Matthias Koegl

Mr. Matthias Koegl


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2019 in Optics
Verified
Journal Article
Open access
PDF file
YMYogeshwar Nath Mishra
Yogeshwar Nath Mishra
AYAjeth Yoganantham
Ajeth Yoganantham
MKMatthias Koegl
Matthias Koegl
LZLars Zigan
Lars Zigan
In this article, we compare absorption and temperature-dependent fluorescence spectra of five organic dyes for 2c-LIF (two-color laser-induced fluorescence) thermometry in ethanol and butanol. The dyes fluorescein, eosin Y, rhodamine B, rhodamine 6G, and sulforhodamine 101 individually mixed in ethanol and butanol were studied at liquid temperatures of 25–65 °C. The self-absorption spectral bands are analyzed along with intensity ratios and the respective sensitivities for one-dye and two-dye 2c-LIF thermometry are deduced. For one-dye 2c-LIF, rhodamine B showed the highest sensitivity of 2.93%/°C and 2.89%/°C in ethanol and butanol, respectively. Sulforhodamine 101 and rhodamine 6G showed the least sensitivities of 0.51%/°C and 1.24%/°C in ethanol and butanol, respectively. For two-dye 2c-LIF, rhodamine B/sulforhodamine 101 exhibited the highest temperature sensitivities of 2.39%/°C and 2.54%/°C in ethanol and butanol, respectively. The dye pair eosin Y/sulforhodamine 101 showed the least sensitivities of 0.15%/°C and 0.27%/°C in ethanol and butanol, respectively.

24 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MKMatthias Koegl
Matthias Koegl
CMChristopher Mull
Christopher Mull
KBKevin Baderschneider
Kevin Baderschneider
JWJan Wislicenus
Jan Wislicenus
SWStefan Will
Stefan Will
LZLars Zigan
Lars Zigan
Suitable fluorescence tracers (“dyes”) are needed for the planar measurement of droplet sizes by using a combination of laser-induced fluorescence (LIF) and Mie scattering. Currently, no suitable tracers have been characterized for application in planar droplet sizing in gasoline and kerosene fuels, as well as biofuel blends. One promising tracer is nile red, which belongs to the fluorophore group. For its utilization for droplet size measurements, preliminary characterization of the fluorescence of the respective fuel tracer mixtures are mandatory. For this purpose, the fluorescence and absorption behavior of nile red dissolved in the surrogate fuels Toliso and Jet A-1 as well as in biofuel blends was investigated. The fluorescence signal for nile red that was dissolved in the two base fuels Toliso and Jet A-1 showed a linear behavior as a function of dye concentration. The temperature effect on spectral absorption and emission of nile red was investigated in a specially designed test cell. An ethanol admixture to Toliso led to a spectral shift towards higher wavelengths. The absorption and emission bands were shifted towards lower wavelengths with increasing temperature for all fuels. Both absorption and fluorescence decreased with increasing temperature for all fuels, except for E20, which showed an increased fluorescence signal with increasing temperature. Jet A-1 and its blends with hydroprocessed esters and fatty acids (HEFA) and farnesane did not exhibit explicit variations in spectral absorption or emission, but these blends showed a more distinct temperature dependence compared to the Toliso-ethanol-blends. The effect of photo-dissociation of the LIF signal of the fuel tracer mixtures was studied, and all fuel mixtures besides Toliso showed a more or less distinct decay in the fluorescence signal with time. In summary, all investigated fuel-tracer mixtures are suitable for LIF/Mie ratio droplet sizing in combination with nile red at moderate temperatures and low evaporation cooling rates.

16 November 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
MKMatthias Koegl
Matthias Koegl
BHBernhard Hofbeck
Bernhard Hofbeck
KBKevin Baderschneider
Kevin Baderschneider
YMYogeshwar Nath Mishra
Yogeshwar Nath Mishra
FHFranz J. T. Huber
Franz J. T. Huber
LZLars Zigan
Lars Zigan
Planar droplet sizing (PDS) is a technique relying on the assumption that laser-induced fluorescence (LIF) and Mie scattering optical signals from spherical droplets depend on their volume and surface area, respectively. In this article, we verify the validity of this assumption by experimentally analyzing the light intensity of the LIF and Mie optical signals from micrometric droplets as a function of their diameter. The size of the droplets is controlled using a new flow-focusing monodisperse droplet generator capable of producing droplets of the desired size in the range of 21 µm to 60 µm. Ethanol droplets doped with eosin dye and excited at 532 nm are considered in this study, and the individual droplets were imaged simultaneously at microscopic and macroscopic scale. The effects of laser power, dye concentration, and temperature variation are systematically studied as a function of LIF/Mie ratio in the whole range of droplet sizes. Finally, a calibration curve at tracer concentration of 0.5 vol% is deduced and used to extract the droplet Sauter mean diameter (SMD) from instantaneous images of a transient ethanol spray. This droplet size mapping is done using structured laser illumination planar imaging (SLIPI), in order to suppress the artifacts induced by multiple light scattering.

