There is increasing interest in miniaturized technologies in diagnostics, therapeutic testing, and biomedicinal fundamental research. The same is true for the dermal studies in topical drug development, dermatological disease pathology testing, and cosmetic science. This review aims to collect the recent scientific literature and knowledge about the application of skin-on-a-chip technology in drug diffusion studies, in pharmacological and toxicological experiments, in wound healing, and in fields of cosmetic science (ageing or repair). The basic mathematical models are also presented in the article to predict physical phenomena, such as fluid movement, drug diffusion, and heat transfer taking place across the dermal layers in the chip using Computational Fluid Dynamics techniques. Soon, it can be envisioned that animal studies might be at least in part replaced with skin-on-a-chip technology leading to more reliable results close to study on humans. The new technology is a cost-effective alternative to traditional methods used in research institutes, university labs, and industry. With this article, the authors would like to call attention to a new investigational family of platforms to refresh the researchers’ theranostics and preclinical, experimental toolbox.
Carbon nanotubes (CNTs) – perhaps the most enticing class of nano-materials, can be added in small volume fractions to enhance the thermal properties of fluids when process intensification or even device miniaturization is required. This work reports on the results obtained when measuring viscosity, and thermal conductivity of homogenous CNTs – water based nanofluids. The influence of CNTs volume concentration on the nanofluid thermo-physical properties is studied and measurements are undertaken at different temperatures, ranging from 283.15 K to 333.15 K. The nanofluids have been prepared by adding different volume concentrations of treated CNTs to water. The latter has been then sonicated for one hour and the colloidal stability monitored via UV – vis spectrophotometer. The absorbance of the nanofluid was observed at 263 nm, and the average concentration of CNTs was maintained at 9.35 mg/l, even after 200 hours, over 97% when compared with the initial concentration. The viscosity was measured using a controlled stress rheometer, and the measurements were performed in the shear rate ranging from 0 to 600 sec-1. At the same shear rate and temperature, the viscosity was observed to rise with increasing CNTs volume concentration. In what concerns thermal conductivity, it was assessed with a KD2 pro thermal property tester from Decagon Devices and the results clearly show that thermal conductivity rises with CNTs volume fraction, reaching its maximum at 2.5%vol where it represents more than 100% enhancement when the comparison is established with the corresponding value for the base fluid, at the same temperature conditions (i.e. 283.15 – 303.15 K). Furthermore, at higher temperatures (i.e. 313.15 – 333.15 K), the latter, for up to 1%vol concentration represents a 70% enhancement in thermal conductivity.
A fabrication method is developed to produce a microfluidic device to test cell adhesion to polymeric materials. The process is able to produce channels with walls of any spin coatable polymer. The method is a modification of the existing poly-dimethylsiloxane soft lithography method and, therefore, it is compatible with sealing methods and equipment of most microfluidic laboratories. The molds are produced by xurography, simplifying the fabrication in laboratories without sophisticated equipment for photolithography. The fabrication method is tested by determining the effective differences in bacterial adhesion in five different materials. These materials have different surface hydrophobicities and charges. The major drawback of the method is the location of the region of interest in a lowered surface. It is demonstrated by bacterial adhesion experiments that this drawback has a negligible effect on adhesion. The flow in the device was characterized by computational fluid dynamics and it was shown that shear stress in the region of interest can be calculated by numerical methods and by an analytical equation for rectangular channels. The device is therefore validated for adhesion tests.