Green vehicles include electric vehicles, natural gas vehicles, fuel cell vehicles (FCV), and vehicles running on fuel such as a biodiesel or an ethanol blend. An FCV is equipped with a cylinder valve installed in an ultra-high pressure vessel to control the hydrogen flow. For this purpose, an optimum design of the solenoid actuator is necessary to ensure reliability when driving an FCV. In this study, an electromagnetic field analysis for ensuring reliable operation of the solenoid actuator was conducted by using Maxwell V15. The electromagnetic field analysis was performed by magneto static technique, according to the distance between magnetic poles, in order to predict the attraction force. Finally, the attraction force was validated through comparison between the Maxwell results and measurement results. From the results, the error of attraction force ranged from 2.33 to 3.85 N at testing conditions.
A pilot-operated solenoid valve is used to control ultra-high pressure vessels. However, it is difficult to understand its dynamic behavior because the valve operates under ultra-high pressure conditions and the driving unit moves in a multi-step fashion in a tight hidden space. This study aims to identify the system coefficient, especially the damping coefficient, required to analyze the dynamic behavior of a solenoid driving unit. Experiments to measure the dynamic behavior of the driving unit are conducted using two laser sensors and one accelerator. The damping coefficient is estimated using Matlab Simulink, by varying the damping coefficient to match the experimental results. The obtained system coefficients are modeled as equations of motion. It is verified that the valve motion consists of two sequential movements—Phase 1 by pilot plunger and Phase 2 by main plunger, pilot plunger, and the valve initiation time is as fast as 9.9 ms. The damping coefficient of each phase is estimated 0.001 N ∙ s/mm for Phase 1, 0.004 N ∙ s/mm for Phase 2.
The Kyropoulos (Ky) and Czochralski (Cz) methods of crystal growth are used for large-diameter single crystals. The seeding process in these methods must induce initial crystallization by initiating contact between the seed crystals and the surface of the melted material. In the Ky and Cz methods, the seeding process lays the foundation for ingot growth during the entire growth process. When any defect occurs in this process, it is likely to spread to the entire ingot. In this paper, a vision system was constructed for auto seeding and for observing the surface of the melt in the Ky method. An algorithm was developed to detect the time when the internal convection of the melt is stabilized by observing the shape of the spoke pattern on the melt material surface. Then, the vision system and algorithm were applied to the growth furnace, and the possibility of process automation was examined for sapphire growth. To confirm that the convection of the melt was stabilized, the position of the island (i.e., the center of a spoke pattern) was detected using the vision system and image processing. When the observed coordinates for the center of the island were compared with the coordinates detected from the image processing algorithm, there was an average error of 1.87 mm (based on an image with 1024 × 768 pixels).
12 March 2019 in Journal of Mechanical Science and Technology
The aim of this work was to develop an eddy current type pressure sensor and investigate its fundamental characteristics affected by the mechanical and electrical design parameters of sensor. The sensor has two key components, i.e., diaphragm and coil. On the condition that the outer diameter of sensor is 10 mm, two key parts should be designed so as to keep a good linearity and sensitivity. Experiments showed that aluminum is the best target material for eddy current detection. A round-grooved diaphragm is suggested in order to measure more precisely its deflection caused by applied pressures. The design parameters of a round-grooved diaphragm can be selected depending on the measuring requirements. A developed pressure sensor with diaphragm of t = 0.2 mm and w = 1.05 mm was verified to measure pressure up to 10 MPa with very good linearity and errors of less than 0.16%.