Valeriya Perekatova

Dr. Valeriya Perekatova


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Photoacoustics
Verified
Journal Article
Open access
Mikhail KirillinMikhail Kirillin
Mikhail Kirillin
VPValeriya Perekatova
Valeriya Perekatova
ITIlya Turchin
Ilya Turchin
PSPavel Subochev
Pavel Subochev
Modern optical imaging techniques demonstrate significant potential for high resolution in vivo angiography. Optoacoustic angiography benefits from higher imaging depth as compared to pure optical modalities. However, strong attenuation of optoacoustic signal with depth provides serious challenges for adequate 3D vessel net mapping, and proper compensation for fluence distribution within biotissues is required. We report on the novel approach allowing to estimate effective in-depth fluence profiles for optoacoustic systems. Calculations are based on Monte Carlo simulation of light transport and account for complex illumination geometry and acoustic detection parameters. The developed fluence compensation algorithm was tested in in vivo angiography of human palm and allowed to overcome significant in-depth attenuation of probing radiation and enhance the contrast of lower dermis plexus while preserving high resolution of upper plexus imaging.

13 September 2016 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
VPValeriya Perekatova
Valeriya Perekatova
PSPavel Subochev
Pavel Subochev
MKMikhail Kleshnin
Mikhail Kleshnin
ITIlya Turchin
Ilya Turchin
The non-invasive measurement of blood oxygen saturation in blood vessels is a promising clinical application of optoacoustic imaging. Nevertheless, precise optoacoustic measurements of blood oxygen saturation are limited because of the complexities of calculating the spatial distribution of the optical fluence. In the paper error in the determination of blood oxygen saturation, associated with the use of approximate methods of optical fluence evaluation within the blood vessel, was investigated for optoacoustic measurements at two wavelengths. The method takes into account both acoustic pressure noise and the error in determined values of the optical scattering and absorption coefficients used for the calculation of the fluence. It is shown that, in conditions of an unknown (or partially known) spatial distribution of fluence at depths of 2 to 8 mm, minimal error in the determination of blood oxygen saturation is achieved at wavelengths of 658 ± 40 nm and 1069 ± 40 nm.

26 January 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
VPValeriya Perekatova
Valeriya Perekatova
AKAlexey Kostyuk
Alexey Kostyuk
Mikhail KirillinMikhail Kirillin
Mikhail Kirillin
ESEkaterina Sergeeva
Ekaterina Sergeeva
DKDaria Kurakina
Daria Kurakina
ITIlya Turchin
Ilya Turchin
We report on the comparative analysis of self-calibrating and single-slope diffuse reflectance spectroscopy in resistance to different measurement perturbations. We developed an experimental setup for diffuse reflectance spectroscopy (DRS) in a wide VIS-NIR range with a fiber-optic probe equipped with two source and two detection fibers capable of providing measurements employing both single- and dual-slope (self-calibrating) approaches. In order to fit the dynamic range of a spectrometer in the wavelength range of 460–1030 nm, different exposure times have been applied for short (2 mm) and long (4 mm) source-detector distances. The stability of the self-calibrating and traditional single-slope approaches to instrumental perturbations were compared in phantom and in vivo studies on human palm, including attenuations in individual channels, fiber curving, and introducing optical inhomogeneities in the probe–tissue interface. The self-calibrating approach demonstrated high resistance to instrumental perturbations introduced in the source and detection channels, while the single-slope approach showed resistance only to perturbations introduced into the source channels.

29 December 2021 in Photonics
Verified
Journal Article
Open access
PDF file
Pavel SubochevPavel Subochev
Pavel Subochev
FSFlorentin Spadin
Florentin Spadin
VPValeriya Perekatova
Valeriya Perekatova
AKAleksandr Khilov
Aleksandr Khilov
AKAndrey Kovalchuk
Andrey Kovalchuk
MJMichael Jaeger
Michael Jaeger
We propose a GPU-accelerated implementation of frequency-domain synthetic aperture focusing technique (SAFT) employing truncated regularized inverse k-space interpolation. Our implementation achieves sub-1s reconstruction time for data sizes of up to 100 M voxels, providing more than a tenfold decrease in reconstruction time as compared to CPU-based SAFT. We provide an empirical model that can be used to predict the execution time of quasi-3D reconstruction for any data size given the specifications of the computing system.

26 January 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
ITIlya Turchin
Ilya Turchin
VBVladimir V. Beschastnov
Vladimir V. Beschastnov
PPPetr Peretyagin
Petr Peretyagin
VPValeriya Perekatova
Valeriya Perekatova
AKAlexey Kostyuk
Alexey Kostyuk
Maksim G. RyabkovMaksim G. Ryabkov
Maksim G. Ryabkov
The aim of the study was to investigate the dynamics of the state of allo- and autografts of skin on a wound using optical modalities: diffuse reflectance spectroscopy (DRS), optical coherence tomography (OCT), and laser Doppler flowmetry (LDF). A deep thermal burn was simulated in 24 rats covering 20% of the body surface. On day 3 after the injury, a fascial necrectomy of two 500 mm2 areas on the left and right sides of the midline of the animal body were excised. Allografts and autografts were placed in the centers of these areas. Optical measurements of grafts were performed on the 0, 3rd, 6th, 10th, and 13th days after transplantation. The allografts demonstrated a pronounced decrease in oxygenation, blood content, and perfusion compared to autografts on the 6th day; in the following days of observation, these values returned to the average values of autografts. Water content gradually decreased from the beginning to the end of observation. In conclusion, optical diagnostics revealed changes in the morphological microstructure, the rate of restoration of blood circulation, and oxygen exchange in the early stages, specific for the allo- and autograft.

10 May 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DKDaria Kurakina
Daria Kurakina
Mikhail KirillinMikhail Kirillin
Mikhail Kirillin
VPValeriya Perekatova
Valeriya Perekatova
VPVladimir Plekhanov
Vladimir Plekhanov
AOAnna Orlova
Anna Orlova
THTayyaba Hasan
Tayyaba Hasan
Increase of the efficiency of photodynamic therapy (PDT) requires the development of advanced protocols employing both novel photosensitizer (PS) carriers and aids for online monitoring. Nanoconstructs may be comprised of a photosensitizer, chemotherapy drugs, or inhibitors of molecular pathways that support cancer growth. In this paper, we analyze the efficiency of a bimodal approach involving fluorescence and optoacoustic imaging in monitoring drug distribution and photobleaching. The study evaluates typical sensitivities of these techniques to the presence of the two key moieties of a nanoconstruct: benzoporphyrin derivatives (BPD) serving as a PS, and IRDye800 acting as a contrast agent. Both imaging modalities employ dual-wavelength probing at the wavelengths corresponding to absorption peaks of BPD and IRDye800, which enables their separate detection. In an experiment on a tissue-mimicking phantom with inclusions containing separate BPD and IRDye800 solutions, fluorescence imaging demonstrated higher contrast as compared to optoacoustic imaging for both components, though strong light scattering in the surrounding media restricted accurate localization of the markers. It was also sensitive to photobleaching, which is a measure of PDT efficiency. Optoacoustic imaging demonstrated sufficient sensitivity to both components, though less than that of fluorescence imaging, however, it enabled depth-resolved detection of an absorber and estimation of its relative content. Employment of the bimodal approach in monitoring of PS photobleaching adds to its potential in intraprocedural PDT monitoring.