26 April 2019 in Materials
Verified
Journal Article
Open access
PDF file
TBTheresa Brueckner
Theresa Brueckner
PHPhilipp Heilig
Philipp Heilig
MJMartin Cornelius Jordan
Martin Cornelius Jordan
Mila M. PaulMila M. Paul
Mila M. Paul
TBTorsten Blunk
Torsten Blunk
SHStefanie Hoelscher-Doht
Stefanie Hoelscher-Doht
(1) Background: Bone substitutes are essential in orthopaedic surgery to fill up large bone defects. Thus, the aim of the study was to compare diverse bone fillers biomechanically to each other in a clinical-relevant test set-up and to detect differences in stability and handling for clinical use. (2) Methods: This study combined compressive strength tests and screw pullout-tests with dynamic tests of bone substitutes in a clinical-relevant biomechanical fracture model. Beyond well-established bone fillers (ChronOSTM Inject and Graftys® Quickset), two newly designed bone substitutes, a magnesium phosphate cement (MPC) and a drillable hydrogel reinforced calcium phosphate cement (CPC), were investigated. (3) Results: The drillable CPC revealed a comparable displacement of the fracture and maximum load to its commercial counterpart (Graftys® Quickset) in the clinically relevant biomechanical model, even though compressive strength and screw pullout force were higher using Graftys®. (4) Conclusions: The in-house-prepared cement allowed unproblematic drilling after replenishment without a negative influence on the stability. A new, promising bone substitute is the MPC, which showed the best overall results of all four cement types in the pure material tests (highest compressive strength and screw pullout force) as well as in the clinically relevant fracture model (lowest displacement and highest maximum load). The low viscosity enabled a very effective interdigitation to the spongiosa and a complete filling up of the defect, resulting in this demonstrated high stability. In conclusion, the two in-house-developed bone fillers revealed overall good results and are budding new developments for clinical use.

12 April 2021 in Materials
Verified
Journal Article
Open access
PDF file
PHPhilipp Heilig
Philipp Heilig
PSPhoebe Sandner
Phoebe Sandner
MJMartin Cornelius Jordan
Martin Cornelius Jordan
RJRafael Gregor Jakubietz
Rafael Gregor Jakubietz
RMRainer Heribert Meffert
Rainer Heribert Meffert
SHStefanie Hoelscher-Doht
Stefanie Hoelscher-Doht
Clinically used mineral bone cements lack high strength values, absorbability and drillability. Therefore, magnesium phosphate cements have recently received increasing attention as they unify a high mechanical performance with presumed degradation in vivo. To obtain a drillable cement formulation, farringtonite (Mg3(PO4)2) and magnesium oxide (MgO) were modified with the setting retardant phytic acid (C6H18O24P6). In a pre-testing series, 13 different compositions of magnesium phosphate cements were analyzed concentrating on the clinical demands for application. Of these 13 composites, two cement formulations with different phytic acid content (22.5 wt% and 25 wt%) were identified to meet clinical demands. Both formulations were evaluated in terms of setting time, injectability, compressive strength, screw pullout tests and biomechanical tests in a clinically relevant fracture model. The cements were used as bone filler of a metaphyseal bone defect alone, and in combination with screws drilled through the cement. Both formulations achieved a setting time of 5 min 30 s and an injectability of 100%. Compressive strength was shown to be ~12–13 MPa and the overall displacement of the reduced fracture was <2 mm with and without screws. Maximum load until reduced fracture failure was ~2600 N for the cements only and ~3800 N for the combination with screws. Two new compositions of magnesium phosphate cements revealed high strength in clinically relevant biomechanical test set-ups and add clinically desired characteristics to its strength such as injectability and drillability.