22 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MKMatthias Koegl
Matthias Koegl
CWChristoph Weiß
Christoph Weiß
LZLars Zigan
Lars Zigan
Laser-induced fluorescence (LIF) spectroscopy using dyes is frequently applied for characterization of liquids and two-phase flows. The technique is utilized e.g., for mixing studies, thermometry, or droplet sizing. One major application of the LIF technique combined with Mie-scattering is the planar measurement of droplet sizes in spray systems. However, its uncertainty is determined, among others, by varying dye concentration and temperature changes occurring during mixing and droplet evaporation. Systematic experimental investigations are necessary to determine the influence of dye enrichment effects on the LIF-signal of single droplets. For these investigations, the fluorescence dye Eosin-Y is dissolved in water and ethanol, which are typical solvents and working fluids in bio-medical applications and power engineering. A photo-physical characterization of the mixtures under various conditions was conducted using a spectrometric LIF setup and a micro cell. For ethanol, a small temperature dependency of the Eosin-Y LIF signal is observed up to 373 K. Photo-dissociation of Eosin-Y is negligible for solution in ethanol while it is distinct in water. The LIF signals of the single droplets are studied with an acoustic levitator. Effects of droplet evaporation, droplet deformation and varying dye concentration on the LIF-signal are studied. The single droplet measurements revealed a complex change of the fluorescence signal with reduced droplet size. This is due to droplet deformations leading to variations in the internal illumination field as well as dye enrichment during evaporation.

9 September 2020 in Experiments in Fluids
Verified
Journal Article
Open access
PDF file
MKMatthias Koegl
Matthias Koegl
YMYogeshwar Nath Mishra
Yogeshwar Nath Mishra
KBKevin Baderschneider
Kevin Baderschneider
CCChris Conrad
Chris Conrad
BLBastian Lehnert
Bastian Lehnert
LZLars Zigan
Lars Zigan
A novel planar droplet sizing (PDS) technique based on laser-induced fluorescence (LIF) and Mie-scattering is utilized for the characterization of the spray structure under gasoline direct-injection spark-ignition (DISI) conditions. Fuel effects on the spray structure and cyclic variations are studied for a gasoline surrogate fuel (Toliso, consisting of 65 vol.% isooctane and 35 vol.% toluene) and the gasoline-ethanol blend E20 (20 vol.% ethanol admixture). Sauter mean diameter (SMD) results are compared with those from phase-Doppler anemometry (PDA) measurements showing good agreement especially at early points in time (up to 1.2 ms after start of injection). The liquid spray propagation and SMD are very similar for both fuels indicating similar atomization behavior. Both investigated fuels show comparable cyclic variations of the spray shape. A larger width and slightly larger droplet sizes are observed for the E20 spray when stronger evaporation occurs (at 2 ms). At these later points in time, the PDS-measured droplet sizes differ from the PDA-results. Here the limitation of the PDS-technique becomes obvious as a partial evaporation of the droplets may lead to large systematic errors. A numerical simulation of single droplets is provided for clarification of issues of droplet evaporation in PDS. Graphic

8 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MKMatthias Koegl
Matthias Koegl
MQMohammad Qomi
Mohammad Qomi
LZLars Zigan
Lars Zigan
In this work, the possibility of using a two-color LIF (laser-induced fluorescence) approach for fuel composition and temperature measurements using nile red dissolved in n-decane/butanol blends is investigated. The studies were conducted in a specially designed micro cell enabling the detection of the spectral LIF intensities over a wide range of temperatures (283–423 K) and butanol concentrations (0–100 vol.%) in mixtures with n-decane. Furthermore, absorption spectra were analyzed for these fuel mixtures. At constant temperature, the absorption and LIF signals exhibit a large spectral shift toward higher wavelengths with increasing butanol concentration. Based on this fact, a two-color detection approach is proposed that enables the determination of the butanol concentration. This is reasonable when temperature changes and evaporation effects accompanied with dye enrichment can be neglected. For n-decane, no spectral shift and broadening of the spectrum are observed for various temperatures. However, for butanol admixture, two-color thermometry is possible as long as the dye and butanol concentrations are kept constant. For example, the LIF spectrum shows a distinct broadening for B20 (i.e., 80 vol.% n-decane, 20 vol.% butanol) and a shift of the peak toward lower wavelengths of about 40 nm for temperature variations of 140 K.