Likarn Wang

Likarn Wang


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2008 in Applied Optics
Verified
Journal Article
Closed access
PDF file
HCHsuan-Jen Chen
Hsuan-Jen Chen
LWLikarn Wang
Likarn Wang
WLW. F. Liu
W. F. Liu
A temperature-insensitive optical fiber tilt sensor is presented. The sensor scheme uses a prestrained fiber Bragg grating to sense the strain, which depends on the tilt angle. To compensate for the temperature effect, materials that have different linear thermal expansion behaviors are used for implementation of the sensor body. The differentiation in the linear thermal expansion would then cause a counter effect to the original temperature effect. Experimental tests show an accuracy of ±0.167° in tilt angle measurement. A temperature stability better than ±0.33° over the temperature range from 27 °C to 75 °C is demonstrated. The resolution 0.0067° in tilt angle measurement is achieved by using our preliminary sensor with a dimension of 16×5×5 cm3.

28 June 2006 in Optics Communications
Verified
Journal Article
Closed access
CCC.L. Chang
C.L. Chang
LWLikarn Wang
Likarn Wang
YCY.J. Chiang
Y.J. Chiang

11 October 2019 in IEEE Sensors Journal
Verified
Journal Article
Open access
HHHsin Hsieh
Hsin Hsieh
KHKai-Shuo Hsu
Kai-Shuo Hsu
TJTai-Lang Jong
Tai-Lang Jong
LWLikarn Wang
Likarn Wang

20 March 2002 in Applied Optics
Verified
Journal Article
Closed access
PDF file
YCYan-Ju Chiang
Yan-Ju Chiang
LWLikarn Wang
Likarn Wang
HCHorng-Shyang Chen
Horng-Shyang Chen
CYChih-Chung (C. C.) Yang
Chih-Chung (C. C.) Yang
WLWen-Fung Liu
Wen-Fung Liu
A temperature-independent fiber-Bragg-grating strain-sensing system, based on a novel optical-power-detection scheme, is developed and analyzed. In this system a pair of fiber Bragg gratings with reflection spectra either partially or substantially overlapping is placed side by side to form a temperature-independent strain-sensor unit. Conventional wavelength-interrogation techniques are not used here, and instead an optical-power-detection scheme is proposed to directly calibrate the measurand, i.e., the strain. Unlike the conventional approach in a multiplexed sensing system, the presented power-detection-based interrogation method does not need the fiber-Bragg-grating sensors to be spectrally separate. The only requirement is that the spectra of the two fiber Bragg gratings of each sensor unit in a multiplexed system be identical or slightly separate (slightly overlapping spectra would also work in the sensing scheme) and the source’s optical power be sufficient for sensitive measurement. Based on a three-sensor-unit system, we demonstrate simple strain measurements of high linearity (±0.4%), good sensitivity [2 microstrains (µS)], high thermal stability (±0.8%), and zero cross talk. The effects of light source spectral flatness and fiber bending loss on measurement accuracy are also discussed.

16 February 2021 in IEEE Sensors Journal
Verified
Journal Article
Open access
YLYuan-Hung Lin
Yuan-Hung Lin
BZBo-Hong Zheng
Bo-Hong Zheng
LWLikarn Wang
Likarn Wang
A new fiber-optic perimeter intrusion detection system employing only one single-mode fiber as a disturbance sensor for each perimeter zone is presented. A disturbance signal generated through interference between lights from two resonators, i.e., a linear laser cavity and an extended resonator, was used for determining intrusion for each defended zone. A single-mode fiber was used not only for sensing the intrusion-induced disturbance but also for transmission of pump and signal lights. Although many papers have reported multi-perimeter-zone intrusion detection systems, the study presents, for the first time, a system with a single-mode fiber used all along the perimeter that is in a line pattern and is sectioned into multiple defended zones. An outdoor test for a four perimeter-zone intrusion detection system was carried out with a short section of fiber attached on a netted fence in each defended zone. Experimental results demonstrated that there was no cross interference between any two defended-zone light circuits, and that a high alarm-upon-intrusion rate and a zero false alarm rate could be reached by using the presented detection algorithm.

15 December 2007 in Optics Communications
Verified
Journal Article
Closed access
CSChin-Feng Su
Chin-Feng Su
LWLikarn Wang
Likarn Wang