2 April 2004 in Building and Environment
Verified
Journal Article
Closed access
CCCheng Li Cheng
Cheng Li Cheng
YHY.T. Hong
Y.T. Hong

1 June 2016 in Water
Verified
Journal Article
Open access
PDF file
CCCheng Li Cheng
Cheng Li Cheng
JPJr-Jie Peng
Jr-Jie Peng
MHMing-Chin Ho
Ming-Chin Ho
WLWan-Ju Liao
Wan-Ju Liao
SCSzu-Jen Chern
Szu-Jen Chern
Low carbon policies, including those aimed at increasing water efficiency, have been adopted as a crucial strategy for combating global warming and climate change. The green building evaluation system used in Taiwan was first applied in 1999 and initially utilized a building’s water efficiency as the threshold index for determining the building’s environmental impact. Since 1999, more than a thousand buildings have been certified as green buildings using this evaluation system. The quantitative effects of water conservation efforts should be provided to policy makers as a form of positive feedback. To that end, the present study offers a calculation process for estimating the quantitative volume of water saved by practical green buildings. The baseline water usage for all kinds of buildings was determined to serve as the criterion for determining the water-saving efficiency of individual buildings. An investigation of the average water-saving rate from 2000 to 2013 for 1320 buildings certified as green buildings was also conducted to validate the estimation results and found that these green buildings saved an average of approximately 37.6% compared to the baseline water usage rate for all buildings. Water savings will inevitably follow from the use of water-saving appliances or water-saving designs for buildings. The proposed calculation process can be used to clarify the relationships between specific water-saving concepts and the real water usage efficiency of green buildings.

31 January 2007 in Building and Environment
Verified
Journal Article
Closed access
CCCheng Li Cheng
Cheng Li Cheng
CCC.P. Chou
C.P. Chou
CCC.Y. Chan
C.Y. Chan

1 March 2005 in Journal of the Chinese Institute of Engineers
Verified
Journal Article
Closed access
CCCheng Li Cheng
Cheng Li Cheng
WLWen‐Hung Lu
Wen‐Hung Lu
MSMing‐Der Shen
Ming‐Der Shen
Pressure fluctuation control in vertical drainage stacks has been identified as important to insure sanitary drainage performance in early empirical studies. Chaotic plumbing and over‐design are common in utility services within building envelopes from domestic investigations in Taiwan. Considerable progress has been made in predicting the air pressure distribution within vertical drainage stacks. Following previous research, this paper focuses on an empirical approach to air pressure prediction in vertical drainage stacks. An experimental device that simulates a medium high apartment was set up to provide empirical parameters and model verification. Comparisons between the measured data and calculated values reveal that this prediction model can reproduce the mean air pressure distribution value in a vertical drainage stack given single point discharge and steady flow conditions.

CCCheng Li Cheng
Cheng Li Cheng
YLYen-Yu Lin
Yen-Yu Lin
Being aware of global pandemics, this research focused on the potential infection routes in building drainage systems. Case studies have found that dysfunctional building drainage systems not only failed to block contaminants but also potentially became a route for the spreading of viruses. Several fluid simulations in pipelines were conducted in this research using COMSOL Multiphysics. In particular, virus transmission from one patient’s room to other uninfected residential units through pipelines was visualized. A 12-story building, which is commonly seen in the local area, was designed as a simulation model to visualize the transmission and analyze its hazards. Furthermore, five environmental factors were filtered out for discussion: distance, time span, pressure, initial concentration, and environment temperature. By manipulating these factors, the relationship between the factors and the behavior of the contaminant could be explored. In addition, a simulation with a different pipeline arrangement was included to observe the virus diffusion behavior under different scenarios. The visualized simulation concluded that the contaminant would spread through the drainage system and arrive at the neighboring four floors within an hour under the circumstances of a 12-story building with broken seals and constant pressure and contaminant supply on the seventh floor. Meanwhile, the whole building would be exposed to infection risks by the continuous virus spreading through a drainage system. Distance, time span, and pressure were considered critical factors that affected indoor contamination in the system. On the other hand, initial concentration and environmental temperature did not have significant roles. Visualizing the behavior of viruses provides a glimpse of what happens behind walls, paving the way for recognizing the importance of maintaining functional drainage systems for individuals’ health.

Ling Tim WongLing Tim Wong
Ling Tim Wong
Kwok-wai MUIKwok-wai MUI
Kwok-wai MUI
CCCheng Li Cheng
Cheng Li Cheng
PLPolly Leung
Polly Leung
Time-variant positive air pressure in a drainage stack poses a risk of pathogenic virus transmission into a habitable space, however, the excessive risk and its significance have not yet been sufficiently addressed for drainage system designs. This study proposes a novel measure for the probable pathogenic virus transmission risk of a high-rise drainage stack with the occurrence of positive air pressure. The proposed approach is based on time-variant positive air pressures measured in a 38 m high drainage stack of a full-scale experimental tower under steady flow conditions of flow rate 1–4 Ls−1 discharging at a height between 15 m to 33 m above the stack base. The maximum pressure and probabilistic positive air pressures in the discharging stack ventilation section with no water (Zone A of the discharging drainage stack) were determined. It was demonstrated that the positive air pressures were lower in frequency as compared with those in other stack zones and could propagate along the upper 1/3 portion of the ventilation pipe (H’ ≥ 0.63) towards the ventilation opening at the rooftop. As the probabilistic positive pressures at a stack height were found to be related to the water discharging height and flow rate, a risk model of positive air pressure is proposed. Taking the 119th, 124th, 140th and 11,547th COVID-19 cases of an epidemiological investigation in Hong Kong as a baseline of concern, excessive risk of system overuse was evaluated. The results showed that for a 20–80% increase in the frequency of discharge flow rate, the number of floors identified at risk increased from 1 to 9 and 1 to 6 in the 34- and 25-storey residential buildings, respectively. The outcome can apply to facilities planning for self-quarantine arrangements in high-rise buildings where pathogenic virus transmission associated with drainage system overuse is a concern.