Background: Diagnosis of benign paroxysmal positional vertigo (BPPV) depends on the accurate interpretation of nystagmus induced by positional tests. However, difficulties in interpreting eye-movement often can arise in primary care practice or emergency room. We hypothesized that the use of machine learning would be helpful for the interpretation. Methods: From our clinical data warehouse, 91,778 nystagmus videos from 3467 patients with dizziness were obtained, in which the three-dimensional movement of nystagmus was annotated by four otologic experts. From each labeled video, 30 features changed into 255 grid images fed into the input layer of the neural network for the training dataset. For the model validation, video dataset of 3566 horizontal, 2068 vertical, and 720 torsional movements from 1005 patients with BPPV were collected. Results: The model had a sensitivity and specificity of 0.910 ± 0.036 and 0.919 ± 0.032 for horizontal nystagmus; of 0.879 ± 0.029 and 0.894 ± 0.025 for vertical nystagmus; and of 0.783 ± 0.040 and 0.799 ± 0.038 for torsional nystagmus, respectively. The affected canal was predicted with a sensitivity of 0.806 ± 0.010 and a specificity of 0.971 ± 0.003. Conclusions: As our deep-learning model had high sensitivity and specificity for the classification of nystagmus and localization of affected canal in patients with BPPV, it may have wide clinical applicability.
Motivation: The ability to accurately read the order of nucleotides in DNA and RNA is fundamental for modern biology. Errors in next-generation sequencing can lead to many artifacts, from erroneous genome assemblies to mistaken inferences about RNA editing. Uneven coverage in datasets also contributes to false corrections. Result: We introduce Trowel, a massively parallelized and highly efficient error correction module for Illumina read data. Trowel both corrects erroneous base calls and boosts base qualities based on the k -mer spectrum. With high-quality k -mers and relevant base information, Trowel achieves high accuracy for different short read sequencing applications.The latency in the data path has been significantly reduced because of efficient data access and data structures. In performance evaluations, Trowel was highly competitive with other tools regardless of coverage, genome size read length and fragment size. Availability and implementation: Trowel is written in C++ and is provided under the General Public License v3.0 (GPLv3). It is available at http://trowel-ec.sourceforge.net . Contact:euncheon.lim@tue.mpg.de or weigel@tue.mpg.de Supplementary information: Supplementary data are available at Bioinformatics online.
1 November 2019 in Clinical and Experimental Otorhinolaryngology
Even though vestibular rehabilitation therapy (VRT) using head-mounted display (HMD) has been highlighted recently as a popular virtual reality platform, we should consider that HMD itself do not provide interactive environment for VRT. This study aimed to test the feasibility of interactive components using eye tracking assisted strategy through neurophysiologic evidence. HMD implemented with an infrared-based eye tracker was used to generate a virtual environment for VRT. Eighteen healthy subjects participated in our experiment, wherein they performed a saccadic eye exercise (SEE) under two conditions of feedback-on (F-on, visualization of eye position) and feedback-off (F-off, non-visualization of eye position). Eye position was continuously monitored in real time on those two conditions, but this information was not provided to the participants. Electroencephalogram recordings were used to estimate neural dynamics and attention during SEE, in which only valid trials (correct responses) were included in electroencephalogram analysis. SEE accuracy was higher in the F-on than F-off condition (P=0.039). The power spectral density of beta band was higher in the F-on condition on the frontal (P=0.047), central (P=0.042), and occipital areas (P=0.045). Beta-event-related desynchronization was significantly more pronounced in the F-on (-0.19 on frontal and -0.22 on central clusters) than in the F-off condition (0.23 on frontal and 0.05 on central) on preparatory phase (P=0.005 for frontal and P=0.024 for central). In addition, more abundant functional connectivity was revealed under the F-on condition. Considering substantial gain may come from goal directed attention and activation of brain-network while performing VRT, our preclinical study from SEE suggests that eye tracking algorithms may work efficiently in vestibular rehabilitation using HMD.
Background: Eye movement tests remain significantly underutilized in emergency departments and primary healthcare units, despite their superior diagnostic sensitivity compared to neuroimaging modalities for the differential diagnosis of acute vertigo. This underutilization may be attributed to a potential lack of awareness regarding these tests and the absence of appropriate tools for detecting nystagmus. This study aimed to develop a nystagmus measurement algorithm using a lightweight deep-learning model that recognizes the ocular regions.Method: The deep learning model was used to segment the eye regions, detect blinking, and determine the pupil center. The model was trained using images extracted from video clips of a clinical battery of eye movement tests and synthesized images reproducing real eye movement scenarios using virtual reality. Each eye image was annotated with segmentation masks of the sclera, iris, and pupil, with gaze vectors of the pupil center for eye tracking. We conducted a comprehensive evaluation of model performance and its execution speeds in comparison to various alternative models using metrics that are suitable for the tasks.Results: The mean Intersection over Union values of the segmentation model ranged from 0.90 to 0.97 for different classes (sclera, iris, and pupil) across types of images (synthetic vs. real-world images). Additionally, the mean absolute error for eye tracking was 0.595 for real-world data and the F1 score for blink detection was ≥ 0.95, which indicates our model is performing at a very high level of accuracy. Execution speed was also the most rapid for ocular object segmentation under the same hardware condition as compared to alternative models. The prediction for horizontal and vertical nystagmus in real eye movement video revealed high accuracy with a strong correlation between the observed and predicted values (r = 0.9949 for horizontal and r = 0.9950 for vertical; both p < 0.05).Conclusion: The potential of our model, which can automatically segment ocular regions and track nystagmus in real time from eye movement videos, holds significant promise for emergency settings or remote intervention within the field of neurotology.
Background: Persistent postural–perceptual dizziness (PPPD) and motion sickness (MS) are associated with disturbances in spatial orientation related to altered multisensory integration. Impaired perception of upright orientation during head tilt may therefore occur in these conditions. Subjective visual vertical (SVV) and subjective visual horizontal (SVH) testing under head-tilted conditions provide quantitative measures of such perceptual errors. We hypothesized that headtilt–induced perceptual errors would be associated with PPPD and with susceptibility to clinically significant MS during non-driving tasks. Methods: 80 participants were enrolled: 27 healthy controls, 36 individuals with high Motion Sickness Susceptibility Questionnaire scores who reported MS during real-world driving, and 17 patients with PPPD diagnosed according to the Bárány Society criteria. SVV and SVH were measured at ±30° and ±60° head-roll tilts in a virtual environment. Perceptual error was defined as the signed deviation from the true vertical or horizontal orientation. Diagnostic accuracy was assessed using receiver operating characteristic analysis. Results: SVV and SVH errors under head-tilt conditions differed significantly between groups, with healthy controls showing contraversive deviations and both individuals with high-MS and patients with PPPD exhibiting ipsiversive deviations, particularly at ±60° roll tilts, whereas errors in the upright (0°) position were negligible. Several tilt conditions demonstrated excellent diagnostic accuracy (AUC ≥ 0.90). Real-world MS severity correlated with ipsiversive SVV errors but not with questionnaire-based susceptibility scores. Conclusions: Based on the present findings, further methodological refinement may allow head-tilt SVV/SVH testing to serve as a rapid and sensitive tool for detecting perceptual alterations underlying functional dizziness, with translational potential for MS risk screening in future autonomous vehicle environments.