weihua pei

Prof. weihua pei


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2023 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
YWYang Wang
Yang Wang
XYXinze Yang
Xinze Yang
XZXiwen Zhang
Xiwen Zhang
YWYijun Wang
Yijun Wang
WPweihua pei
weihua pei
Implantable intracortical microelectrodes can record a neuron’s rapidly changing action potentials (spikes). In vivo neural activity recording methods often have either high temporal or spatial resolution, but not both. There is an increasing need to record more neurons over a longer duration in vivo. However, there remain many challenges to overcome before achieving long-term, stable, high-quality recordings and realizing comprehensive, accurate brain activity analysis. Based on the vision of an idealized implantable microelectrode device, the performance requirements for microelectrodes are divided into four aspects, including recording quality, recording stability, recording throughput, and multifunctionality, which are presented in order of importance. The challenges and current possible solutions for implantable microelectrodes are given from the perspective of each aspect. The current developments in microelectrode technology are analyzed and summarized.

2 October 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XXXiao Xing
Xiao Xing
YWYijun Wang
Yijun Wang
WPweihua pei
weihua pei
XGXuhong Guo
Xuhong Guo
ZLZhiduo Liu
Zhiduo Liu
HCHongda Chen
Hongda Chen
A high-speed steady-state visual evoked potentials (SSVEP)-based brain-computer interface (BCI) system using dry EEG electrodes was demonstrated in this study. The dry electrode was fabricated in our laboratory. It was designed as claw-like structure with a diameter of 14 mm, featuring 8 small fingers of 6 mm length and 2 mm diameter. The structure and elasticity can help the fingers pass through the hair and contact the scalp when the electrode is placed on head. The electrode was capable of recording spontaneous EEG and evoked brain activities such as SSVEP with high signal-to-noise ratio. This study implemented a twelve-class SSVEP-based BCI system with eight electrodes embedded in a headband. Subjects also completed a comfort level questionnaire with the dry electrodes. Using a preprocessing algorithm of filter bank analysis (FBA) and a classification algorithm based on task-related component analysis (TRCA), the average classification accuracy of eleven participants was 93.2% using 1-second-long SSVEPs, leading to an average information transfer rate (ITR) of 92.35 bits/min. All subjects did not report obvious discomfort with the dry electrodes. This result represented the highest communication speed in the dry-electrode based BCI systems. The proposed system could provide a comfortable user experience and a stable control method for developing practical BCIs.

12 May 2021 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
ZLZhiduo Liu
Zhiduo Liu
GWGang Wang
Gang Wang
CYChen Ye
Chen Ye
HSHongyan Sun
Hongyan Sun
WPweihua pei
weihua pei
Guozhen ShenGuozhen Shen
Guozhen Shen

1 October 2021 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
GMGege Ming
Gege Ming
WPweihua pei
weihua pei
HCHongda Chen
Hongda Chen
XGXiaorong Gao
Xiaorong Gao
YWYijun Wang
Yijun Wang
Objective. Low-frequency steady-state visual evoked potential (SSVEP)-based brain–computer interface (BCI) systems with high performance are prone to cause visual discomfort and fatigue. High-frequency SSVEP-based BCI systems can alleviate the discomfort, but always obtain lower performance. This study optimized the spatial properties of a proposed checkerboard-like visual stimulus toward high-performance and user-friendly SSVEP-based BCI systems. Approach. On the one hand, two checkerboard-like stimuli with distinct spatial contrasts (the black- and white-background) were designed to balance the tradeoff between BCI performance and user experience and compared with the traditional flickering stimulus. On the other hand, the impacts of the spatial frequency of the new checkerboard-like stimulus on the flicker perception and the intensity of the elicited SSVEP were clarified. The SSVEP-based BCI systems were implemented based on the checkerboard-like stimuli under low-frequency and high-frequency conditions. The user experience for each stimulation pattern was estimated by questionnaires for subjective evaluation. Main results. The comparison results indicate that the black-background checkerboard-like stimulus with an optimized spatial frequency achieved comparable performance and enhanced visual comfort compared with the flickering stimulus. Furthermore, the online nine-target BCI system using the black-background checkerboard-like stimuli achieved averaged information transfer rates of 124.0 ± 2.3 and 109.0 ± 20.4 bits min −1 with low-frequency and high-frequency stimulation respectively. Significance. The new checkerboard-like stimuli with optimized properties show superiority of system performance and user experience in implementing SSVEP-based BCI, which will promote its practical applications in communication and control.

16 August 2021 in Frontiers in Integrative Neuroscience
Verified
Journal Article
Open access
XWXiaoting Wu
Xiaoting Wu
XYXiangyu Yang
Xiangyu Yang
LSLulu Song
Lulu Song
YWYang Wang
Yang Wang
YLYamin Li
Yamin Li
WLWeidong Li
Weidong Li
The miniscope system is one of the calcium (Ca2+) imaging tools with small size and lightweight and can realize the deep-brain Ca2+ imaging not confined to the cerebral cortex. Combining Ca2+ imaging and electrophysiology recording has been an efficient method for extracting high temporal-spatial resolution signals in the brain. In this study, a particular electrode probe was developed and assembled on the imaging lens to modify the miniscope system. The electrode probe can be tightly integrated into the lens of the miniscope without increasing the volume, weight, and implantation complexity. In vivo tests verified that the proposed modified system has realized the simultaneous recording of Ca2+ signals and local field potential (LFP) signal in the hippocampus CA1 region of an adult mouse.

12 May 2022 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
CWChunrong Wei
Chunrong Wei
YWYang Wang
Yang Wang
WPweihua pei
weihua pei
XHXinyong Han
Xinyong Han
LLLongnian Lin
Longnian Lin
YWYijun Wang
Yijun Wang
Flexible multichannel electrode arrays (fMEAs) with multiple filaments can be flexibly implanted in various patterns. It is necessary to develop a method for implanting the fMEA in different locations and at various depths based on the recording demands. This study proposed a strategy for reducing the microelectrode volume with integrated packaging. An implantation system was developed specifically for semiautomatic distributed implantation. The feasibility and convenience of the fMEA and implantation platform were verified in rodents. The acute and chronic recording results provied the effectiveness of the packaging and implantation methods. These methods could provide a novel strategy for developing fMEAs with more filaments and recording sites to measure functional interactions across multiple brain regions.