21 January 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
PHPhilipp Heilig
Philipp Heilig
MJMartin Cornelius Jordan
Martin Cornelius Jordan
MPMila Marie Paul
Mila Marie Paul
EKEva Kupczyk
Eva Kupczyk
RMRainer Heribert Meffert
Rainer Heribert Meffert
SHStefanie Hoelscher-Doht
Stefanie Hoelscher-Doht

22 December 2022 in Communications Medicine
Verified
Journal Article
Open access
PDF file
MJMartin C. Jordan
Martin C. Jordan
DBDavid Bröer
David Bröer
CFChristian Fischer
Christian Fischer
PHPhilipp Heilig
Philipp Heilig
FGFabian Gilbert
Fabian Gilbert
RMRainer H. Meffert
Rainer H. Meffert
Background: Traumatic separation of the pubic symphysis can destabilize the pelvis and require surgical fixation to reduce symphyseal gapping. The traditional approach involves open reduction and the implantation of a steel symphyseal plate (SP) on the pubic bone to hold the reposition. Despite its widespread use, SP-fixation is often associated with implant failure caused by screw loosening or breakage. Methods: To address the need for a more reliable surgical intervention, we developed and tested two titanium cable-clamp implants. The cable served as tensioning device while the clamp secured the cable to the bone. The first implant design included a steel cable anterior to the pubic symphysis to simplify its placement outside the pelvis, and the second design included a cable encircling the pubic symphysis to stabilize the anterior pelvic ring. Using highly reproducible synthetic bone models and a limited number of cadaver specimens, we performed a comprehensive biomechanical study of implant stability and evaluated surgical feasibility. Results: We were able to demonstrate that the cable-clamp implants provide stability equivalent to that of a traditional SP-fixation but without the same risks of implant failure. We also provide detailed ex vivo evaluations of the safety and feasibility of a trans-obturator surgical approach required for those kind of fixation. Conclusion: We propose that the developed cable-clamp fixation devices may be of clinical value in treating pubic symphysis separation.

30 August 2023 in Clinical Biomechanics
Verified
Journal Article
Closed access
SHStefanie Hoelscher-Doht
Stefanie Hoelscher-Doht
MHMaximilian Heilig
Maximilian Heilig
SHSebastian Philipp von Hertzberg-Boelch
Sebastian Philipp von Hertzberg-Boelch
MJMartin Cornelius Jordan
Martin Cornelius Jordan
UGUwe Gbureck
Uwe Gbureck
PHPhilipp Heilig
Philipp Heilig

7 August 2024 in European Journal of Trauma and Emergency Surgery
Verified
Journal Article
Open access
PDF file
MJMartin C. Jordan
Martin C. Jordan
RWRichard Wagner
Richard Wagner
LHLukas Hufnagel
Lukas Hufnagel
JBJustus Bremer
Justus Bremer
MHMaximilian Heilig
Maximilian Heilig
RMRainer H. Meffert
Rainer H. Meffert
Purpose: The role of transobturator-cable-fixation (TOCF) in traumatic symphyseal rupture of the pelvic ring remains unclear. This case series aims to evaluate TOCF in complex and revision cases in pelvic surgery. Methods: A retrospective analysis of a chronological case series was conducted, studying pelvic fractures stabilized using TOCF between January 2006 and December 2022. The variables considered included age, gender, fracture classification, Injury Severity Score (ISS), Body Mass Index (BMI), trauma mechanism, time to surgery, fixation technique, hospital duration, complications, status on discharge (Glasgow Outcome Scale; GOS), follow-up time and indication for the use of TOCF. Results: All patients (N = 7) were male with a mean age of 64 years and a mean BMI of 29. The mean ISS was 45, with the lowest ISS of 25, indicating that only polytraumatized patients were included. Two anterior-posterior-compression-, four lateral-compression-, and one vertical-shear-pelvic-injury were identified. TOCF was added in six cases to support symphyseal plating and in one case to external fixation. The mean hospital stay was 49 days and the mean follow-up duration was 8.5 months. No complications associated with TOCF were observed during the surgical procedure or follow-up. Conclusion: TOCF showed no procedure-associated complications and effectively supported symphyseal healing in all cases. The main indications were obesity, poor bone quality in elderly patients, and revision cases. TOCF could be considered as a last treatment option in open-book pelvic injuries where plating or external fixation is at risk to fail.