The incidence of gambiense human African trypanosomiasis (gHAT) in Uganda has been declining, from 198 cases in 2008, to only 20 in 2012. Interruption of transmission of the disease by early diagnosis and treatment is core to the control and eventual elimination of gHAT. Until recently, the format of available screening tests had restricted screening and diagnosis to central health facilities (passive screening). We describe a novel strategy that is contributing to elimination of gHAT in Uganda through expansion of passive screening to the entire population at risk. In this strategy, patients who are clinically suspected of having gHAT at primary health facilities are screened using a rapid diagnostic test (RDT), followed by parasitological confirmation at strategically located microscopy centres. For patients who are positive with the RDT and negative by microscopy, blood samples undergo further testing using loop-mediated isothermal amplification (LAMP), a molecular test that detects parasite DNA. LAMP positive patients are considered strong suspects, and are re-evaluated by microscopy. Location and upgrading of facilities to perform microscopy and LAMP was informed by results of georeferencing and characterization of all public healthcare facilities in the 7 gHAT endemic districts in Uganda. Three facilities were upgraded to perform RDTs, microscopy and LAMP, 9 to perform RDTs and microscopy, and 200 to screen patients with RDTs. This reduced the distance that a sick person must travel to be screened for gHAT to a median distance of 2.5km compared to 23km previously. In this strategy, 9 gHAT cases were diagnosed in 2014, and 4 in 2015. This enhanced passive screening strategy for gHAT has enabled full coverage of the population at risk, and is being replicated in other gHAT endemic countries. The improvement in case detection is making elimination of the disease in Uganda an imminent possibility.
12 November 2020 in PLOS Neglected Tropical Diseases
Loop-mediated isothermal amplification allows the rapid, sensitive and specific amplification of DNA without complex and expensive equipment. We compared the diagnostic performance of Loopamp™ Leishmania Detection Kit (Eiken Chemical Co., Ltd., Tokyo, Japan) with conventional and real-time polymerase chain reaction (PCR) for human cutaneous and visceral leishmaniasis caused by L. infantum. A total of 230 DNA samples from cutaneous (CL) and visceral (VL) leishmaniasis cases and controls from Spain, characterized by Leishmania nested PCR (LnPCR) were tested by: (i) the Loopamp™ Leishmania Detection Kit (Loopamp), run on Genie III real-time fluorimeter (OptiGene, UK); and (ii) real-time quantitative PCR (qPCR). The Loopamp test returned 98.8% (95% confidence interval—CI: 96.0–100.00) sensitivity and specificity of 97.7% (95% CI: 92.2–100) on VL samples, and 100% (95% CI: 99.1–100) sensitivity and 100.0% (95% CI: 98.8–100.0) specificity on CL samples. The Loopamp time-to-positivity (Tp) obtained by real-time fluorimetry showed excellent concordance (C = 97.91%) and strong correlation (r = 0.799) with qPCR’s cycle threshold (Ct). The performance of Loopamp is comparable to that of LnPCR and qPCR in the diagnosis of cutaneous and visceral leishmaniasis due to L. infantum. The excellent correlation between the Tp and Ct should be further investigated to determine the accuracy of Loopamp to quantify parasite load in tissues.
Serological tests for gambiense human African trypanosomiasis (gHAT) detect antibodies to antigens on the cell surface of bloodstream trypanosomes. As trypanosomes that cause animal African trypanosomiasis (AAT) also express related antigens, we have evaluated two rapid diagnostic tests (RDTs) on cattle in trypanosomiasis endemic and non-endemic regions, to determine whether gHAT serological tests could also be used to screen for AAT. Two RDTs, 1G RDT, made with native antigens, and p2G RDT, made with recombinant antigens, were tested on 121 cattle in a trypanosomiasis-free region, and on 312 cattle from a rhodesiense HAT and AAT endemic region. A subset of samples from the endemic region were also tested with two immune trypanolysis (TL) tests. The sensitivity of the tests was estimated by evaluating the result of the RDT on samples that were positive by both microscopy and internal transcribed spacer (ITS) PCR, whilst specificity was the result of the RDT on samples that were negative by ITS PCR and microscopy, and others from the non-endemic region. The specificity of the p2G RDT on cattle from the non-endemic region was 97.5% (95% CI: 93.0–99.2%), compared to only 57.9% (95% CI: 48.9–66.3%) for 1G RDT. The specificities of 1G RDT, p2G RDT and TL on endemic control cattle were 14.6% (95% CI: 9.7–21.5%), 22.6% (95% CI: 16.4–30.3%) and 68.3% (95% CI: 59.6–75.9%), respectively. The sensitivities of the tests on trypanosome positive samples were 85.1% (95% CI: 79.1–89.7%), 89.1% (95% CI: 83.7–93.0%) and 59.3% (95% CI: 51.8–66.4%), respectively. Among the same samples, 51.7% were positive by both TL and the 1G RDT. These serological tests detect cross-reacting antibodies in cattle. The p2G RDT based on recombinant antigens had a high specificity in a non-endemic region, while the 1G RDT had a lower specificity, suggesting cross-reactivity with other pathogens.