A three-dimensional finite element model of a 500 kV high-voltage transmission tower-line coupling system is built using ANSYS software and verified with field-measured data. The dynamic responses of the tower-line system under different wind speeds and directions are analyzed and compared with the design code. The results indicate that wind speed plays an important role in the tower-line coupling effect. Under the low wind speed, the coupling effect is less obvious and can be neglected. With increased wind speed, the coupling effect on the responses of the tower gradually becomes prominent, possibly resulting in the risk of premature failure of the tower-line system. The designs based on the quasi-static method stipulated in the current design code are unsafe because of the ignorance of the adverse impacts of coupling vibration on the transmission towers. In practical engineering, when the quasi-static method is still used in design, the results for the design wind speed should be multiplied by the corresponding tower-line coupling effect amplifying coefficient .
A model of the flow-vibration-electrical circuit multiphysical coupling system for solving square column vortex-induced vibration piezoelectric energy harvesting (VIVPEH) is proposed in this paper. The quasi steady state theory is adopted to describe the fluid solid coupling process of vortex-induced vibration based on the finite volume method coupled Gauss equation. The vibrational response and the quasi steady state form of the output voltage are solved by means of the matrix coefficient method and interactive computing. The results show that attack angles play an important role in the performance of square column VIVPEH, of which ° is a relatively ideal attack angle of square column VIVPEH.
A numerical simulation of the hysteresis performance of corroded reinforced concrete (RC) frame columns was conducted. Moreover, the results obtained were compared with experimental data. On this basis, a degenerated three-linearity (D-TRI) restoring force model was established which could reflect the hysteresis performance of corroded RC frame columns through theoretical analysis and data fitting. Results indicated that the hysteretic bearing capacity of frame columns decreased significantly due to corrosion of the rebar. In view of the characteristics of the hysteresis curve, the plumpness of the hysteresis loop for frame columns decreased and shrinkage increased with increasing rebar corrosion. All these illustrated that the seismic energy dissipation performance of frame columns reduced but their brittleness increased. As for the features of the skeleton curve, the trends for corroded and noncorroded members were basically consistent and roughly corresponded to the features of a trilinear equivalent model. Thereby, the existing Clough hysteresis rule can be used to establish the restoring force model applicable to corroded RC frame columns based on that of the noncorroded RC members. The calculated skeleton curve and hysteresis curve of corroded RC frame columns using the D-TRI model are closer to the experimental results.
Small‐scale energy harvesting from ambient vibration induced by aerodynamic instabilities can be used for wireless sensing applications. The configuration with a bluff body attached to a piezoelectric cantilever has been exploited in many studies. For low‐wind energy harvesting, vortex‐induced vibration is investigated more frequently than other types of flow‐induced motions, such as galloping and flutter, because of its quasisteady behavior called the potential lock‐in phenomenon. In practice, a stationary square column is placed before the energy harvester to generate wake shedding, which can broaden the bandwidth of the energy harvester compared with a pure energy harvester equipped with a single bluff body. This paper presents a proposed CFD method coupled with an electromechanical model to predict the performance of the energy harvester. The proposed approach is verified with our experimental setup. The time history of the voltage output and the frequency response is obtained by performing the relevant experiments. A subsequent CFD study is performed to investigate the flow patterns of the present energy harvesting system.
Taking an actual 3MW steel–concrete composite wind turbine tower as an example, a finite element model of the tower structure was established, and static bearing capacity and dynamic time history response analyses were performed to identify the locations where the structure is prone to failure. On this basis, the fatigue lives of the turbine tower at the most unfavorable locations were predicted using linear cumulative damage theory, and the fatigue reliability at the corresponding locations of the structure was calculated using the kriging–subset simulation method. The most dangerous locations of the tower that are most prone to failure are as follows: the bottom of the leeward side of the upper steel tube, the flange of the steel tube, the bolt-hole imprinting surface of the flange, the leeward side of the transition tube, and the top of the leeward side of the concrete tube. The failure risk of the flange and bolt-hole imprinting surface of the upper steel tube is relatively high, followed by that of the transition tube. This indicates that special attention should be given to the design and daily maintenance of this part. The fatigue resistance of the tower can be enhanced by improving the strength of the flange plate or increasing the number of bolts and strengthening the transition tube.