Matthias Görges

Dr. Matthias Görges

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2009 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
Matthias GörgesMatthias Görges
Matthias Görges
BMBoaz A. Markewitz
Boaz A. Markewitz
DWDwayne R. Westenskow
Dwayne R. Westenskow
In an intensive care unit, alarms are used to call attention to a patient, to alert a change in the patient's physiology, or to warn of a failure in a medical device; however, up to 94% of the alarms are false. Our purpose in this study was to identify a means of reducing the number of false alarms. An observer recorded time-stamped information of alarms and the presence of health care team members in the patient room; each alarm response was classified as effective (action taken within 5 min), ineffective (no response to the alarm), and ignored (alarm consciously ignored or actively silenced). During the 200-h study period, 1271 separate entries by an individual to the room being observed were recorded, 1214 alarms occurred and 2344 tasks were performed. On average, alarms occurred 6.07 times per hour and were active for 3.28 min per hour; 23% were effective, 36% were ineffective, and 41% were ignored. The median alarm duration was 17 s. A 14-s delay before alarm presentation would remove 50% of the ignored and ineffective alarms, and a 19-s delay would remove 67%. Suctioning, washing, repositioning, and oral care caused 152 ignored or ineffective ventilator alarms. Introducing a 19-s alarm delay and automatically detecting suctioning, repositioning, oral care, and washing could reduce the number of ineffective and ignored alarms from 934 to 274. More reliable alarms could elicit more timely response, reduce workload, reduce noise pollution, and potentially improve patient safety.

1 March 2012 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
DLDavid Liu
David Liu
Matthias GörgesMatthias Görges
Matthias Görges
SJSimon A. Jenkins
Simon A. Jenkins
Data recorded from the devices used to monitor a patient's vital signs are often used in the development of displays, alarms, and information systems, but high-resolution, multiple-parameter datasets of anesthesia monitoring data from patients during anesthesia are often difficult to obtain. Existing databases have typically been collected from patients in intensive care units. However, the physical state of intensive care patients is dissimilar to those undergoing surgery, more frequent and marked changes to cardiovascular and respiratory variables are seen in operating room patients, and additional and highly relevant information to anesthesia (e.g., end-tidal agent monitoring, etc.) is omitted from these intensive care databases. We collected a set of high-quality, high-resolution, multiple-parameter monitoring data suitable for anesthesia monitoring research. Vital signs data were recorded from patients undergoing anesthesia at the Royal Adelaide Hospital. Software was developed to capture, time synchronize, and interpolate vital signs data from Philips IntelliVue MP70 and MP30 patient monitors and Datex-Ohmeda Aestiva/5 anesthesia machines into 10 millisecond resolution samples. The recorded data were saved in a variety of accessible file formats. Monitoring data were recorded from 32 cases (25 general anesthetics, 3 spinal anesthetics, 4 sedations) ranging in duration from 13 minutes to 5 hours (median 105 min). Most cases included data from the electrocardiograph, pulse oximeter, capnograph, noninvasive arterial blood pressure monitor, airway flow, and pressure monitor and, in a few cases, the Y-piece spirometer, electroencephalogram monitor, and arterial blood pressure monitor. Recorded data were processed and saved into 4 file formats: (1) comma-separated values text files with full numerical and waveform data, (2) numerical parameters recorded in comma-separated values files at 1-second intervals, (3) graphical plots of all waveform data in a range of resolutions as Portable Network Graphics image files, and (4) graphical overview plots of numerical data for entire cases as Portable Network Graphics and Scalable Vector Graphics files. The complete dataset is freely available online via doi:102.100.100/6914 and has been listed in the Australian National Data Service Collections Registry. The present dataset provides clinical anesthesia monitoring data from entire surgical cases where patients underwent anesthesia, includes a wide range of vital signs variables that are commonly monitored during surgery, and is published in accessible, user-friendly file formats. The text and image file formats let researchers without engineering or computer science backgrounds easily access the data using standard spreadsheet and image browsing software. In future work, monitoring data should be collected from a wider range and larger number of cases, and software tools are needed to support searching and navigating the database.

5 June 2018 in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
Verified
Journal Article
Open access
PDF file
ALAaron Lau
Aaron Lau
NLNasim Lowlaavar
Nasim Lowlaavar
ECErin M. Cooke
Erin M. Cooke
NWNicholas West
Nicholas West
AGAlexandra German
Alexandra German
RMRichard N. Merchant
Richard N. Merchant
The purpose of this study was to evaluate the effects of preoperative forced-air warming on intraoperative hypothermia.

