbon nanotubes (CNTs) as electron-transfer promoter. FcCD inclusive complex and glucose oxidase (GOx) were covalently bonded to CNTs by poly-L-lysine (PLL) to fabricate a glucose biosensor. The electrocatalytic oxidation of glucose at the biosensor occurred at low potential below 200 mV, avoiding the interference of the main interfering substances in real samples containing a 5-times higher concentration of L-cysteine, ascorbic acid, and uric acid. The biosensor showed fast response for glucose. A broad linear range of glucose concentration from 1.0 × 10−5 to 2.90 × 10−3 M was obtained and the detection limit was 2.2 × 10−6 M.

1 January 2014 in ECS Electrochemistry Letters
Verified
Journal Article
Open access
PDF file
LXLeyan Xiong
Leyan Xiong
LZLongzhen Zheng
Longzhen Zheng
JXJingpeng Xu
Jingpeng Xu
WLWen Liu
Wen Liu
XKXiaowei Kang
Xiaowei Kang
JXJian Xia
Jian Xia
A sensitive non-enzyme hydrogen peroxide (H2O2) sensor has been prepared based on Fe3O4/reduced graphene oxide (Fe3O4/RGO) nanocomposite material. The sensitivity of Fe3O4/RGO modified electrode toward the electrochemical reduction of H2O2 is higher than that of Fe3O4 or Fe3O4/GO modified electrodes. A linear range of H2O2 concentration is obtained from 5.0 × 10−7 to 3.0 × 10−3 M with a detection limit of 1.8 × 10−7 M (S/N=3). The Fe3O4/RGO modified electrode also exhibits high selectivity and stability in the detection of H2O2, which suggests that Fe3O4/RGO nanocomposite material provides a promising platform for the non-enzyme electrochemical sensor.

29 February 2008 in Electrochemistry Communications
Verified
Journal Article
Closed access
LZLongzhen Zheng
Longzhen Zheng
LXLeyan Xiong
Leyan Xiong
JLJunhua Li
Junhua Li
XLXinjia Li
Xinjia Li
JSJuan Sun
Juan Sun
JXJian Xia
Jian Xia

14 January 2010 in Environmental Chemistry Letters
Verified
Journal Article
Closed access
PDF file
LXLeyan Xiong
Leyan Xiong
LZLongzhen Zheng
Longzhen Zheng
JXJingpeng Xu
Jingpeng Xu
DZDan Zheng
Dan Zheng
JLJunhua Li
Junhua Li
JXJian Xia
Jian Xia