Riwa Kishimoto

Riwa Kishimoto

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2019 in European Radiology
Verified
Journal Article
Open access
PDF file
RKRiwa Kishimoto
Riwa Kishimoto
KKKatsuhiko Kikuchi
Katsuhiko Kikuchi
AKAtsuhisa Koyama
Atsuhisa Koyama
JKJeff Kershaw
Jeff Kershaw
TOTokuhiko Omatsu
Tokuhiko Omatsu
TOTakayuki Obata
Takayuki Obata
This study was conducted in order to assess the intra- and interoperator reproducibility of shear-wave speed (SWS) measurement on elasticity phantoms and healthy volunteers using ultrasound-based point shear-wave elastography.

5 January 2017 in BMJ Open
Verified
Journal Article
Open access
RKRiwa Kishimoto
Riwa Kishimoto
MSMikio Suga
Mikio Suga
AKAtsuhisa Koyama
Atsuhisa Koyama
TOTokuhiko Omatsu
Tokuhiko Omatsu
YTYasuhiko Tachibana
Yasuhiko Tachibana
TOTakayuki Obata
Takayuki Obata
Objectives: To compare shear-wave speed (SWS) measured by ultrasound-based point shear-wave elastography (pSWE) and MR elastography (MRE) on phantoms with a known shear modulus, and to assess method validity and variability.Methods: 5 homogeneous phantoms of different stiffnesses were made. Shear modulus was measured by a rheometer, and this value was used as the standard. 10 SWS measurements were obtained at 4 different depths with 1.0–4.5 MHz convex (4C1) and 4.0–9.0 MHz linear (9L4) transducers using pSWE. MRE was carried out once per phantom, and SWSs at 5 different depths were obtained. These SWSs were then compared with those from a rheometer using linear regression analyses.Results: SWSs obtained with both pSWE as well as MRE had a strong correlation with those obtained by a rheometer (R2>0.97). The relative difference in SWS between the procedures was from −25.2% to 25.6% for all phantoms, and from −8.1% to 6.9% when the softest and hardest phantoms were excluded. Depth dependency was noted in the 9L4 transducer of pSWE and MRE.Conclusions: SWSs from pSWE and MRE showed a good correlation with a rheometer-determined SWS. Although based on phantom studies, SWSs obtained with these methods are not always equivalent, the measurement can be thought of as reliable and these SWSs were reasonably close to each other for the middle range of stiffness within the measurable range.

1 September 2009 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
ISItsuko Serizawa
Itsuko Serizawa
RIReiko Imai
Reiko Imai
TKTadashi Kamada
Tadashi Kamada
HTHiroshi Tsuji
Hiroshi Tsuji
RKRiwa Kishimoto
Riwa Kishimoto
STShin-Ichiro Tatezaki
Shin-Ichiro Tatezaki
Objective: We evaluated changes in tumor volume in cases of sacral chordoma after carbon ion radiotherapy. Methods: Thirty-four patients with sacral chordoma underwent carbon ion radiotherapy between June 1996 and June 2003. We assessed 23 patients without previous surgery using T2-weighted magnetic resonance imaging. The tumor volume was calculated semiautomatically. Results: Two cases showed local recurrence. The median interval of this examination was 46 months. At the end of the treatment, the tumor showed an enlargement larger than 10% of its volume in 13 of the 23 cases, no change in 4 cases, and regression in 6 cases. At the last examination, 20 cases showed a reduction in tumor volume, and the median ratio, determined as the tumor volume at the last examination divided by that before the treatment, was 0.36. Conclusions: An increase in tumor volume at the end of the treatment does not indicate the ineffectiveness of carbon ion radiotherapy.

25 February 2008 in Journal of Neurology
Verified
Journal Article
Closed access
PDF file
RKRiwa Kishimoto
Riwa Kishimoto
IYIchiro Yabe
Ichiro Yabe
MNM. Niino
M. Niino
KSK. Sato
K. Sato
STS. Tsuji
S. Tsuji
HSH. Sasaki
H. Sasaki

21 May 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MUMasashi Usumura
Masashi Usumura
RKRiwa Kishimoto
Riwa Kishimoto
KIKoki Ishii
Koki Ishii
EHEika Hotta
Eika Hotta
JKJeff Kershaw
Jeff Kershaw
MSMikio Suga
Mikio Suga
We evaluated the long-term stability of a newly developed viscoelastic phantom made of polyacrylamide (PAAm) gel for magnetic resonance elastography (MRE) and ultrasound-based shear-wave elastography (US SWE). The stiffness of the cylindrical phantom was measured at 0, 13 and 18 months. Storage and loss moduli were measured with MRE, and shear-wave speed (SWS) was measured with US SWE. Long-term stability was evaluated in accordance with the Quantitative Imaging Biomarker Alliance (QIBA) profiles for each modality. The initial storage and loss moduli of the phantom were 5.01±0.22 and 1.11±0.15 respectively, and SWS was 2.57±0.04 m/s. The weight of the phantom decreased by 0.6% over the 18 months. When measured with MRE, the stiffness of the phantom decreased and changes to the storage and loss moduli were -3.0% and -4.6% between 0 and 13 months, and -4.3% and 0.0% between 0 and 18 months. The US measurements found that SWS decreased by 2.4% over the first 13 months and 3.6% at 18 months. These changes were smaller than the tolerances specified in the QIBA profiles, so the viscoelastic PAAm gel phantom fulfilled the condition for long-term stability. This new phantom has the potential to be used as a quality assurance and quality control phantom for MRE and US SWE.

1 May 2007 in European Journal of Radiology
Verified
Journal Article
Closed access
SMShinichiro Mori
Shinichiro Mori
TOTakayuki Obata
Takayuki Obata
HKHirotoshi Kato
Hirotoshi Kato
RKRiwa Kishimoto
Riwa Kishimoto
SKSusumu Kandatsu
Susumu Kandatsu
MEMasahiro Endo
Masahiro Endo