17 December 2019 in Environmental Health and Preventive Medicine
Verified
Journal Article
Open access
PDF file
YNYoshitake Nakayama
Yoshitake Nakayama
Hiroko NakaokaHiroko Nakaoka
Hiroko Nakaoka
Norimichi SuzukiNorimichi Suzuki
Norimichi Suzuki
KTKayo Tsumura
Kayo Tsumura
Masamichi HanazatoMasamichi Hanazato
Masamichi Hanazato
CMChisato Mori
Chisato Mori
Background: With the aim to prevent sick building syndrome and worsening of allergic symptoms, primarily resulting from the indoor environment, the relationships among people’s residential environment in recent years, their lifestyle habits, their awareness, and their symptoms were investigated using an online survey. Methods: In the survey, respondents experiencing symptoms specific to sick building syndrome, although they were not diagnosed with sick building syndrome, were categorized in the pre-sick building syndrome group. The relationships among individual characteristics, residential environment, and individual awareness were analyzed. Results: Results showed that the prevalence of pre-sick building syndrome was high among young (aged 20–29 years) population of both sexes. In addition, “condensation,” “moisture,” “musty odors” in the house, and the “use of deodorant and fragrance” were all significantly associated with pre-sick building syndrome. Conversely, there was no significant association with recently built “wooden” houses that are highly airtight and have thermal insulation. Conclusions: Efficient “ventilation” plans and “ventilation” improvement and air conditioning systems to prevent mold and condensation in rooms are necessary to maintain a good, indoor environment that is beneficial for health. Efforts should also be made to encourage individuals to regularly clean and effectively ventilate their homes.

1 January 2021 in Science of The Total Environment
Verified
Journal Article
Open access
Norimichi SuzukiNorimichi Suzuki
Norimichi Suzuki
Hiroko NakaokaHiroko Nakaoka
Hiroko Nakaoka
YNYoshitake Nakayama
Yoshitake Nakayama
KTKayo Tsumura
Kayo Tsumura
KTKohki Takaguchi
Kohki Takaguchi
CMChisato Mori
Chisato Mori
It is well known that the indoor environment, particularly indoor air quality (IAQ), has significant effects on building-related symptoms (BRSs) in humans, such as irritation of mucosal membranes, headaches, and allergies, such as asthma and atopic dermatitis. In 2017, Chiba University launched the "Chemiless Town Project Phase 3" to investigate the relationship between IAQ and human health. Two laboratory houses (LHs) were built on a university campus in which the interiors and exteriors were similar, but the levels of indoor air volatile organic compounds (VOCs) were different. A total of 141 participants evaluated IAQ using their sensory perception. There was a significant relationship between differences in VOC levels and BRSs occurrence (OR: 6.89, 95% CI: 1.40-33.98). It was suggested that people with a medical history of allergies (OR: 5.73, 95% CI: 1.12-29.32) and those with a high sensitivity to chemicals (OR: 8.82, 95% CI: 1.16-67.16) tended to experience BRSs. Thus, when buildings are constructed, people with a history of allergies or with a sensitivity to chemicals may be at high risk to BRSs, and it is important to pay attention to IAQ to prevent BRSs.

Norimichi SuzukiNorimichi Suzuki
Norimichi Suzuki
Hiroko NakaokaHiroko Nakaoka
Hiroko Nakaoka
Masamichi HanazatoMasamichi Hanazato
Masamichi Hanazato
YNYoshitake Nakayama
Yoshitake Nakayama
KTKayo Tsumura
Kayo Tsumura
CMChisato Mori
Chisato Mori
Recently, people have become increasingly aware of potential health issues related to indoor environments. In this study, we measure the concentrations of various volatile organic compounds, carbonyl compounds, and semi-volatile organic compounds, as well as the ventilation rates, in 49 new houses with light-gauge steel structures one week after completion. The proper indoor air quality of new residential environments can be ensured by characterizing people’s exposure to certain chemicals and assessing future risks. Our results show that the concentrations of the measured compounds were lower than the guideline values set by the Ministry of Health, Labour and Welfare of Japan, and would continue to decrease. However, we observed that unregulated compounds, assumed to be substitutes for regulated solvents, contributed substantially to the total volatile organic compounds. To reduce indoor chemical exposure risks, the concentrations of these unregulated compounds should also be minimized. In addition, their sources need to be identified, and manufacture and use must be monitored. We believe it is important to select low-emission building materials for reducing residents’ exposure to indoor chemicals.

Norimichi SuzukiNorimichi Suzuki
Norimichi Suzuki
Hiroko NakaokaHiroko Nakaoka
Hiroko Nakaoka
AEAkifumi Eguchi
Akifumi Eguchi
Masamichi HanazatoMasamichi Hanazato
Masamichi Hanazato
YNYoshitake Nakayama
Yoshitake Nakayama
CMChisato Mori
Chisato Mori
Herein, the concentrations of formic acid, acetic acid, and ammonia in samples of indoor air for 47 new houses were measured two weeks after completion. The houses were fabricated with light-gauge steel structures. The measurements were performed in living rooms and bedrooms without furniture and outdoors. Air samples were analyzed using ion chromatography. The mean values were 28 (living room), 30 (bedroom), and 20 μg m−3 (outdoor air) for formic acid; 166 (living room), 151 (bedroom), and 51 μg m−3 (outdoor air) for acetic acid; and 73 (living room), 76 (bedroom), and 21 μg m−3 (outdoor air) for ammonia. The total values of the three substances accounted for 39.4–40.7% of the sum of chemical compound values. The analyzed compounds were indicated by two principal components (PC), PC1 (30.1%) and PC2 (9%), with 39.1% total variance. Formic acid, acetic acid, and ammonia were positively aligned with PC1 and negatively aligned with PC2. Factors such as room temperature, aldehydes, and phthalates were positively aligned with PC1 and negatively aligned with PC2. Furthermore, concentrations of formic acid, acetic acid, and ammonia were significantly and positively correlated with room temperature (p < 0.05).

YNYoshitake Nakayama
Yoshitake Nakayama
Norimichi SuzukiNorimichi Suzuki
Norimichi Suzuki
Hiroko NakaokaHiroko Nakaoka
Hiroko Nakaoka
KTKayo Tsumura
Kayo Tsumura
KTKohki Takaguchi
Kohki Takaguchi
CMChisato Mori
Chisato Mori
The relationship between chemical concentrations in indoor air and the human sense of comfort and relaxation have been reported. We investigated the effect of the sum of volatile organic compounds (ΣVOCs; sum of 79 VOCs) on the level of relaxation in two laboratory houses with almost identical interior and exterior appearances. The electroencephalogram (EEG) was monitored to evaluate the degree of personal relaxation objectively. The experiments were conducted in laboratory houses (LH) A and B with lower and higher levels of ΣVOCs, respectively. A total of 168 healthy volunteers participated, who each performed the task for 20 min, followed by a 10-min break, and EEG was measured during the break. Simultaneously as subjective evaluations, the participants were asked to fill a questionnaire regarding the intensity of odor and preference for the air quality in each LH. The subjective evaluation showed a significant association between ΣVOCs and participants’ relaxation (OR: 2.86, 95%CI: 1.24–6.61), and the objective evaluation indicated that the participants were more relaxed in the LH with lower levels of ΣVOCs than that with higher levels (OR: 3.03, 95%CI: 1.23–7.50). Therefore, the reduction of ΣVOCs and odors in indoor air would have an effect, which is the promotion of relaxation.