AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory (PhotoBIO-OIL), National Institute of Advanced Industrial Science and Technology (AIST)
+2
Prof. Shin-ichi Wakida
AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory (PhotoBIO-OIL), National Institute of Advanced Industrial Science and Technology (AIST)
In this Letter, we describe an accurate antibody detection method using a fabricated extended-gate type organic field-effect-transistor (OFET), which can be operated at below 3 V. The protein-sensing portion of the designed device is the gate electrode functionalized with streptavidin. Streptavidin possesses high molecular recognition ability for biotin, which specifically allows for the detection of biotinylated proteins. Here, we attempted to detect biotinylated immunoglobulin G (IgG) and observed a shift of threshold voltage of the OFET upon the addition of the antibody in an aqueous solution with a competing bovine serum albumin interferent. The detection limit for the biotinylated IgG was 8 nM, which indicates the potential utility of the designed device in healthcare applications.
We investigate electromagnetic coupling between plasmonic and molecular electronic resonances using single-molecular surface-enhanced resonance Raman scattering (SERRS) from single silver nanoparticle dimers. When dimers exhibit SERRS activity, their elastic light scattering spectra show two lines, which are temporally closing toward each other. The higher energy line eventually disappears at the time of SERRS quenching. A coupled-oscillator model composed of plasmonic and molecular electronic resonances consistently reproduces the above interesting results by decreasing coupling energy, indicating that SERRS can be a quantitative probe for strong coupling between the two resonances.
A novel biosensor for immunoglobulin G (IgG) detection based on an extended-gate type organic field effect transistor (OFET) has been developed that possesses an anti-IgG antibody on its extended-gate electrode and can be operated below 3 V. The titration results from the target IgG in the presence of a bovine serum albumin interferent, clearly exhibiting a negative shift in the OFET transfer curve with increasing IgG concentration. This is presumed to be due an interaction between target IgG and the immobilized anti-IgG antibody on the extended-gate electrode. As a result, a linear range from 0 to 10 µg/mL was achieved with a relatively low detection limit of 0.62 µg/mL (=4 nM). We believe that these results open up opportunities for applying extended-gate-type OFETs to immunosensing.