Lun-De Liao

Prof. Lun-De Liao

Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2011 in Reviews in the Neurosciences
Verified
Journal Article
Closed access
PDF file
KGKlaus Gramann
Klaus Gramann
JGJoseph T. Gwin
Joseph T. Gwin
DFDaniel Ferris
Daniel Ferris
KOKelvin Oie
Kelvin Oie
TJTzyy-Ping Jung
Tzyy-Ping Jung
SMScott Makeig
Scott Makeig
We have recently developed a mobile brain imaging method (MoBI), that allows for simultaneous recording of brain and body dynamics of humans actively behaving in and interacting with their environment. A mobile imaging approach was needed to study cognitive processes that are inherently based on the use of human physical structure to obtain behavioral goals. This review gives examples of the tight coupling between human physical structure with cognitive processing and the role of supraspinal activity during control of human stance and locomotion. Existing brain imaging methods for actively behaving participants are described and new sensor technology allowing for mobile recordings of different behavioral states in humans is introduced. Finally, we review recent work demonstrating the feasibility of a MoBI system that was developed at the Swartz Center for Computational Neuroscience at the University of California, San Diego, demonstrating the range of behavior that can be investigated with this method.

30 December 2010 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
CLChin-Teng Lin
Chin-Teng Lin
Lun-De LiaoLun-De Liao
Lun-De Liao
YLYu-Hang Liu
Yu-Hang Liu
IWI-Jan Wang
I-Jan Wang
BLBor-Shyh Lin
Bor-Shyh Lin
JCJyh-Yeong Chang
Jyh-Yeong Chang
A novel dry foam-based electrode for long-term EEG measurement was proposed in this study. In general, the conventional wet electrodes are most frequently used for EEG measurement. However, they require skin preparation and conduction gels to reduce the skin-electrode contact impedance. The aforementioned procedures when wet electrodes were used usually make trouble to users easily. In order to overcome the aforesaid issues, a novel dry foam electrode, fabricated by electrically conductive polymer foam covered by a conductive fabric, was proposed. By using conductive fabric, which provides partly polarizable electric characteristic, our dry foam electrode exhibits both polarization and conductivity, and can be used to measure biopotentials without skin preparation and conduction gel. In addition, the foam substrate of our dry electrode allows a high geometric conformity between the electrode and irregular scalp surface to maintain low skin-electrode interface impedance, even under motion. The experimental results presented that the dry foam electrode performs better for long-term EEG measurement, and is practicable for daily life applications.

28 January 2012 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
Lun-De LiaoLun-De Liao
Lun-De Liao
CCChi-Yu Chen
Chi-Yu Chen
IWI-Jan Wang
I-Jan Wang
SCSheng-Fu Chen
Sheng-Fu Chen
SLShih-Yu Li
Shih-Yu Li
CLChin-Teng Lin
Chin-Teng Lin
A brain-computer interface (BCI) is a communication system that can help users interact with the outside environment by translating brain signals into machine commands. The use of electroencephalographic (EEG) signals has become the most common approach for a BCI because of their usability and strong reliability. Many EEG-based BCI devices have been developed with traditional wet- or micro-electro-mechanical-system (MEMS)-type EEG sensors. However, those traditional sensors have uncomfortable disadvantage and require conductive gel and skin preparation on the part of the user. Therefore, acquiring the EEG signals in a comfortable and convenient manner is an important factor that should be incorporated into a novel BCI device. In the present study, a wearable, wireless and portable EEG-based BCI device with dry foam-based EEG sensors was developed and was demonstrated using a gaming control application. The dry EEG sensors operated without conductive gel; however, they were able to provide good conductivity and were able to acquire EEG signals effectively by adapting to irregular skin surfaces and by maintaining proper skin-sensor impedance on the forehead site. We have also demonstrated a real-time cognitive stage detection application of gaming control using the proposed portable device. The results of the present study indicate that using this portable EEG-based BCI device to conveniently and effectively control the outside world provides an approach for researching rehabilitation engineering.

30 May 2011 in Sensors
Verified
Journal Article
Open access
PDF file
Lun-De LiaoLun-De Liao
Lun-De Liao
IWI-Jan Wang
I-Jan Wang
SCSheng-Fu Chen
Sheng-Fu Chen
JCJyh-Yeong Chang
Jyh-Yeong Chang
CLChin-Teng Lin
Chin-Teng Lin
In the present study, novel dry-contact sensors for measuring electro-encephalography (EEG) signals without any skin preparation are designed, fabricated by an injection molding manufacturing process and experimentally validated. Conventional wet electrodes are commonly used to measure EEG signals; they provide excellent EEG signals subject to proper skin preparation and conductive gel application. However, a series of skin preparation procedures for applying the wet electrodes is always required and usually creates trouble for users. To overcome these drawbacks, novel dry-contact EEG sensors were proposed for potential operation in the presence or absence of hair and without any skin preparation or conductive gel usage. The dry EEG sensors were designed to contact the scalp surface with 17 spring contact probes. Each probe was designed to include a probe head, plunger, spring, and barrel. The 17 probes were inserted into a flexible substrate using a one-time forming process via an established injection molding procedure. With these 17 spring contact probes, the flexible substrate allows for high geometric conformity between the sensor and the irregular scalp surface to maintain low skin-sensor interface impedance. Additionally, the flexible substrate also initiates a sensor buffer effect, eliminating pain when force is applied. The proposed dry EEG sensor was reliable in measuring EEG signals without any skin preparation or conductive gel usage, as compared with the conventional wet electrodes.

3 November 2014 in Small
Verified
Journal Article
Closed access
PDF file
JGJunlong Geng
Junlong Geng
CSChunyang Sun
Chunyang Sun
JLJie Liu
Jie Liu
Lun-De LiaoLun-De Liao
Lun-De Liao
YYYouyong Yuan
Youyong Yuan
BLBin Liu
Bin Liu

14 May 2014 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
ZXZhuolin Xiang
Zhuolin Xiang
SYShih-Cheng Yen
Shih-Cheng Yen
NXNing Xue
Ning Xue
TSTao Sun
Tao Sun
WTWei Mong Tsang
Wei Mong Tsang
Chengkuo LeeChengkuo Lee
Chengkuo Lee