Visal Raveendran

Mr. Visal Raveendran

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017
Verified
Conference Paper
Closed access
VRVisal Raveendran
Visal Raveendran
RDR. Divya
R. Divya
PCP. C. Sreya Chandran
P. C. Sreya Chandran
Manjula NairManjula Nair
Manjula Nair
The population of Electric Vehicle (EV) is tremendously increasing with the increase in fuel price and decrease in availability. As the number of EV increases, along with that the number of EV charging stations should also increase, which constitute a considerable charging impact on the grid from which the supply is taken. In this paper, in order to reduce this charging impact and its after effects, a topology for EV charging station is proposed which also promote the use of EVs. The proposed topology mainly consists of a charging station powered by the grid as well as the storage integrated solar PV system and a controller. The grid dependency of the charging station is reduced by using a renewable energy source (Solar PV) and for improving the system reliability a Battery Energy Storage System (BESS) is incorporated. The control technique helps to reduce the charging impact on the grid by controlling the charging current as per the system conditions. To make the EV Charging Station (EVCS) more customized, three different options (Quick, Green and Budget) for charging are given such that the customer is free to choose one among them according to his requirement. The cost of charging will vary according to the selected mode of charging. A smart Electric Vehicle charging station is designed and the charging current control in various grid conditions are tested and verified by u sing MATLAB Simulink model and the obtained results are included.

1 December 2017
Verified
Conference Paper
Closed access
VRVisal Raveendran
Visal Raveendran
NKN Navaneet Krishnan
N Navaneet Krishnan
Manjula NairManjula Nair
Manjula Nair
Electric Vehicle (EV) is anticipated to play an important role in urban transport in near future. The passion in the minds of many researchers for an eco-friendly transport medium with reduced dependency on fossil fuels have sparked a large-scale research shift towards EV and its promotion. It is one of the solutions for major issues owing to urban transport such as deteriorating air quality, rising green-house gas emissions and noise pollution. With the popularization of EVs, the research on EV charging stations (EVCS) has also boosted up and global standards have been set for charging with the help of EV manufacturers. This work aims at contributing towards the application of these EVCS installed at various locations in providing Vehicle-to-Grid (V2G) support along with vehicle charging to support the grid during different requirements. A specific c ase of EVCS i nstalled at Kochi Metro Rail System has been simulated where vehicle charging, harmonic elimination, and reactive power compensation is studied and the results are explained with the help of waveforms. A hardware setup has also been used to verify the simulation results.

3 January 2020 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
VRVisal Raveendran
Visal Raveendran
Manjula NairManjula Nair
Manjula Nair
With the growing popularity of electrified transportation across the world, there have been extensive reports of research involving plug‐in electric vehicles (PEVs), electric vehicle charging facilities (EVCFs) and their integration to the main electric grid, besides sustainable energy resources for powering these vehicles. This study proffers a power factor corrected level‐1 DC public green‐charging infrastructure accompanied by an integrated control, for electric light motor vehicles, compliant with recently formulated Indian charging standards. Power factor correction of plug‐in electric vehicle charging current, solar photo‐voltaic grid integration and charging of energy storage system is achieved using control of bidirectional AC/DC converters. A firmware and user interface for multimode off‐board DC charging, with green, fast and semi‐fast charging modes are investigated. Intelligent control for fast charging is also presented to reduce its pernicious impact on the grid. The simulation and hardware results verify the prime performance objectives of improving the local power quality and renewable energy utilisation with multimode charging, in the Indian context. The effectiveness of the proposed infrastructure is further demonstrated by a simulated use case, where 30 PEVs are randomly charged, in various modes, at this EVCF during busy commute hours.

1 July 2018
Verified
Conference Paper
Closed access
RSR S Sreelekshmi
R S Sreelekshmi
RAR Anusree
R Anusree
VRVisal Raveendran
Visal Raveendran
Manjula NairManjula Nair
Manjula Nair
The sudden rise in gasoline products makes the transportation sector hectic. So the gasoline transportation is replaced by electrified transportation. The usage of renewable energy sources and energy storage technologies are of great demand in electrified transportation. Individual energy storage systems cannot compensate efficiently the demand for power for an electric vehicle. So a solar fed integrated system of lithium-ion battery and supercapacitor in an electric vehicle is nominated in this paper. Hybrid energy storage system (HESS) is implemented by the charging and discharging of storage elements used. HESS enhances the whole performance and efficiency of electric powered vehicles. MATLAB and Proteus are the simulation platform used.

1 March 2014
Verified
Conference Paper
Closed access
VRVisal Raveendran
Visal Raveendran
Manjula NairManjula Nair
Manjula Nair
This paper describes the use of Electric Vehicle Charging Stations (SmartParks) as Shunt Active Filters (SAF) to provide Vehicle-to-Grid (V2G) services to the grid such as reactive power compensation and harmonic elimination. The bidirectional converters used in these parks are used to charge the batteries during off-peak hours, support the grid by providing compensation when demanded and also supply the stored renewable energy to the grid if the parks use solar energy for charging. The complete simulation of the hysteresis current controlled voltage source converter (VSC) acting as SmartPark is presented using modified ICosΦ controller. Simulations are performed in MATLAB for inductive and non-linear loads under steady state as well as transient conditions. Simulation results demonstrate the viability of this simple and efficient controller to be used as SAF.

1 July 2016
Verified
Conference Paper
Closed access
VRVisal Raveendran
Visal Raveendran
NKN. Navaneet Krishnan
N. Navaneet Krishnan
Manjula NairManjula Nair
Manjula Nair
Smart Park associated shunt active filter has the potential to support the main grid with respect to harmonic, reactive and active power needed by the load. By incorporating modified Icos φ controller, active power support capability of Smart Park is studied in accordance with the SOC of master battery and the source current as constraints. The results of simulation prove the effectiveness of active power compensation capability of Smart Park together with harmonic and reactive power compensation for a 750V DC metro traction system.