Computer-assisted surgery is becoming essential in modern medicine to accurately plan, guide, and perform surgeries. Similarly, Digital Twin technology is expected to be instrumental in the future of surgery, owing to its capacity to virtually replicate patient-specific interventions whilst providing real-time updates to clinicians. This perspective introduces the term Digital Twin-Assisted Surgery and discusses its potential to improve surgical precision and outcome, along with key challenges for successful clinical translation.
The outstanding locomotor and manipulation characteristics of the octopus have recently inspired the development, by our group, of multi-functional robotic swimmers, featuring both manipulation and locomotion capabilities, which could be of significant engineering interest in underwater applications. During its little-studied arm-swimming behavior, as opposed to the better known jetting via the siphon, the animal appears to generate considerable propulsive thrust and rapid acceleration, predominantly employing movements of its arms. In this work, we capture the fundamental characteristics of the corresponding complex pattern of arm motion by a sculling profile, involving a fast power stroke and a slow recovery stroke. We investigate the propulsive capabilities of a multi-arm robotic system under various swimming gaits, namely patterns of arm coordination, which achieve the generation of forward, as well as backward, propulsion and turning. A lumped-element model of the robotic swimmer, which considers arm compliance and the interaction with the aquatic environment, was used to study the characteristics of these gaits, the effect of various kinematic parameters on propulsion, and the generation of complex trajectories. This investigation focuses on relatively high-stiffness arms. Experiments employing a compliant-body robotic prototype swimmer with eight compliant arms, all made of polyurethane, inside a water tank, successfully demonstrated this novel mode of underwater propulsion. Speeds of up to 0.26 body lengths per second (approximately 100 mm s(-1)), and propulsive forces of up to 3.5 N were achieved, with a non-dimensional cost of transport of 1.42 with all eight arms and of 0.9 with only two active arms. The experiments confirmed the computational results and verified the multi-arm maneuverability and simultaneous object grasping capability of such systems.
11 May 2023 in Frontiers in Bioengineering and Biotechnology
Introduction: Patient-specific computational fluid dynamics (CFD) models permit analysis of complex intra-aortic hemodynamics in patients with aortic dissection (AD), where vessel morphology and disease severity are highly individualized. The simulated blood flow regime within these models is sensitive to the prescribed boundary conditions (BCs), so accurate BC selection is fundamental to achieve clinically relevant results.Methods: This study presents a novel reduced-order computational framework for the iterative flow-based calibration of 3-Element Windkessel Model (3EWM) parameters to generate patient-specific BCs. These parameters were calibrated using time-resolved flow information derived from retrospective four-dimensional flow magnetic resonance imaging (4D Flow-MRI). For a healthy and dissected case, blood flow was then investigated numerically in a fully coupled zero dimensional-three dimensional (0D-3D) numerical framework, where the vessel geometries were reconstructed from medical images. Calibration of the 3EWM parameters was automated and required ~3.5 min per branch.Results: With prescription of the calibrated BCs, the computed near-wall hemodynamics (time-averaged wall shear stress, oscillatory shear index) and perfusion distribution were consistent with clinical measurements and previous literature, yielding physiologically relevant results. BC calibration was particularly important in the AD case, where the complex flow regime was captured only after BC calibration.Discussion: This calibration methodology can therefore be applied in clinical cases where branch flow rates are known, for example, via 4D Flow-MRI or ultrasound, to generate patient-specific BCs for CFD models. It is then possible to elucidate, on a case-by-case basis, the highly individualized hemodynamics which occur due to geometric variations in aortic pathology high spatiotemporal resolution through CFD.
Inspired by the octopus arm morphology and exploiting recordings of swimming octopus, we investigate the propulsive capabilities of an 8-arm robotic system under various swimming gaits, including arm sculling and arm undulations, for the generation of forward propulsion. A dynamical model of the robotic system, that considers fluid drag contributions accurately evaluated by CFD methods, was used to study the effects of various kinematic parameters on propulsion. Experiments inside a water tank with an 8-arm robotic prototype successfully demonstrated the sculling-only gaits, attaining a maximum speed of approximately 0.2 body lengths per second. Similar trends were observed, as in the simulation studies, with respect to the effect of the kinematic parameters on propulsion.
4 July 2012 in Journal of The Royal Society Interface
Mice are widely used to investigate atherogenesis, which is known to be influenced by stresses related to blood flow. However, numerical characterization of the haemodynamic environment in the commonly studied aortic arch has hitherto been based on idealizations of inflow into the aorta. Our purpose in this work was to numerically characterize the haemodynamic environment in the mouse aortic arch using measured inflow velocities, and to relate the resulting shear stress patterns to known locations of high- and low-lesion prevalence. Blood flow velocities were measured in the aortic root of C57/BL6 mice using phase-contrast MRI. Arterial geometries were obtained by micro-CT of corrosion casts. These data were used to compute blood flow and wall shear stress (WSS) patterns in the arch. WSS profiles computed using realistic and idealized aortic root velocities differed significantly. An unexpected finding was that average WSS in the high-lesion-probability region on the inner wall was actually higher than the WSS in the low-probability region on the outer wall. Future studies of mouse aortic arch haemodynamics should avoid the use of idealized inflow velocity profiles. Lesion formation does not seem to uniquely associate with low or oscillating WSS in this segment, suggesting that other factors may also play a role in lesion localization.
This paper presents an 8-arm compliant robot, able to propel itself underwater by movements of its arms, either alone or interconnected via a passively-compliant web. The robot is inspired by the morphology and outstanding locomotor capabilities of the octopus, and is fabricated primarily from compliant materials. This robotic swimmer is first investigated computationally via dynamical models capturing the arm and web compliance, and indicating the effect of various kinematic parameters of the system on its motion. The performance of the robotic prototype is, then, tested experimentally, to demonstrate this novel mode of underwater propulsion by combining various patterns of sculling movements of the arms and web. Speeds of 0.5 body lengths per second and propulsive forces of up to 10.5 N were achieved, with a cost of transport as low as 0.62.