Katarzyna Arkusz

Dr. Katarzyna Arkusz

Department of Biomedical Engineering, University of Zielona Góra, Zielona Góra, Lubuskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2022 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
JMJustyna Mazurek
Justyna Mazurek
ANAdam Nowicki
Adam Nowicki
Katarzyna ArkuszKatarzyna Arkusz
Katarzyna Arkusz
ŁPŁukasz Pałka
Łukasz Pałka
AZAnna Zimoch-Korzycka
Anna Zimoch-Korzycka
KBKatarzyna Baldy-Chudzik
Katarzyna Baldy-Chudzik
Background: Temporary implant-retained restorations are required to support function and esthetics of the masticatory system until the final restoration is completed and delivered. Acrylic resins are commonly used in prosthetic dentistry and lately they have been used in three-dimensional (3D) printing technology. Since this technology it is fairly new, the number of studies on their susceptibility to microbial adhesion is low. Restorations placed even for a short period of time may become the reservoir for microorganisms that may affect the peri-implant tissues and trigger inflammation endangering further procedures. The aim of the study was to test the biofilm formation on acrylamide resins used to fabricate temporary restorations in 3D printing technology and to assess if the post-processing impacts microbial adhesion. Methods: Disk-shaped samples were manufactured using the 3D printing technique from three commercially available UV-curable resins consisting of acrylate and methacrylate oligomers with various time and inhibitors of polymerization (NextDent MFH bleach, NextDent 3D Plus, MazicD Temp). The tested samples were raw, polished and glazed. The ability to create biofilm by oral streptococci (S. mutans, S. sanguinis, S. oralis, S. mitis) was tested, as well as species with higher pathogenic potential: Staphylococcus aureus, Staphylococcus epidermidis and Candida albicans. The roughness of the materials was measured by an atomic force microscope. Biofilm formation was assessed after 72 h of incubation by crystal violet staining with absorbance measurement, quantification of viable microorganisms, and imaging with a scanning electron microscope (SEM). Results: Each tested species formed the biofilm on the samples of all three resins. Post-production processing resulted in reduced roughness parameters and biofilm abundance. Polishing and glazing reduced roughness parameters significantly in the NextDent resin group, while glazing alone caused significant surface smoothing in Mazic Temp. A thin layer of microbial biofilm covered glazed resin surfaces with a small number of microorganisms for all tested strains except S. oralis and S. epidermidis, while raw and polished surfaces were covered with a dense biofilm, rich in microorganisms. Conclusions: UV-curing acrylic resins used for fabricating temporary restorations in the 3D technology are the interim solution, but are susceptible to adhesion and biofilm formation by oral streptococci, staphylococci and Candida. Post-processing and particularly glazing process significantly reduce bacterial biofilm formation and the risk of failure of final restoration.

5 September 2023 in Wear
Verified
Journal Article
Open access
RMRadosław W. Maruda
Radosław W. Maruda
NSNatalia Szczotkarz
Natalia Szczotkarz
MMMariusz Michalski
Mariusz Michalski
Katarzyna ArkuszKatarzyna Arkusz
Katarzyna Arkusz
SWSzymon Wojciechowski
Szymon Wojciechowski
Grzegorz KrolczykGrzegorz Krolczyk
Grzegorz Krolczyk

5 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
MNMarta Nycz
Marta Nycz
Katarzyna ArkuszKatarzyna Arkusz
Katarzyna Arkusz
DPDorota Pijanowska
Dorota Pijanowska
This paper presents the fabrication methodology of an electrochemical biosensor for the detection of heat shock protein 70 (HSP70) as a potential tumor marker with high diagnostic sensitivity. The sensor substrate was a composite based on titanium dioxide nanotubes (TNTs) and silver nanoparticles (AgNPs) produced directly on TNTs by electrodeposition, to which anti-HSP70 antibodies were attached by covalent functionalization. This manuscript contains a detailed description of the production, modification, and the complete characteristics of the material used as a biosensor platform. As-formed TNTs, annealed TNTs, and the final sensor platform—AgNPs/TNTs, were tested using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction analysis (XRD). In addition, open circuit potential (OCP), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV) of these substrates were used to assess the influence of TNTs modification on their electrochemical characteristics. The EIS technique was used to monitor the functionalization steps of the AgNPs/TNTs electrode and the interaction between anti-HSP70 and HSP70. The produced composite was characterized by high purity, and electrical conductivity improved more than twice compared to unmodified TNTs. The linear detection range of HSP70 of the developed biosensor was in the concentration range from 0.1 to 100 ng/mL.

17 January 2023 in Journal of Manufacturing Processes
Verified
Journal Article
Closed access
RMRadosław W. Maruda
Radosław W. Maruda
Katarzyna ArkuszKatarzyna Arkusz
Katarzyna Arkusz
NSNatalia Szczotkarz
Natalia Szczotkarz
SWSzymon Wojciechowski
Szymon Wojciechowski
PNPiotr Niesłony
Piotr Niesłony
GKGrzegorz M. Królczyk
Grzegorz M. Królczyk

25 July 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
MNMarta Nycz
Marta Nycz
Katarzyna ArkuszKatarzyna Arkusz
Katarzyna Arkusz
DPDorota Pijanowska
Dorota Pijanowska
This paper presents the comparison of the effects of three methods of production of silver spherical and near-spherical nanoparticles (AgNPs) on the titanium dioxide nanotubes (TNT) base: cyclic voltammetry, chronoamperometry, and sputter deposition. It also evaluates the influence of silver nanoparticles on the electrochemical properties of the developed electrodes. The novelty of this research was to fabricate regular AgNPs free of agglomerates uniformly distributed onto the TNT layer, which has not been accomplished with previous attempts. The applied methods do not require stabilizing and reducing reagents. The extensive electrochemical characteristic of AgNP/TNT was performed by open circuit potential and electrochemical impedance spectroscopy methods. For AgNPs/TNT obtained by each method, the impedance module of these electrodes was up to 50% lower when compared to TNT, which means that AgNPs enabled more efficient electron transfer due to the effective area increase. In addition, the presence of nanoparticles increases the corrosion resistance of the prepared electrodes. These substrates can be used as electrochemical sensors due to their high electrical conductivity, and also as implants due to the antibacterial properties of both the TNT and AgNPs.

9 September 2020 in Urolithiasis
Verified
Journal Article
Open access
PDF file
Katarzyna ArkuszKatarzyna Arkusz
Katarzyna Arkusz
KPKamila Pasik
Kamila Pasik
AHAndrzej Halinski
Andrzej Halinski
AHAdam Halinski
Adam Halinski
The aim of this work was to determine which part of a double-J ureteral stent (DJ stents) showed the highest tendency to crystal, calculi, and biofilm deposition after ureterorenoscopic-lithotripsy procedure (URS-L) to treat calcium oxalate stones. Additionally, the mechanical strength and the stiffness of DJ stents were evaluated before and after exposure to urine. Obtained results indicated that the proximal (renal pelvis) and distal (urinary bladder) part is the most susceptible for post-URS-L fragments and urea salt deposition. Both, the outer and inner surfaces of the DJ ureteral stents were completely covered even after 7 days of implantation. Encrustation of DJ stents during a 31-day period results in reducing the Young’s modulus by 27–30%, which confirms the loss of DJ stent elasticity and increased probability of cracks or interruption. Performed analysis pointed to the need to use an antibacterial coating in the above-mentioned part of the ureteral stent to prolong its usage time and to prevent urinary tract infection.