1 January 2011 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
MBMatthias Borowski
Matthias Borowski
Matthias GörgesMatthias Görges
Matthias Görges
RFRoland Fried
Roland Fried
OSOlaf Such
Olaf Such
CWChristian Wrede
Christian Wrede
MIMichael Imhoff
Michael Imhoff
The high number of false positive alarms has long been known to be a serious problem in critical care medicine - yet it remains unresolved. At the same time, threats to patient safety due to missing or suppressed alarms are being reported. The purpose of this paper is to present results from a workshop titled "Too many alarms? Too few alarms?" organized by the Section Patient Monitoring and the Workgroup Alarms of the German Association of Biomedical Engineering of the Association for Electrical, Electronic and Information Technologies. The current situation regarding alarms and their problems in intensive care, such as lack of clinical relevance, alarm fatigue, workload increases due to clinically irrelevant alarms, usability problems in alarm systems, problems with manuals and training, and missing alarms due to operator error are outlined, followed by a discussion of solutions and strategies to improve the current situation. Finally, the need for more research and development, focusing on signal quality considerations, networking of medical devices at the bedside, diagnostic alarms and predictive warnings, usability of alarm systems, education of healthcare providers, creation of annotated clinical databases for testing, standardization efforts, and patient monitoring in the regular ward, are called for.

17 February 2017 in Pediatric Anesthesia
Verified
Journal Article
Closed access
PDF file
Matthias GörgesMatthias Görges
Matthias Görges
GZGuohai Zhou
Guohai Zhou
RBRollin Brant
Rollin Brant
JAJ Mark Ansermino
J Mark Ansermino

1 October 2018 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
NWNicholas West
Nicholas West
KHKlaske van Heusden
Klaske van Heusden
Matthias GörgesMatthias Görges
Matthias Görges
SBSonia Brodie
Sonia Brodie
ARAryannah Rollinson
Aryannah Rollinson
RMRichard N. Merchant
Richard N. Merchant
BACKGROUND: Closed-loop control of anesthesia involves continual adjustment of drug infusion rates according to measured clinical effect. The NeuroSENSE monitor provides an electroencephalographic measure of depth of hypnosis (wavelet-based anesthetic value for central nervous system monitoring [WAVCNS]). It has previously been used as feedback for closed-loop control of propofol, in a system designed using robust control engineering principles, which implements features specifically designed to ensure patient safety. Closed-loop control of a second drug, remifentanil, may be added to improve WAVCNSstability in the presence of variable surgical stimulation. The objective of this study was to design and evaluate the feasibility of a closed-loop system for robust control of propofol and remifentanil infusions using WAVCNSfeedback, with an infusion safety system based on the known pharmacological characteristics of these 2 drugs.METHODS: With Health Canada authorization, research ethics board approval, and informed consent, American Society of Anesthesiologists I–III adults, requiring general anesthesia for elective surgery, were enrolled in a 2-phase study. In both phases, infusion of propofol was controlled in closed loop during induction and maintenance of anesthesia, using WAVCNSfeedback, but bounded by upper- and lower-estimated effect-site concentration limits. In phase I, remifentanil was administered using an adjustable target-controlled infusion and a controller was designed based on the collected data. In phase II, remifentanil was automatically titrated to counteract rapid increases in WAVCNS.RESULTS: Data were analyzed for 127 patients, of median (range) age 64 (22–86) years, undergoing surgical procedures lasting 105 (9–348) minutes, with 52 participating in phase I and 75 in phase II. The overall control performance indicator, global score, was a median (interquartile range) 18.3 (14.2–27.7) in phase I and 14.6 (11.6–20.7) in phase II (median difference, −3.25; 95% confidence interval, −6.35 to −0.52). The WAVCNSwas within ±10 of the setpoint for 84.3% (76.6–90.6) of the maintenance of anesthesia in phase I and 88.2% (83.1–93.4) in phase II (median difference, 3.7; 95% confidence interval, 0.1–6.9). The lower propofol safety bound was activated during 30 of 52 (58%) cases in phase I and 51 of 75 (68%) cases in phase II.CONCLUSIONS: Adding closed-loop control of remifentanil improved overall controller performance. This controller design offers a robust method to optimize the control of 2 drugs using a single sensor. The infusion safety system is an important component of a robust automated anesthesia system, but further research is required to determine the optimal constraints for these safe conditions.