Human locomotion involves continuously variable activities including walking, running, and stair climbing over a range of speeds and inclinations as well as sit-stand, walk-run, and walk-stairs transitions. Understanding the kinematics and kinetics of the lower limbs during continuously varying locomotion is fundamental to developing robotic prostheses and exoskeletons that assist in community ambulation. However, available datasets on human locomotion neglect transitions between activities and/or continuous variations in speed and inclination during these activities. This data paper reports a new dataset that includes the lower-limb kinematics and kinetics of ten able-bodied participants walking at multiple inclines (±0°; 5° and 10°) and speeds (0.8 m/s; 1 m/s; 1.2 m/s), running at multiple speeds (1.8 m/s; 2 m/s; 2.2 m/s and 2.4 m/s), walking and running with constant acceleration (±0.2; 0.5), and stair ascent/descent with multiple stair inclines (20°; 25°; 30° and 35°). This dataset also includes sit-stand transitions, walk-run transitions, and walk-stairs transitions. Data were recorded by a Vicon motion capture system and, for applicable tasks, a Bertec instrumented treadmill.
25 March 2019 in IEEE/ASME Transactions on Mechatronics
Compared to rigid actuators, series elastic actuators (SEAs) offer a potential reduction of motor energy consumption and peak power, though these benefits are highly dependent on the design of the torque-elongation profile of the elastic element. In the case of linear springs, natural dynamics is a traditional method for this design, but it has two major limitations-arbitrary load trajectories are difficult or impossible to analyze and it does not consider actuator constraints. Parametric optimization is also a popular design method that addresses these limitations, but solutions are only optimal within the space of the parameters. To overcome these limitations, we propose a nonparametric convex optimization program for the design of the nonlinear elastic element that minimizes energy consumption and peak power for an arbitrary periodic reference trajectory. To obtain convexity, we introduce a convex approximation to the expression of peak power; energy consumption is shown to be convex without approximation. The combination of peak power and energy consumption in the cost function leads to a multiobjective convex optimization framework that comprises the main contribution of this paper. As a case study, we recover the elongation-torque profile of a cubic spring, given its natural oscillation as the reference load. We then design nonlinear SEAs for an ankle prosthesis that minimize energy consumption and peak power for different trajectories and extend the range of achievable tasks when subject to actuator constraints.
10 June 2020 in IEEE Robotics and Automation Letters
Recently, it has been shown that light-weight, passive, ankle exoskeletons with spring-based energy store-and-release mechanisms can reduce the muscular effort of human walking. The stiffness of the spring in such a device must be properly tuned in order to minimize the muscular effort. However, this muscular effort changes for different locomotion conditions (e.g., walking speed), causing the optimal spring stiffness to vary as well. Existing passive exoskeletons have a fixed stiffness during operation, preventing it from responding to changes in walking conditions. Thus, there is a need of a device and auto-tuning algorithm that minimizes the muscular effort across different walking conditions, while preserving the advantages of passive exoskeletons. In this paper, we developed a quasi-passive ankle exoskeleton with a variable stiffness mechanism capable of self-tuning. As the relationship between the muscular effort and the optimal spring stiffness across different walking speeds is not known a priori, a model-free, discrete-time extremum seeking control (ESC) algorithm was implemented for real-time optimization of spring stiffness. Experiments with an able-bodied subject demonstrate that as the walking speed of the user changes, ESC automatically tunes the torsional stiffness about the ankle joint. The average RMS EMG readings of tibialis anterior and soleus muscles at slow walking speed decreased by 26.48% and 7.42%, respectively.
15 September 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Current supervised learning or deep learning-based activity recognition classifiers can achieve high accuracy in recognizing locomotion activities. Most available techniques use a high-dimensional space of features, e.g., combinations of EMG, kinematics and kinetics, and transformations over those signals. The associated classification rules are therefore complex; the machine tries to understand the human, but the human does not understand the machine. This paper presents an activity recognition system that uses signals from a thigh-mounted IMU and a force sensitive resistor to classify transitions between sitting, walking, stair ascending, and stair descending. The system uses the thigh's orientation and velocity with foot contact information at specific moments within a given activity as the features to classify transitions to other activities. We call these Instantaneous Characteristic Features (ICFs). Because these ICFs are biomechanically intuitive, they are easy for the user to understand and thus control the activity transitions of wearable robots. We assessed our classification algorithm offline using an existing dataset with 10 able-bodied subjects and online with another 10 able-bodied subjects wearing a real-time system. The offline study analyzed the effect of subject-dependency and ramp inclinations. The real-time classification accuracy was evaluated before and after training the subjects on the ICFs. The real-time system achieved overall pre-subject-training and post-subject-training error rates of 0.59% ± 0.24% and 0.56% ± 0.20%, respectively. We also evaluated the feasibility of our ICFs for amputee ambulation by analyzing a public dataset with the open-source bionic leg. The simplicity of these classification rules demonstrates a new paradigm for activity recognition where the human can understand the machine and vice-versa.
22 June 2022 in IEEE Transactions on Medical Robotics and Bionics
Although emerging powered prostheses can enable people with lower-limb amputation to walk and climb stairs over different task conditions (e.g., speeds and inclines), the control architecture typically uses a finite-state machine to switch between activity-specific controllers. Because these controllers focus on steady-state locomotion, powered prostheses abruptly switch between controllers during gait transitions rather than continuously adjusting leg biomechanics in synchrony with the users. This paper introduces a new framework for powered prosthesis control by modeling the lower-limb joint kinematics over a continuum of variable-incline walking and stair climbing, including steady-state and transitional gaits. Steady-state models for walking and stair climbing represent joint kinematics as continuous functions of gait phase, forward speed, and incline. Transition models interpolate kinematics as convex combinations of the two steady-state models, with an additional term to account for kinematics that fall outside their convex hull. The coefficients of this convex combination denote the similarity of the transitional kinematics to each steady-state mode, providing insight into how able-bodied individuals continuously transition between ambulation modes. Cross-validation demonstrates that the model predictions of untrained kinematics have errors within the range of physiological variability for all joints. Simulation results demonstrate the model’s robustness to incline estimation and mode classification errors.
The use of actuators with inherent compliance, such as series elastic actuators (SEAs), has become traditional for robotic systems working in close contact with humans. SEAs can reduce the energy consumption for a given task compared to rigid actuators, but this reduction is highly dependent on the design of the SEA’s elastic element. This design is often based on natural dynamics or a parameterized optimization, but both approaches have limitations. The natural dynamics approach cannot consider actuator constraints or arbitrary reference trajectories, and a parameterized elastic element can only be optimized within the given parameter space. In this work, we propose a solution to these limitations by formulating the design of the SEA’s elastic element as a non-parametric convex optimization problem, which yields a globally optimal conservative elastic element while respecting actuator constraints. Convexity is proven for the case of an arbitrary periodic reference trajectory with a SEA capable of energy regeneration. We discuss the optimization results for the tasks defined by the human ankle motion during level-ground walking and the natural motion of a single mass-spring system with a nonlinear spring. For all these tasks, the designed SEA reduces energy consumption and satisfies the actuator’s constraints.