The total ionizing radiation (TID) response of commercial NPN silicon germanium hetero-junction bipolar transistors (SiGe HBTs) produced domestically are investigated under dose rates of 800 mGy(Si)/s and 1.3 mGy(Si)/s with a Co-60 gamma irradiation source. The changes of transistor parameters such as Gummel characteristics, and excess base current before and after irradiation, are examined. The results of the experiments show that for the KT1151, the radiation damage is slightly different under the different dose rates after prolonged annealing, and shows a time dependent effect (TDE). For the KT9041, however, the degradations of low dose rate irradiation is higher than for the high dose rate, demonstrating that there is a potential enhanced low dose rate sensitivity (ELDRS) effect for the KT9041. The possible underlying physical mechanisms of the different dose rates responses induced by the gamma rays are discussed.
2 December 2017 in Radiation Effects and Defects in Solids
Enhanced low-dose rate sensitivity (ELDRS) exhibited at low-dose rates (LDRs) by most bipolar devices is considered as one of the main concerns for spacecraft reliability. In this work, a time-saving and conservative approach – temperature-switching approach (TSA) – to simulate the ELDRS of bipolar devices is presented. Good agreement is observed between the predictive curve obtained with the TSA and the LDR data, and TSA provides us with a new insight into the test technique for ELDRS. Additionally, the mechanisms of TSA are analyzed in this paper.
The latent enhanced low dose rate sensitivity (ELDRS) effect is observed in the double-polysilicon self-aligned (DPSA) technology PNP bipolar junction transistor (BJT) irradiated with a high and low dose rate gamma ray, which is discussed from the perspective of the three-stage degradation rate of the excess base current. The great degradation rate as a result of the high dose irradiation of the first stage is dominantly ascribed to the positive oxide trap charges accumulated during a short irradiation, and then due to the competition between the recombination of electrons and capture of the hole by the traps. It declined sharply into a degradation rate saturated region of the second stage. However, for the low dose rate, the small increase in the degradation rate in the first stage is caused by the holes escaping from the initial recombination and being transported to the interface to form the interface states. Then, the competition between the steadily increasing interfacial trap charge and the continuously annealed shallow level oxide trap charge leads to the stable increase of degradation under low dose irradiation. Finally, in stage three, the increases of the degradation rates for high and low dose irradiation result from the different amounts of the hydrogen molecules generated by the hole reactive with depassiviated Si suspended bonds, which can interact with the deep level defects and release protons, causing an increase of interfacial trap charges with prolonged irradiation.
1 September 2021 in Chinese Journal of Electronics
Ionizing radiation effect and failure mechanism of Digital signal processor (DSP) is studied through test-board and automatic test equipment to find the relationship between system function failure and parameter degradation. Static bias is more sensitive than dynamic bias when DSP is tested on-line during radiation. Core current, high-Z leakage current and timing parameter are sensitive to ionizing radiation. No enhanced low-dose-rate sensitivity is found by comparing experiment results under high and low dose rate radiation. External memory interface and Timer are deduced to be the sensitive module by step radiation and analysis basing full parameter test in Verigy 93000. The timing parameter degradation have a strong correlation to these module functions. And the degeneration mechanism is analysed on inverter through Hspice simulation which indicate the leakage circuit caused by radiation can lead a delay to the digital signal propagating. The parasitical capacitance among long connections make it worse to the data transmission around DSP, field programmable gate array and memory. Then an early function failure occurs in test board than Verigy 93000. This work provide support to systematic radiation hardness design and hardness assurance/lot acceptance testing in space applications.