Tamara Grujic

Prof. Dr. Tamara Grujic


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2011 in Clinical Biomechanics
Verified
Journal Article
Closed access
TGTamara Grujic
Tamara Grujic
TBTadej Bajd
Tadej Bajd
Gregorij KurilloGregorij Kurillo
Gregorij Kurillo

1 July 2013 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
Ivo StancicIvo Stancic
Ivo Stancic
TGTamara Grujic
Tamara Grujic
APAnte Panjkota
Ante Panjkota
The precise measurement and analysis of human movements is an essential step in biomechanical research used in sports or medicine. Measurement systems used for motion tracking should be non‐invasive, safe to use, widely customisable and cost‐efficient. In this study, complete design, development and evaluation of a high‐speed optical motion tracking and analysis system is described. The system aims to analyse movements for sports and medical applications. The novelty of the proposed system is its design, which is based on visible light light‐emitting diode (LED) markers, rather than infrared markers that are commonly used, and a pair of high‐speed digital cameras. Calibration procedures and a super‐resolution marker model are introduced, ensuring sub‐pixel marker centre detection which results in higher three‐dimensional reconstruction accuracy. Evaluation of the system included an accuracy test of the proposed system on static and moving objects with known dimensions, followed by analysis of kinematic data obtained in dynamic conditions while measuring human gait. The evaluation results are presented, and conclusions about system performance with possible improvements are discussed.

1 November 2012 in International Journal of Advanced Robotic Systems
Verified
Journal Article
Open access
Ivo StancicIvo Stancic
Ivo Stancic
TGTamara Grujic
Tamara Grujic
MBMirjana Bonkovic
Mirjana Bonkovic
Gait patterns of humans and humanoid robots are often described by analysing changes in angular rotation of hip, knee and ankle joints during one gait cycle. Each joint displays specific behaviour and irregularities of the gait pattern could be detected by measuring displacements from the normal rotation curve, while small deviations of individual gait characteristics are usually not easily detected. In this paper, an advanced gait analysis method is proposed, which incorporates analysis of angular data and its derivations of hip, knee, and ankle joints, presented in the phase plane. The gait kinematics was measured using a system based on active markers and fast digital cameras. The experiment included measurements on thirty healthy, barefoot humans while walking on a treadmill. We also simulated types of irregular gait, by measurements on subjects wearing knee constraints. The new kinematic parameters which are introduced clearly indicated the discrepancy between normal, healthy gait trials and irregular gait trials. The proposed gait factor parameter is a valuable measure for the detection of irregularities in gait patterns of humans and humanoid robots.