Arai Fumihito

Arai Fumihito

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2019 in Science Advances
Verified
Journal Article
Open access
PDF file
KHKotaro Hiramatsu
Kotaro Hiramatsu
TITakuro Ideguchi
Takuro Ideguchi
YYYusuke Yonamine
Yusuke Yonamine
SLSangWook Lee
SangWook Lee
YLYizhi Luo
Yizhi Luo
KGKeisuke Goda
Keisuke Goda
Flow cytometry is an indispensable tool in biology for counting and analyzing single cells in large heterogeneous populations. However, it predominantly relies on fluorescent labeling to differentiate cells and, hence, comes with several fundamental drawbacks. Here, we present a high-throughput Raman flow cytometer on a microfluidic chip that chemically probes single live cells in a label-free manner. It is based on a rapid-scan Fourier-transform coherent anti-Stokes Raman scattering spectrometer as an optical interrogator, enabling us to obtain the broadband molecular vibrational spectrum of every single cell in the fingerprint region (400 to 1600 cm−1) with a record-high throughput of ~2000 events/s. As a practical application of the method not feasible with conventional flow cytometry, we demonstrate high-throughput label-free single-cell analysis of the astaxanthin productivity and photosynthetic dynamics of Haematococcus lacustris.

10 September 2014 in Micromachines
Verified
Journal Article
Open access
PDF file
THTakeshi Hayakawa
Takeshi Hayakawa
SSShinya Sakuma
Shinya Sakuma
TFTakeshi Fukuhara
Takeshi Fukuhara
YYYoshiyuki Yokoyama
Yoshiyuki Yokoyama
AFArai Fumihito
Arai Fumihito
We propose a single cell extraction chip with an open structure, which utilizes vibration-induced whirling flow and a single cell catcher. By applying a circular vibration to a micropillar array spiral pattern, a whirling flow is induced around the micropillars, and target cells are transported towards the single cell catcher placed at the center of the spiral. The single cell catcher is composed of a single-cell-sized hole pattern of thermo-responsive gel. The gel swells at low temperatures (≲32 ◦C) and shrinks at high temperatures (≳32 ◦C), therefore, its volume expansion can be controlled by an integrated microheater. When the microheater is turned on, a single cell is trapped by the hole pattern of the single cell catcher. Then, when the microheater is turned off, the single cell catcher is cooled by the ambient temperature. The gel swells at this temperature, and the hole closes to catch the single cell. The caught cell can then be released into culture wells on a microtiter plate by heating the gel again. We conducted single cell extraction with the proposed chip and achieved a 60% success rate, of which 61% cells yielded live cells.

2 May 2010 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
YYYoko Yamanishi
Yoko Yamanishi
SSShinya Sakuma
Shinya Sakuma
KOKazuhisa Onda
Kazuhisa Onda
AFArai Fumihito
Arai Fumihito

1 November 2019 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
Lin FengLin Feng
Lin Feng
BSBin Song
Bin Song
YCYuanyuan Chen
Yuanyuan Chen
SLShuzhang Liang
Shuzhang Liang
YDYuguo Dai
Yuguo Dai
AFArai Fumihito
Arai Fumihito
The capability to precisely rotate cells and other micrometer-sized biological samples is invaluable in biomedicine, bioengineering, and biophysics. We propose herein a novel on-chip cell rotation method using acoustic microstreaming generated by oscillating asymmetrical microstructures. When the vibration is applied to a microchip with our custom-designed microstructures, two different modes of highly localized microvortices are generated that are utilized to precisely achieve in-plane and out-of-plane rotational manipulation of microbeads and oocytes. The rotation mechanism is studied and verified using numerical simulations. Experiments of the microbeads are conducted to evaluate the claimed functions and investigate the effects of various parameters, such as the frequency and the driving voltage on the acoustically induced flows. Accordingly, it is shown that the rotational speed and direction can be effectively tuned on demand in single-cell studies. Finally, the rotation of swine oocytes is involved as further applications. By observing the maturation stages of M2 after the exclusion of the first polar body of operated oocytes, the proposed method is proved to be noninvasive. Compared with the conventional approaches, our acoustofluidic cell rotation approach can be simple-to-fabricate and easy-to-operate, thereby allowing rotations irrespective of the physical properties of the specimen under investigation.

21 June 2013 in Micromachines
Verified
Journal Article
Open access
PDF file
Lin FengLin Feng
Lin Feng
MHMasaya Hagiwara
Masaya Hagiwara
AIAkihiko Ichikawa
Akihiko Ichikawa
AFArai Fumihito
Arai Fumihito
In this study, we developed a microfluidic chip with a magnetically driven microrobot for oocyte enucleation. A microfluidic system was specially designed for enucleation, and the microrobot actively controls the local flow-speed distribution in the microfluidic chip. The microrobot can adjust fluid resistances in a channel and can open or close the channel to control the flow distribution. Analytical modeling was conducted to control the fluid speed distribution using the microrobot, and the model was experimentally validated. The novelties of the developed microfluidic system are as follows: (1) the cutting speed improved significantly owing to the local fluid flow control; (2) the cutting volume of the oocyte can be adjusted so that the oocyte undergoes less damage; and (3) the nucleus can be removed properly using the combination of a microrobot and hydrodynamic forces. Using this device, we achieved a minimally invasive enucleation process. The average enucleation time was 2.5 s and the average removal volume ratio was 20%. The proposed new system has the advantages of better operation speed, greater cutting precision, and potential for repeatable enucleation.

29 March 2021 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
DCDixiao Chen
Dixiao Chen
ZYZiping Yang
Ziping Yang
YJYiming Ji
Yiming Ji
YDYuguo Dai
Yuguo Dai
Lin FengLin Feng
Lin Feng
AFArai Fumihito
Arai Fumihito
The magnetically actuated robot has valuable potential in biomedicine, bioengineering, and biophysics for its capability to precisely manipulate particles or biological tissues. However, the deformability of rigid robots with predetermined shapes is limited, which constricts their functions and causes inconvenience for robots' movement in constricted space. In this study, we proposed a feasible and efficient ferrofluid-based robot for the transportation of tiny particles and blocks. In addition, a method to generate a patterned magnetic field is also introduced to model a ferrofluid-based robot with an adaptive shape. Benefiting from the paramagnetism and fluidity of the ferrofluid-based robot, it also demonstrates outstanding motion accuracy and output force on a superhydrophobic surface. Because of its excellent motion characteristics, high motion accuracy, and high measured output force, the proposed ferrofluid-based robot has great advantages in the field of microoperation. The correlation coefficient between the motion trajectory of the ferrofluid-based robot and the motion trajectory of the micro-stages is 0.9967. The position error is less than 1.5% of the total stroke.