Yolanda Moliner

Dr. Yolanda Moliner


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2014 in Nanomaterials
Verified
Journal Article
Open access
PDF file
RGR. A. González-Fuenzalida
R. A. González-Fuenzalida
YMYolanda Moliner
Yolanda Moliner
HGHelena Prima Garcia
Helena Prima Garcia
ARAntonio Ribera
Antonio Ribera
Pilar Campíns-FalcóPilar Campíns-Falcó
Pilar Campíns-Falcó
RZRamon J. Zaragozá
Ramon J. Zaragozá
The use of magnetic nanomaterials for analytical applications has increased in the recent years. In particular, magnetic nanomaterials have shown great potential as adsorbent phase in several extraction procedures due to the significant advantages over the conventional methods. In the present work, the influence of magnetic forces over the extraction efficiency of triazines using superparamagnetic silica nanoparticles (NPs) in magnetic in tube solid phase microextraction (Magnetic-IT-SPME) coupled to CapLC has been evaluated. Atrazine, terbutylazine and simazine has been selected as target analytes. The superparamagnetic silica nanomaterial (SiO2-Fe3O4) deposited onto the surface of a capillary column gave rise to a magnetic extraction phase for IT-SPME that provided a enhancemment of the extraction efficiency for triazines. This improvement is based on two phenomena, the superparamegnetic behavior of Fe3O4 NPs and the diamagnetic repulsions that take place in a microfluidic device such a capillary column. A systematic study of analytes adsorption and desorption was conducted as function of the magnetic field and the relationship with triazines magnetic susceptibility. The positive influence of magnetism on the extraction procedure was demonstrated. The analytical characteristics of the optimized procedure were established and the method was applied to the determination of the target analytes in water samples with satisfactory results. When coupling Magnetic-IT-SPME with CapLC, improved adsorption efficiencies (60%–63%) were achieved compared with conventional adsorption materials (0.8%–3%).

1 November 2016 in Science of The Total Environment
Verified
Journal Article
Closed access
JPJ. Pla-Tolós
J. Pla-Tolós
PSP. Serra-Mora
P. Serra-Mora
LHL. Hakobyan
L. Hakobyan
CMCarmen Molíns-Legua
Carmen Molíns-Legua
YMYolanda Moliner
Yolanda Moliner
Pilar Campíns-FalcóPilar Campíns-Falcó
Pilar Campíns-Falcó

1 March 2016 in Separations
Verified
Journal Article
Open access
PDF file
AAAna Isabel Argente-García
Ana Isabel Argente-García
YMYolanda Moliner
Yolanda Moliner
ELEsther López-García
Esther López-García
Pilar Campíns-FalcóPilar Campíns-Falcó
Pilar Campíns-Falcó
RHRosa Herráez-Hernández
Rosa Herráez-Hernández
In this study, polydimethylsiloxane (PDMS)-coated capillary columns (TRB-5 and TRB-35), both unmodified and functionalized with single-wall carbon nanotubes (SWCNTs) or multiwall carbon nanotubes (MWCNTs), have been tested and compared for the extraction of amphetamine (AMP), methamphetamine (MET) and ephedrine (EPE) by in-tube solid-phase microextraction (IT-SPME). Prior to their extraction, the analytes were derivatized with the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC). For separation and detection capillary chromatography with fluorimetric detection has been used. The presence of carbon nanotubes in the extractive coatings enhanced the extraction efficiencies and also significantly improved the chromatographic profiles, thus resulting in a reliable option for the analysis of these drugs. As an example of application, a new method is proposed for the analysis of the tested amphetamines in oral fluid using a TRB-35 capillary column functionalized with MWCNTs. The proposed conditions provided suitable selectivity and reproducibility (CV ≤ 6%, n = 3) at low µg/mL levels, and limits of detection of 0.5–0.8 µg/mL.

5 April 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
APAaron Boughbina Portolés
Aaron Boughbina Portolés
LNLorenzo Sanjuan Navarro
Lorenzo Sanjuan Navarro
YMYolanda Moliner
Yolanda Moliner
Pilar Campíns-FalcóPilar Campíns-Falcó
Pilar Campíns-Falcó
Asymmetrical flow field-flow fractionation (AF4) coupled to UV-Vis and dynamic light scattering (DLS) detectors in series, was tested for stability studies of dispersions of citrate-capped silver nanoparticles (AgNPs) in several water matrices. The main goal is to provide knowledge to understand their possible behavior in the environment for short times since mixturing (up to 180 min). Ultrapure (UPW), bottled (BW1, BW2), tap (TW), transitional (TrW) and sea water (SW) matrices were assayed. Observations were compatible with the aggregation of AgNPs, a change in the plasmon band and a size growth with time were done. Fractograms showed different evolution fingerprints in the function of the waters and batches. The aggregation rate order was BW2, SW, TrW, BW1 and TW, being BW2 the lowest and TW the highest. NP aggregation can be induced by increasing the salt concentration of the medium, however transitional and sea waters did not follow the rule. Both matrices presented a lower aggregation rate in comparison with other aqueous matrices with much lower ionic strength (BW1 and TW), which can be explained by the potential presence of dissolved organic matter and/or the high concentration of halides providing their stabilization and passivation, respectively. AF4 provides relevant information with respect to static DLS and UV-Vis Spectroscopy showing that at least two populations of aggregates with different sizes between them, depending on both, the mixture time for a given matrix and type of water matrix for the same time.

1 March 2018 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
LHL. Hakobyan
L. Hakobyan
JTJ. Pla Tolos
J. Pla Tolos
YMYolanda Moliner
Yolanda Moliner
CMCarmen Molíns-Legua
Carmen Molíns-Legua
JRJesús Ruiz Ramos
Jesús Ruiz Ramos
Pilar Campíns-FalcóPilar Campíns-Falcó
Pilar Campíns-Falcó

1 January 2014 in Journal of Chromatography A
Verified
Journal Article
Closed access
MMM. Muñoz-Ortuño
M. Muñoz-Ortuño
AAA. Argente-García
A. Argente-García
YMYolanda Moliner
Yolanda Moliner
JVJorge Verdú-Andrés
Jorge Verdú-Andrés
RHRosa Herráez-Hernández
Rosa Herráez-Hernández
Pilar Campíns-FalcóPilar Campíns-Falcó
Pilar Campíns-Falcó